Deep Learning Estimation of 10-2 Visual Field Map Based on Circumpapillary Retinal Nerve Fiber Layer Thickness Measurements - 17/01/23

Doi : 10.1016/j.ajo.2022.10.013 
Alireza Kamalipour , Sasan Moghimi , Pooya Khosravi, Mohammad Sadegh Jazayeri, Takashi Nishida, Golnoush Mahmoudinezhad, Elizabeth H. Li, Mark Christopher, Jeffrey M. Liebmann, Massimo A. Fazio, Christopher A. Girkin, Linda Zangwill, Robert N. Weinreb
 From the Hamilton Glaucoma Center (A.K., S.M., T.N., G.M., E.H.L., M.C., M.A.F., L.Z., R.N.W.), 
 Shiley Eye Institute, Viterbi Family Department of Ophthalmology, University of California San Diego, La Jolla; School of Medicine (P.K.), 
 University of California Irvine, Irvine; Department of Civil, Construction, and Environmental Engineering (M.S.J.), 
 San Diego State University, San Diego, California; Bernard and Shirlee Brown Glaucoma Research Laboratory (J.M.L.), 
 Department of Ophthalmology, Edward S. Harkness Eye Institute, Columbia University Medical Center, New York, New York; and the Department of Ophthalmology and Vision Sciences (M.A.F., C.A.G.), 
 Heersink School of Medicine, The University of Alabama at Birmingham, Birmingham, Alabama, USA. 

1Inquiries to Robert N. Weinreb, Shiley Eye Institute, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946, USAShiley Eye InstituteUniversity of California, San Diego9500 Gilman DrLa JollaCA92093-0946USA

Résumé

Purpose

To estimate central 10-degree visual field (VF) map from spectral-domain optical coherence tomography (SD-OCT) retinal nerve fiber layer thickness (RNFL) measurements in glaucoma with artificial intelligence.

Design

Artificial intelligence (convolutional neural networks) study.

Methods

This study included 5352 SD-OCT scans and 10-2 VF pairs from 1365 eyes of 724 healthy patients, patients with suspected glaucoma, and patients with glaucoma. Convolutional neural networks (CNNs) were developed to estimate the 68 individual sensitivity thresholds of 10-2 VF map using all-sectors (CNNA) and temporal-sectors (CNNT) RNFL thickness information of the SD-OCT circle scan (768 thickness points). 10-2 indices including pointwise total deviation (TD) values, mean deviation (MD), and pattern standard deviation (PSD) were generated using the CNN-estimated sensitivity thresholds at individual test locations. Linear regression (LR) models with the same input were used for comparison.

Results

The CNNA model achieved an average pointwise mean absolute error of 4.04 dB (95% confidence interval [CI] 3.76-4.35) and correlation coefficient (r) of 0.59 (95% CI 0.52-0.64) over 10-2 map and the mean absolute error and r of 2.88 dB (95% CI 2.63-3.15) and 0.74 (95% CI 0.67-0.80) for MD, and 2.31 dB (95% CI 2.03-2.61) and 0.59 (95% CI 0.51-0.65) for PSD estimations, respectively, significantly outperforming the LRA model.

Conclusions

The proposed CNNA model improved the estimation of 10-2 VF map based on circumpapillary SD-OCT RNFL thickness measurements. These artificial intelligence methods using SD-OCT structural data show promise to individualize the frequency of central VF assessment in patients with glaucoma and would enable the reallocation of resources from patients at lowest risk to those at highest risk of central VF damage.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2022  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 246

P. 163-173 - février 2023 Retour au numéro
Article précédent Article précédent
  • Leadership in Ophthalmology Professional Organizations: A Descriptive Analysis and Trends, 2002-2022
  • Rachel H. Lee, Kateki Vinod, Alana L. Grajewski
| Article suivant Article suivant
  • What Are the Dry Eye Questionnaires Available in the Scientific Literature Used for? A Scoping Review
  • Mar Sánchez-Brau, Mar Seguí-Crespo, Natalia Cantó-Sancho, Ana Tauste, José María Ramada

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.