S'abonner

The need for systematic quality controls in implementing N95 reprocessing and sterilization - 02/03/23

Doi : 10.1016/j.jhin.2022.11.023 
N. Goyal a, , D. Goldrich a, W. Hazard b, W. Stewart c, C. Ulinfun d, J. Soulier e, G. Fink f, T. Urich g, R. Bascom h
on behalf of the

N95 Taskforce

a Department of Otolaryngology – Head and Neck Surgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
b Department of Anesthesiology and Perioperative Medicine and Neurosurgery, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
c Operational Excellence Program, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
d Department of Facilities, Administration, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
e Department of Nursing, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
f Facilities Infrastructure and Energy, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
g Department of Environmental Systems, Facilities Maintenance, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 
h Department of Pulmonary Medicine, The Pennsylvania State University, College of Medicine, Hershey, PA, USA 

Corresponding author. Department of Otolaryngology Head and Neck Surgery, 500 University Drive, MC H091, Hershey, PA 17033, USA.Department of Otolaryngology Head and Neck Surgery500 University DriveMC H091HersheyPA17033USA

Summary

Background

Due to increased requirement for personal protective equipment during the coronavirus disease 2019 pandemic, many medical centres utilized sterilization systems approved under Food and Drug Administration Emergency Use Authorization for single-use N95 mask re-use. However, few studies have examined the real-world clinical challenges and the role of ongoing quality control measures in successful implementation.

Aims

To demonstrate successful implementation of quality control measures in mask reprocessing, and the importance of continued quality assurance.

Methods

A prospective quality improvement study was conducted at a tertiary care medical centre. In total, 982 3M 1860 masks and Kimberly-Clark Tecnol PFR95 masks worn by healthcare workers underwent sterilization using a vaporized hydrogen peroxide gas plasma-based reprocessing system. Post-processing qualitative fit testing (QFT) was performed on 265 masks. Mannequin testing at the National Institute for Occupational Safety and Health (NIOSH) laboratory was used to evaluate the impact of repeated sterilization on mask filtration efficacy and fit. A locally designed platform evaluated the filtration efficiency of clinically used and reprocessed masks.

Findings

In total, 255 N95 masks underwent QFT. Of these, 240 masks underwent post-processing analysis: 205 were 3M 1860 masks and 35 were PFR95 masks. Twenty-five (12.2%) of the 3M masks and 10 (28.5%) of the PFR95 masks failed post-processing QFT. Characteristics of the failed masks included mask deformation (N=3, all 3M masks), soiled masks (N=3), weakened elastic bands (N=5, three PFR95 masks), and concern about mask shrinkage (N=3, two 3M masks). NIOSH testing demonstrated that while filter efficiency remained >98% after two cycles, mask strap elasticity decreased by 5.6% after reprocessing.

Conclusions

This study demonstrated successful quality control implementation for N95 mask disinfection, and highlights the importance of real-world clinical testing beyond laboratory conditions.

Le texte complet de cet article est disponible en PDF.

Keywords : N95, Mask reprocessing, Sterilization, Pandemic, COVID-19, SARS-COV-2, Quality control, Quality improvement, Infection control, Hospital safety


Plan


© 2022  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 133

P. 38-45 - mars 2023 Retour au numéro
Article précédent Article précédent
  • Evaluation of the ability of commercial disinfectants to degrade free nucleic acid commonly targeted using molecular diagnostics
  • S. Stoufer, M. Demokritou, D. Buckley, P. Teska, M.D. Moore
| Article suivant Article suivant
  • Improving parametric load release for steam sterilization
  • Working Party on Improving Parametric Load Release for Steam Sterilization

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.