S'abonner

Comparing Outcomes Between Surgical and Transcatheter Aortic Valve Replacement in Classical Low-Flow Low-Gradient Aortic Stenosis - 09/03/23

Doi : 10.1016/j.amjcard.2023.01.020 
Kush P. Patel, MRCP a, b, Sebastian Vandermolen, MRCP a, c, Jackie Cooper, MSc a, c, Francesca Pugliese, PhD a, c, Mick Ozkor, MD a, Simon Kennon, MD a, Anthony Mathur, PhD a, d, Mohammed Y. Khanji, PhD a, c, Michael J. Mullen, MD a, b, Andreas Baumbach, FRCP, PhD a, d, Wael I. Awad, FRCS(C/Th) a, d,
a Barts Heart Center, West Smithfield, London, United Kingdom 
b Institute of Cardiovascular Science, University College London, London, United Kingdom 
c National Institute for Heart Research Barts Biomedical Research Center and Center for Advanced Cardiovascular Imaging, William Harvey Research Institute, Queen Mary University of London, United Kingdom 
d Center for Cardiovascular Medicine and Devices, William Harvey Research Institute, Queen Mary University of London and Barts Heart Centre, London, United Kingdom 

Corresponding author: Tel: 0203 765 8744; fax: xxx.

Résumé

Patients with classic low-flow low-gradient (cLFLG) aortic stenosis (AS) have a poor prognosis but still benefit from aortic valve replacement. There is a paucity of evidence to guide the choice between transcatheter aortic valve replacement (TAVR) and surgical aortic valve replacement (SAVR). This study compared procedural and midterm outcomes in patients with cLFLG AS between TAVR and SAVR. Patients with cLFLG AS, defined as an aortic valve area ≤1 cm2, mean gradient <40 mm Hg, and left ventricular ejection fraction <50%, were selected from a single center between 2015 and 2020. Inverse probability weighting and regression were used to adjust for differences in baseline characteristics, the nonrandom assignment of treatment modalities, and procedural differences. The primary end point was all-cause mortality. A total of 322 patients (220 TAVR and 102 SAVR) were included. At a follow-up of 4.4 ± 1.5 years, the adjusted hazard ratio (HR) for mortality after inverse probability weighting with SAVR was 0.66, 95% confidence interval (CI) 0.31 to 1.35; p = 0.24. Worse renal function at baseline (per 10 ml/min/m2 increase HR 0.92, 95% CI 0.84 to 1.00, p = 0.04) and multiple valve interventions (HR 5.39, 95% CI 2.62 to 11.12, p <0.001) independently predicted mortality. There was no difference in stroke and permanent pacemaker implantation, but the rates of renal replacement therapy were higher among the SAVR cohort: 13.7% versus 0%; p <0.001. In conclusion, among patients with cLFLG AS, there was no difference in midterm mortality between TAVR and SAVR, supporting the use of either treatment. However, in patients with poor renal function or at risk of renal failure, TAVR may be the preferred option.

Le texte complet de cet article est disponible en PDF.

Graphical Abstract

Summary of study methodology and results. TAVR=transcatheter aortic valve replacement, SAVR=surgical aortic valve replacement, AVA=aortic valve area, MG=mean gradient, Vmax.=transaortic peak instantaneous velocity, LVEF=left ventricular ejection fraction.



Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Plan


 Authors Kush P. Patel and Sebastian Vandermolen are joint first co-authors.
 Authors Andreas Baumbach and Wael I. Awad are joint senior co-authors.
 Funding: none.


Crown Copyright © 2023  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 192

P. 206-211 - avril 2023 Retour au numéro
Article précédent Article précédent
  • Meta-Analysis on Transcarotid Versus Transfemoral and Other Alternate Accesses for Transcatheter Aortic Valve Implantation
  • Bishoy Abraham, Mina Sous, Ramy Sedhom, Michael Megaly, Sherif Roman, John Sweeney, Mohamad Alkhouli, Peter Pollak, Abdallah El Sabbagh, Santigao Garcia, Sachin S. Goel, Marwan Saad, David Fortuin
| Article suivant Article suivant
  • Outcomes in Patients With Early Menopause Who Underwent Transcatheter Aortic Valve Implantation
  • Madison Edens, Yusuke Watanabe, Johny Nicolas, Samantha Sartori, Clayton Snyder, Birgit Vogel, Alessandro Spirito, Didier Tchetche, Anna Sonia Petronio, Julinda Mehilli, Thierry Lefèvre, Patrizia Presbitero, Piera Capranzano, Alexandra Selberg, Alessandro Iadanza, Gennaro Sardella, Nicolas M. Van Mieghem, Emanuele Meliga, Nicolas Dumonteil, Chiara Fraccaro, Daniela Trabattoni, Ghada Mikhail, Maria-Cruz Ferrer-Gracia, Christoph Naber, Samin Sharma, Marie-Claude Morice, George D. Dangas, Alaide Chieffo, Roxana Mehran

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.