S'abonner

Redo-Transcatheter Aortic Valve Implantation Using the SAPIEN 3/Ultra Transcatheter Heart Valves—Expert Consensus on Procedural Planning and Techniques - 09/03/23

Doi : 10.1016/j.amjcard.2023.01.010 
Giuseppe Tarantini, MD a, , Victoria Delgado, MD b, Ole de Backer, MD c, Janarthanan Sathananthan, MD d, Hendrik Treede, MD e, Francesco Saia, MD f, Daniel Blackman, MD g, Radoslaw Parma, MD h
a Thoracic, Vascular Sciences and Public Health, University of Padua Medical School, Padua, Italy 
b Heart Institute, Hospital Universitari Germans Trias I Pujol, Barcelona, Spain 
c The Heart Centre, Rigshospitalet, Copenhagen University Hospital, Copenhagen, Denmark 
d Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, Vancouver, British Columbia, Canada 
e Clinic and Policlinic for Heart- and Vascular Surgery, University Hospital Mainz, Mainz, Germany 
f Cardiology Unit, Cardio-Thoraco-Vascular Department, University Hospital of Bologna, Policlinico S. Orsola-Malpighi, Bologna, Italy 
g Institute of Cardiovascular and Metabolic Medicine, Leeds Teaching Hospitals NHS Trust, Leeds, United Kingdom 
h Department of Cardiology and Structural Heart Diseases, Medical University of Silesia, Katowice, Poland 

Corresponding author: Tel: +39 498212586; fax: + 39 049 8212309.

Résumé

Recent guidelines on valvular heart disease in Europe and the United States have expanded the indications for transcatheter aortic valve implantation (TAVI) to younger patients and those at lower surgical risk with severe symptomatic aortic stenosis. Consequently, the number of TAVI procedures will significantly increase worldwide. Patients with longer life expectancies will outlive their transcatheter heart valves (THVs) and require established treatment strategies for re-intervention. Current data have shown encouraging outcomes, including low mortality, with redo-TAVI; in contrast, surgical explantation of THVs is associated with high mortality. Redo-TAVI, therefore, is likely to be the treatment of choice for THV failure. The expected increase in the number of redo-TAVIs stands in contrast to the current lack of evidence on how this procedure should be planned and performed, including the risks and pitfalls operators need to consider. Preliminary reports stress the importance of preprocedural planning, understanding of THV skirt and leaflet characteristics, and implantation guidelines specific to different THVs. Currently, SAPIEN 3/Ultra is the only THV approved in Europe and the United States for redo-TAVI. Therefore, we gathered a panel of experts in TAVI procedures with the aim of providing operative guidance on redo-TAVI, using the SAPIEN 3/Ultra THV. This consensus article presents a step-by-step approach encompassing clinical, anatomical, and technical aspects in preprocedural planning, procedural techniques, and postprocedural care. In conclusion, the recommendations aim to improve the feasibility, safety, and long-term outcomes of redo-TAVI, including the durability of implanted THVs.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding was provided by Edwards Lifesciences (Nyon, Switzerland) for the meeting and for editorial support.


© 2023  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 192

P. 228-244 - avril 2023 Retour au numéro
Article précédent Article précédent
  • Outcomes in Patients With Early Menopause Who Underwent Transcatheter Aortic Valve Implantation
  • Madison Edens, Yusuke Watanabe, Johny Nicolas, Samantha Sartori, Clayton Snyder, Birgit Vogel, Alessandro Spirito, Didier Tchetche, Anna Sonia Petronio, Julinda Mehilli, Thierry Lefèvre, Patrizia Presbitero, Piera Capranzano, Alexandra Selberg, Alessandro Iadanza, Gennaro Sardella, Nicolas M. Van Mieghem, Emanuele Meliga, Nicolas Dumonteil, Chiara Fraccaro, Daniela Trabattoni, Ghada Mikhail, Maria-Cruz Ferrer-Gracia, Christoph Naber, Samin Sharma, Marie-Claude Morice, George D. Dangas, Alaide Chieffo, Roxana Mehran
| Article suivant Article suivant
  • Meta-Analysis of Cerebral Embolic Protection During Transcatheter Aortic Valve Replacement
  • Ahmad Al-Abdouh, Mohammed Mhanna, Ahmad Jabri, Taha Ahmed, Ahmed M. Altibi, Fares Ghanem, Laith Alhuneafat, Ayman Albadawi, Mahmoud Barbarawi, Nakeya Dewaswala, Huzefa Bhopalwala, Amartya Kundu, Islam Y. Elgendy

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.