S'abonner

Temporal averaging angiographic reconstructions from whole-brain CT perfusion for the detection of vasospasm - 20/04/23

Doi : 10.1016/j.neurad.2022.10.001 
Félix Gallissot a, , Marc Lenfant a, Pierre Thouant a, Karim Haioun b, Anthony Thay c, Frédéric Ricolfi a, Pierre-Olivier Comby a
a Department of Neuroradiology and Emergency Radiology, François-Mitterrand University Hospital, 14 Rue Paul Gaffarel, BP 77908, 21079 Dijon, France 
b Canon Medical Systems Corporation, Kawasaki-shi, Kanagawa, Japan 
c Canon Medical Systems France, 24 Quai Gallieni, 92150 Suresnes, France 

Corresponding author.

Abstract

Purpose

The aim of this study is to evaluate the image quality and diagnostic performance of angiographic images reconstructed from whole-brain CT perfusion (CTP) using temporal averaging compared to CT angiography (CTA) for the detection of vasospasm.

Materials and methods

39 CT studies in 28 consecutive patients who underwent brain CTA with CTP for suspected vasospasm between September 2020 and May 2021 were retrospectively evaluated. The image quality of these two vascular imaging techniques was assessed either quantitatively (image noise, vascular enhancement, signal-to-noise (SNR) and contrast-to-noise (CNR) ratios,) and qualitatively (4 criteria assessed on a 5-point scale).

Intra and interobserver agreements and a diagnostic confidence score on the diagnosis of vasospasm were measured. Radiation dose parameters (volume CT dose index (CTDIvol) and dose-length product (DLP)) were recorded.

Results

Both SNR and CNR were significantly higher with temporal averaging compared to CTA, increasing by 104% and 113%, respectively (p<0.001).

The qualitative assessment found no significant difference in overall image quality between temporal averaging (4.33 ± 0.48) and brain CTA (4.19 ± 0.52) (p = 0.12).There was a significant improvement in intravascular noise and arterial contrast enhancement with temporal averaging.

The evaluation of intra and interobserver agreements showed a robust concordance in the diagnosis of vasospasm between the two techniques.

Conclusions

Temporal averaging appeared as a feasible and reliable imaging technique for the detection of vasospasm. The use of temporal averaging, replacing brain CTA, could represent a new strategy of radiation and contrast material doses reduction in these patients.

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

Patients hospitalized for aneurysmal subarachnoid hemorrhage frequently receive a high cumulative radiation dose.
Temporal averaging reconstruction technique from brain CT perfusion appeared as an effective vascular imaging technique for the vasospasm assessment.
The use of temporal averaging instead of brain CTA could represent a new strategy of contrast agent and radiation dose reduction in patients with suspected vasospasm following subarachnoid hemorrhage.

Le texte complet de cet article est disponible en PDF.

Keywords : Brain computed tomography perfusion, Computed tomography angiography, Subarachnoid hemorrhage, Vasospasm, Temporal averaging, Image reconstruction

Abbreviation : CNR, CTA, CTDIvol, CTP, DLP, DLR, DSA, SAH, SNR


Plan


© 2022  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 50 - N° 3

P. 333-340 - mai 2023 Retour au numéro
Article précédent Article précédent
  • Value of angiographic regional circulation signs in predicting hemorrhagic transformation after endovascular thrombectomy
  • Shuai Yu, Hang Zhang, Qian-mei Jiang, Jie Hou, Zhi-liang Guo, Guo-dong Xiao
| Article suivant Article suivant
  • A novel technique for safe percutaneous biopsy of a petrous apex lesion
  • Ahmed K. Ahmed, Jacob Core, Douglas S. Fenton, Amit Desai, Vivek Gupta, Prasanna G. Vibhute

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.