S'abonner

Doppler Underestimates Transvalvular Gradient Measured by Catheterization in Patients With Severe Aortic Stenosis - 20/04/23

Doi : 10.1016/j.amjcard.2023.02.025 
Kazuaki Takamatsu, MD a, Tetsuhiro Yamano, MD a, b, , Kan Zen, MD a, Motoyoshi Takahara, MD a, Ryotaro Tani, MD a, Shunsuke Nakamura, MD a, Tomotaka Fujimoto, MD a, Masaki Yashige, MD a, Nobuyasu Ito, MD a, Michiyo Yamano, MD a, Takeshi Nakamura, MD a, Tohru Inaba, MD b, Yoko Nukui, MD b, Hitoshi Yaku, MD c, Satoaki Matoba, MD a
a Department of Cardiovascular Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan 
b Department of Infection Control and Molecular Laboratory Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan 
c Department of Cardiovascular Surgery, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan 

Corresponding author: Tel: +81 75 251 5511; fax: +81 75 251 5514.

Résumé

We sought to clarify characteristics of patients with severe aortic stenosis (AS) in whom transvalvular mean pressure gradient (MPG) was underestimated with Doppler compared with catheterization. Study subjects included 127 patients with severe AS who underwent transcatheter aortic valve implantation. Between subjects with Doppler MPG underestimation ≥10 mm Hg (group U) and those without (group C), we retrospectively compared echocardiographic parameters and aortic valve calcification score using the Agatston method. Despite a strong correlation (rS = 0.88) and small absolute difference (2.1 ± 10.1 mm Hg) between Doppler and catheter MPG, 27 patients (21%) were in group U. Among 48 patients with catheter MPG ≥60 mm Hg, 10 patients (21%) revealed Doppler MPG of 40 to 59 mm Hg, suggesting they had been misclassified as having severe AS instead of very severe AS. According to the guidelines, indication of valve replacement for patients without symptoms should be considered for very severe AS but not for severe AS. Therefore, sole reliance on Doppler MPG could cause clinical misjudgments. Group U had larger relative wall thickness (median [interquartile range: 0.60 [0.50 to 0.69] vs 0.53 [0.46 to 0.60], p = 0.003) and higher calcification score (3,024 [2,066 to 3,555] vs 1,790 [1,293 to 2,501] arbitrary units, p <0.001). Both calcification score (per 100 arbitrary unit increment, odds ratio 1.10, 1.04 to 1.17, p = 0.002) and relative wall thickness (per 0.05 increment, odds ratio 1.29, 95% confidence interval 1.05 to 1.60, p = 0.02) were independently associated with Doppler underestimation. In conclusion, Doppler might underestimate transvalvular gradient compared with catheterization in patients with severe AS who have heavy valve calcification and prominent concentric remodeling left ventricular geometry.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding: none.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 195

P. 28-36 - mai 2023 Retour au numéro
Article précédent Article précédent
  • Hemodynamic Predictors of Stabilization When Using Temporary Mechanical Support for Cardiogenic Shock from Acute on Chronic Heart Failure
  • Jonathan D. Wolfe, Elena Deych, Marc A. Sintek, Joel D. Schilling
| Article suivant Article suivant
  • Network Meta-Analysis Comparing Transcatheter, Minimally Invasive, and Conventional Surgical Aortic Valve Replacement
  • Khi Yung Fong, Jonathan J.L. Yap, Yiong Huak Chan, See Hooi Ewe, Victor T.T. Chao, Mohammed Rizwan Amanullah, Sivaraj Pillai Govindasamy, Zameer Abdul Aziz, Vern Hsen Tan, Kay Woon Ho

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.