Abstract

Background and Objectives

Tumor Treating Fields (TTFields) is an FDA-approved technique used in the treatment of glioblastoma. It consists in applying an electric field (EF) with a frequency of 200 kHz using two pairs of transducer arrays. During treatment planning, the NovoTAL system is used to strategically place the arrays on the head in regions that maximize the EF at the tumor. Current should be injected at least 18 hours/day and induce a minimum EF of 1 V/cm at the tumor. To avoid any thermal harm to the patient, the temperature of the scalp is kept around 39.5°C by changing the injected current. The goal of this study was to investigate how accounting for the temperature of the scalp during treatment planning might affect the choice of the best layout suggested by NovoTAL. Furthermore, we also studied the sensitivity of the results to the metric used to evaluate the layouts.

Methods

We used a realistic head model with a virtual glioblastoma in our studies. Through the NovoTAL system we obtained five realistic array layouts and we predicted the best one for our model based on the approach currently implemented in this system. We then repeated the same type of analysis, but also accounting for the temperature during planning. In both cases we ranked the layouts based on three different criteria: the LMiPD and the LAPD (local minimum and local average power densities, respectively) in the tumor and the SAR (specific absorption rate) in the head

Results

Accounting for the temperature does not significantly affect the choice of the best layout provided that the arrays are at least 1 cm apart from each other. Otherwise, a common temperature hotspot occurs in the scalp between the closest transducers of the adjacent arrays, which limits how much current can be injected and consequently treatment effectiveness. Also, the choice of the best layout depends on the criterion used.

Conclusions

Accounting for the temperature might led to significant variations in the current injected. The LMiPD might be used as a first criterion to choose the best treatment layout, followed by the LAPD and then the SAR.

Le texte complet de cet article est disponible en PDF.

Graphical abstract

Le texte complet de cet article est disponible en PDF.

Highlights

Accounting for scalp's temperature might reduce the current injected in simulations.
Temperature hotspots might occur between arrays if they are spaced by less than 1 cm.
Considering the temperature in planning affects the choice of which layout to use.
The choice of the best layout is sensitive to the metric chosen to evaluate it.

Le texte complet de cet article est disponible en PDF.

Keywords : Finite element method, Glioblastoma, Optune, NovoTAL system, Tissue heating, Tumor treating fields


Plan


© 2023  AGBM. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 44 - N° 3

Article 100768- juin 2023 Retour au numéro
Article précédent Article précédent
  • A Double-Needle Gold-Silver Electrodes Continuous Glucose Monitoring Device
  • C. Ben Ali Hassine, A. Tekin
| Article suivant Article suivant
  • Optimal Sensor Placement in Smart Home Using Building Information Modeling: A Home Support Application
  • R. Ben Bachouch, Y. Fousseret, Y. Parmantier

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.