Single-use versus reusable metallic laryngoscopes for non-emergent intubation: A retrospective review of 72,672 intubations - 05/07/23
, Garrett W. Burnett, M.D a
, Sophia Chiu, M.D b
, Yuxia Ouyang, Ph.D a
, Hung-Mo Lin, Sc.D c
, Jaime B. Hyman, M.D c, ⁎ 
Abstract |
Study objective |
Increased regulatory requirements for sterilization in recent years have prompted a widespread transition from reusable to single-use laryngoscopes. The purpose of this study was to determine if the transition from metallic reusable to metallic single-use laryngoscopes impacted the performance of direct laryngoscopy at an academic medical center.
Design |
Single-site retrospective cohort study.
Setting |
General anesthetic cases requiring tracheal intubation.
Patients |
Adult patients undergoing non-emergent procedures.
Interventions |
Data were collected two years before and two years after a transition from metallic reusable to metallic single-use laryngoscopes.
Measurements |
The primary outcome was need for intubation rescue with an alternate device. Secondary outcomes were difficult laryngeal view (modified Cormack-Lehane grade ≥ 2b) and hypoxemia (SpO2 < 90% for >30 s) during direct laryngoscopy intubations. Subgroup analyses for rapid sequence induction, Macintosh blades, Miller blades, and patients with difficult airway risk factors (Obstructive Sleep Apnea, Mallampati ≥3, Body Mass Index >30 kg/m2) were performed.
Main results |
In total, 72,672 patients were included: 35,549 (48.9%) in the reusable laryngoscope cohort and 37,123 (51.1%) in the single-use laryngoscope cohort. Compared with reusable laryngoscopes, single-use laryngoscopes were associated with fewer rescue intubations with an alternate device (covariates-adjusted odds ratio [OR] 0.81 95% CI 0.66–0.99). Single-use laryngoscopes were also associated with lower odds of difficult laryngeal view (OR 0.86; 95% CI 0.80–0.93). Single use laryngoscopes were not associated with hypoxemia during the intubation attempt (OR 1.03; 95% CI 0.88–1.20). Similar results were observed for subgroup analyses including rapid sequence induction, Macintosh blades, Miller blades, and patients with difficult airway risk factors.
Conclusions |
Metallic single-use laryngoscopes were associated with less need for rescue intubation with alternate devices and lower incidence of poor laryngeal view compared to reusable metallic laryngoscopes.
Le texte complet de cet article est disponible en PDF.Highlights |
• | Many healthcare institutions have switched from reusable to single-use laryngoscopes. |
• | Single-use metallic laryngoscopes were associated fewer rescue intubations in this study. |
• | Single-use metallic laryngoscopes were associated with lower odds of poor laryngeal view. |
• | These results can be considered as one factor in determining choice of laryngoscope. |
Keywords : Intubation, Direct laryngoscopy, Laryngoscope, Airway management