S'abonner

Three-Dimensional Quantitative Description of the Implantable Collamer Lens in the Ocular Anterior Segment of Patients With Myopia - 12/07/23

Doi : 10.1016/j.ajo.2023.03.005 
Tong Zhang 1, Fanfan Huang 1, Ning Gao 1, Miaomiao Du 1, Hong Cheng 1, Wanyao Huang 1, Yan Ji 2, Shijie Zheng 2, Wenjuan Wan 1, 2, , Ke Hu 1, 2, ,
1 From Chongqing Medical University (T.Z., F.H., N.G., M.D., H.C., W.H., W.W., K.H.) and The First Affiliated Hospital of Chongqing Medical University (Y.J., S.Z., W.W., K.H.), Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China. 
2 The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China. 

#Inquiries to Wenjuan Wan, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, China or Ke Hu, The First Affiliated Hospital of Chongqing Medical University, Chongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular Diseases, Chongqing, ChinaThe First Affiliated Hospital of Chongqing Medical UniversityChongqing Key Laboratory of Ophthalmology, Chongqing Eye Institute, Chongqing Branch (Municipality Division) of National Clinical Research Center for Ocular DiseasesChongqingChina

Résumé

Purpose

To describe the 3-dimensional (3D) location of the implantable collamer lens (ICL) quantitatively in the posterior ocular chamber of patients with myopia.

Design

Cross-sectional study.

Methods

To obtain visualization models before and after mydriasis, an automatic 3D imaging method based on swept-source optical coherence tomography was created. Parameters like the ICL lens volume (ILV), the tilt of the ICL and crystalline lens, the vault distribution index, and topographic maps were evaluated to describe the ICL location. Using a paired sample t test and the Wilcoxon signed rank test, the difference between nonmydriasis and postmydriasis conditions was compared.

Results

The study investigated 32 eyes from 20 patients. The 3D central vault did not differ significantly before (P = .994) or after mydriasis (P = .549) compared with the 2D central vault. After mydriasis, the 5-mm ILV decreased by 0.85 mm2 (P = .016), and the vault distribution index increased significantly (P = .001). The ICL and the crystalline lens exhibited tilt (nonmydriasis: ICL total tilt 3.78 ± 1.85 degrees, lens total tilt 4.03 ± 1.53 degrees; postmydriasis: ICL total tilt 3.84 ± 1.56 degrees, lens total tilt 4.09 ± 1.64 degrees). The phenomenon of asynchronous tilt of the ICL and lens was found in 5 eyes, leading to the spatially asymmetric distribution of the ICL–lens distance.

Conclusion

The 3D imaging technique provided exhaustive and reliable data for the anterior segment. The visualization models offered multiple perspectives on the ICL in the posterior chamber. Before and after mydriasis, the intraocular ICL position was described by the 3D parameters.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 252

P. 59-68 - août 2023 Retour au numéro
Article précédent Article précédent
  • Exploring Imaging Characteristics Associated With Disease Activity in Idiopathic Multifocal Choroiditis: A Multimodal Imaging Approach
  • Evianne L. de Groot, Ninette H. ten Dam-van Loon, Carlyn V. Kouwenberg, Joke H. de Boer, Jeannette Ossewaarde-van Norel
| Article suivant Article suivant
  • Endogenous Endophthalmitis From a Klebsiella pneumoniae Liver Abscess: The Incidence, Risk Factors, and Utility of Imaging
  • EunAh Kim, Iksoo Byon, Jae Jung Lee, Young Mi Seol, Han Jo Kwon, Sung Who Park, Ji Eun Lee

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.