S'abonner

Balloon-Expandable Versus Self-Expanding Transcatheter Aortic Valve Implantation in Patients With Small Aortic Annulus: A Meta-Analysis - 29/08/23

Doi : 10.1016/j.amjcard.2023.07.100 
Alireza Hosseinpour, MD a, Rahul Gupta, MD b, , Jahangir Kamalpour, MD a, Hamidreza Hosseinpour, MD a, Abhishek Chaturvedi, MD c, Ankit Agrawal, MD d, Nainesh C. Patel, MD b, Chirdeep Patel, MD b
a School of Medicine, Shiraz University of Medical Sciences, Shiraz, Iran 
b Lehigh Valley Heart and Vascular Institute, Lehigh Valley Health Network, Allentown, Pennsylvania 
c Pauley Heart Center, Virginia Commonwealth University School of Medicine, Richmond, Virginia 
d Department of Hospital Medicine, Cleveland Clinic, Cleveland, Ohio 

Corresponding author: Tel: 484-560-8402.

Résumé

Although transcatheter aortic valve implantation (TAVI) is considered a superior option to surgery in patients with small aortic annulus (SAA), it is not clear which type of transcatheter heart valve (THV) has better results in terms of echocardiographic hemodynamics and clinical outcomes. A random-effects meta-analysis was performed comparing balloon-expandable valves (BEVs) and self-expanding valves (SEVs) in patients with SAA who underwent TAVI regarding their impact on hemodynamic and clinical outcomes at short- and midterm follow-up. Relative risk (RR) and mean difference (MD) with 95% confidence interval (95% CI) were measured for the outcomes, as appropriate. Subgroup analyses were performed based on the generation type of devices and study designs. A total of 16 articles comprising 1 randomized trial, 3 propensity-matched studies, and 12 observational studies including 4,341 patients (1,967 in BEV and 2,374 in the SEV group) with SAA were included. The implantation of BEVs correlated with a lower indexed effective orifice area (MD −0.19 [−0.25 to −0.13]) and higher transvalvular mean pressure gradient (MD 3.91, 95% CI 2.96 to 4.87). Compared with SEVs, BEVs had increased risk of prosthesis-patient mismatch (PPM; RR 2.09, 95% CI 1.79 to 2.45) and severe PPM (RR 2.16, 95% CI 1.48 to 3.15). However, BEV had lower moderate and severe paravalvular leak (RR 0.45, 95% CI 0.29 to 0.69), risk of stroke (RR 0.57, 95% CI 0.42 to 0.76), and permanent pacemaker implantation (RR 0.63, 95% CI 0.44 to 0.91). The 1-year all-cause mortality (RR 1.13, 95% CI 0.86 to 1.49) and cardiac-related mortality (RR 1.53, 95% CI 0.24 to 9.81) were not different between the 2 groups. In conclusion, SEVs were associated with larger indexed effective orifice area and lower PPM but higher paravalvular leak. In contrast, patients with SEVs were more likely to develop stroke and required permanent pacemaker implantation. Both THVs did not show difference in terms of early and midterm all-cause and cardiac mortality. Because both types of THVs show similar results regarding mortality data, hemodynamics should be among the factors considered in decision making for patients with SAA who underwent TAVI.

Le texte complet de cet article est disponible en PDF.

Keywords : balloon-expandable valves, clinical outcomes, echocardiographic hemodynamics, meta-analysis, self-expanding valves, transcatheter aortic valve implantation


Plan


 Funding: none.
 This article is not under consideration elsewhere. An abstract has been submitted for poster presentation at the TCT conference at San Diego, California in October 2023.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 204

P. 257-267 - octobre 2023 Retour au numéro
Article précédent Article précédent
  • Clinical Outcomes in Patients Who Underwent Transcatheter Edge-to-Edge Repair for Mitral Valve Regurgitation
  • Aleksander Dokollari, Serge Sicouri, Gianluca Torregrossa, Khalid Ridwan, Roberto Rodriguez, Marco Gemelli, Ozgun Erten, Eric Gnall, Jarrett Harish, Gianluigi Bisleri, Sandra Abramson, Katie Hawthorne, Scott Goldman, William Gray, Basel Ramlawi
| Article suivant Article suivant
  • Early Safety and Performance of the Premounted Dry-Pericardium Vienna Self-Expandable Transcatheter Aortic Valve System: 30-Day Outcomes of the First-in-Human VIVA Feasibility Study
  • Kasparas Briedis, Ali Aldujeli, Remigijus Zaliunas, Rimantas Benetis

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.