Younes Belkouchi a, b, , Mathieu Lederlin c, Amira Ben Afia d, v, Clement Fabre e, Gilbert Ferretti f, Constance De Margerie g, v, Pierre Berge h, Renan Liberge i, Nicolas Elbaz j, Maxime Blain k, Pierre-Yves Brillet l, Guillaume Chassagnon m, v, Farah Cadour n, Caroline Caramella o, Mostafa El Hajjam p, Samia Boussouar q, Joya Hadchiti r, Xavier Fablet c, Antoine Khalil d, v, Alain Luciani s, w, Anne Cotten t, Jean-Francois Meder u, v, Hugues Talbot a, Nathalie Lassau b, r
a OPIS, CentraleSupelec, Inria, Université Paris-Saclay, 91190 Gif-Sur-Yvette, France 
b Laboratoire d'Imagerie Biomédicale Multimodale Paris-Saclay, BIOMAPS, UMR 1281, Université Paris-Saclay, Inserm, CNRS, CEA, 94800 Villejuif, France 
c Department of Radiology, CHU Rennes, 35000 Rennes, France 
d Department of Radiology, APHP Nord, Hôpital Bichat, 75018 Paris, France 
e Department of Radiology, Centre Hospitalier de Laval, 53000 Laval, France 
f Universite Grenobles Alpes, Service de Radiologie et Imagerie Médicale, CHU Grenoble-Alpes, 38000 Grenoble, France 
g Department of Radiology, Assistance Publique-Hôpitaux de Paris, Hôpital Saint-Louis, 75010 Paris, France 
h Department of Radiology, CHU Angers, 49000 Angers, France 
i Department of Radiology, CHU Nantes, 44000 Nantes, France 
j Department of Radiology, Hôpital Européen Georges Pompidou, AP-HP, 75015 Paris, France 
k Department of Radiology, Hopital Henri Mondor, AP-HP, 94000 Créteil, France 
l Department of Radiology, Hôpital Avicenne, Paris 13 University, 93000 Bobigny, France 
m Department of Radiology, Hopital Cochin, APHP, 75014 Paris, France 
n APHM, Hôpital Universitaire Timone, CEMEREM, 13005 Marseille, France 
o Department of Radiology, Groupe hospitalier Paris Saint-Joseph, Île-de-France, 75015 Paris, France 
p Department of Radiology, Ambroise Paré Hospital GH AP-HP Paris Saclay, UMR 1179 INSERM/UVSQ, Team 3, 92100 Boulogne-Billancourt, France 
q Sorbonne Université, APHP, Hôpital La Pitié-Salpêtrière, Unité d'Imagerie Cardiovasculaire et Thoracique (ICT), 75013 Paris, France 
r Department of Imaging, Institut Gustave Roussy, 94800 Villejuif, France 
s Medical Imaging Department, AP-HP, Henri Mondor University Hospital, 94000 Créteil, France 
t Department of Musculoskeletal Radiology, Univ. Lille, CHU Lille, MABlab ULR 4490, 59000 Lille, France 
u Department of Neuroimaging, Sainte-Anne Hospital, 75013 Paris, France 
v Université Paris Cité, 75006 Paris, France 
w INSERM, U955, Team 18, 94000 Créteil, France 

Corresponding author:

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

The SFR 2022 artificial intelligence data challenge focused on the detection and the quantification of pulmonary embolism (PE) on CT pulmonary angiography (CTPA).
The purpose was to determine if a PE was present on CTPA using artificial intelligence, in which case computing the ratio between the right and left ventricular diameters and an arterial obstruction index (Qanadli's score) was required.
This challenge revisits the vascular obstruction score, a more intuitive approach to PE severity diagnosis, and tests the generalizability of AI on large multicenter datasets.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

In 2022, the French Society of Radiology together with the French Society of Thoracic Imaging and CentraleSupelec organized their 13th data challenge. The aim was to aid in the diagnosis of pulmonary embolism, by identifying the presence of pulmonary embolism and by estimating the ratio between right and left ventricular (RV/LV) diameters, and an arterial obstruction index (Qanadli's score) using artificial intelligence.

Materials and methods

The data challenge was composed of three tasks: the detection of pulmonary embolism, the RV/LV diameter ratio, and Qanadli's score. Sixteen centers all over France participated in the inclusion of the cases. A health data hosting certified web platform was established to facilitate the inclusion process of the anonymized CT examinations in compliance with general data protection regulation. CT pulmonary angiography images were collected. Each center provided the CT examinations with their annotations. A randomization process was established to pool the scans from different centers. Each team was required to have at least a radiologist, a data scientist, and an engineer. Data were provided in three batches to the teams, two for training and one for evaluation. The evaluation of the results was determined to rank the participants on the three tasks.

Results

A total of 1268 CT examinations were collected from the 16 centers following the inclusion criteria. The dataset was split into three batches of 310, 580 and 378 C T examinations provided to the participants respectively on September 5, 2022, October 7, 2022 and October 9, 2022. Seventy percent of the data from each center were used for training, and 30% for the evaluation. Seven teams with a total of 48 participants including data scientists, researchers, radiologists and engineering students were registered for participation. The metrics chosen for evaluation included areas under receiver operating characteristic curves, specificity and sensitivity for the classification task, and the coefficient of determination r2 for the regression tasks. The winning team achieved an overall score of 0.784.

Conclusion

This multicenter study suggests that the use of artificial intelligence for the diagnosis of pulmonary embolism is possible on real data. Moreover, providing quantitative measures is mandatory for the interpretability of the results, and is of great aid to the radiologists especially in emergency settings.

Le texte complet de cet article est disponible en PDF.

Keywords : Artificial intelligence, Deep learning, Computed tomography, Pulmonary embolism, Qanadli's score

Abbreviations : AI, CT, CTPA, JFR, PE, RV/LV, SFR, SIT


Plan


© 2023  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 10

P. 485-489 - octobre 2023 Retour au numéro
Article précédent Article précédent
  • Detection of arterial phase hyperenhancement of small hepatocellular carcinoma with MRI: Comparison between single arterial and multi-arterial phases and between extracellular and hepatospecific contrast agents
  • Thomas Bouyer, Marine Roux, Sarah Jacquemin, Marco Dioguardi Burgio, Olivier Sutter, Valérie Laurent-Croisé, Julie Lonjon, Ivan Bricault, Hervé Trillaud, Agnès Rode, Christophe Aubé, Anita Paisant
| Article suivant Article suivant
  • Gadolinium K-edge angiography with a spectral photon counting CT in atherosclerotic rabbits
  • Sara Boccalini, Riham Dessouky, Pierre-Antoine Rodesch, Hugo Lacombe, Yoad Yagil, Elias Lahoud, Klaus Erhard, Bernhard Brendel, Philippe Coulon, Jean-Baptiste Langlois, Frederic Chaput, Stephane Parola, Loic Boussel, Frederic Lerouge, Salim Si-Mohamed, Philippe C. Douek

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.