S'abonner

A new compressed sensing cine cardiac MRI sequence with free-breathing real-time acquisition and fully automated motion-correction: A comprehensive evaluation - 29/10/23

Doi : 10.1016/j.diii.2023.06.005 
Benjamin Longère a, b, c, d, , Neelem Abassebay c, Christos Gkizas c, Justin Hennicaux c, Arianna Simeone c, Aimée Rodriguez Musso c, Paul Carpentier c, Augustin Coisne a, b, c, d, Jianing Pang e, Michaela Schmidt f, Solenn Toupin g, David Montaigne a, b, c, d, François Pontana a, b, c, d
a Univ. Lille, U1011–European Genomic Institute for Diabetes (EGID), 59000 Lille, France 
b Inserm, U1011, 59000 Lille, France 
c CHU Lille, Department of Cardiovascular Radiology, 59000 Lille, France 
d Institut Pasteur Lille, 59000 Lille, France 
e MR R&D, Siemens Medical Solutions USA Inc., Chicago, IL 60611, USA 
f MR Product Innovation and Definition, Healthcare Sector, Siemens GmbH, 91052 Erlangen, Germany 
g Scientific Partnerships, Siemens Healthcare France, 93200 Saint-Denis, France 

Corresponding author:

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Highlights

Motion-corrected compressed sensing cine cardiac MRI acquired during free-breathing is robust to arrhythmia and preserves image quality by averaging multiple real-time acquisitions.
Regardless of the patient's heart rhythm or ability to maintain apnea, motion-corrected compressed sensing cine cardiac MRI improves edge sharpness compared to the reference cine MRI sequence at the same spatial resolution.
With reliable assessment of left and right ventricular functional parameters and preserved image quality, this new sequence overcomes recurring cine cardiac MRI image quality issues, namely arrhythmia and shortness of breath.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The purpose of this study was to compare a new free-breathing compressed sensing cine (FB-CS) cardiac magnetic resonance imaging (CMR) to the standard reference multi-breath-hold segmented cine (BH-SEG) CMR in an unselected population.

Materials and methods

From January to April 2021, 52 consecutive adult patients who underwent both conventional BH-SEG CMR and new FB-CS CMR with fully automated respiratory motion correction were retrospectively enrolled. There were 29 men and 23 women with a mean age of 57.7 ± 18.9 (standard deviation [SD]) years (age range: 19.0–90.0 years) and a mean cardiac rate of 74.6 ± 17.9 (SD) bpm. For each patient, short-axis stacks were acquired with similar parameters providing a spatial resolution of 1.8 × 1.8 × 8.0 mm3 and 25 cardiac frames. Acquisition and reconstruction times, image quality (Likert scale from 1 to 4), left and right ventricular volumes and ejection fractions, left ventricular mass, and global circumferential strain were assessed for each sequence.

Results

FB-CS CMR acquisition time was significantly shorter (123.8 ± 28.4 [SD] s vs. 267.2 ± 39.3 [SD] s for BH-SEG CMR; P < 0.0001) at the penalty of a longer reconstruction time (271.4 ± 68.7 [SD] s vs. 9.9 ± 2.1 [SD] s for BH-SEG CMR; P < 0.0001). In patients without arrhythmia or dyspnea, FB-CS CMR provided subjective image quality that was not different from that of BH-SEG CMR (P = 0.13). FB-CS CMR improved image quality in patients with arrhythmia (n = 18; P = 0.002) or dyspnea (n = 7; P = 0.02), and the edge sharpness was improved at end-systole and end-diastole (P = 0.0001). No differences were observed between the two techniques in ventricular volumes and ejection fractions, left ventricular mass or global circumferential strain in patients in sinus rhythm or with cardiac arrhythmia.

Conclusion

This new FB-CS CMR addresses respiratory motion and arrhythmia-related artifacts without compromising the reliability of ventricular functional assessment.

Le texte complet de cet article est disponible en PDF.

Keywords : Artifacts, Image compression, Image enhancement, Image reconstruction, Magnetic resonance imaging, Cine cardiac MRI

Abbreviation : BH-SEG, CMR, ES, EDV, EF, ESV, EuroCMR, FB-CS, ICC, IQ, LV, LVM, PC-MRI, RV, SD, SV


Plan


© 2023  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 104 - N° 11

P. 538-546 - novembre 2023 Retour au numéro
Article précédent Article précédent
  • Co-registration with subtraction and color-coding or fusion improves the detection of new and growing lesions on follow-up MRI examination of patients with multiple sclerosis
  • Akim Adoum, Leila Mazzolo, Augustin Lecler, Jean-Claude Sadik, Julien Savatovsky, Loïc Duron
| Article suivant Article suivant
  • Coronary artery assessment on pre transcatheter aortic valve implantation computed tomography may avoid the need for additional coronary angiography
  • Adrien Lecomte, Aude Serrand, Lara Marteau, Baptiste Carlier, Thibaut Manigold, Vincent Letocart, Karine Warin Fresse, Jean-Michel Nguyen, Jean-Michel Serfaty

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.