S'abonner

Can particle counting replace conventional surveillance for airborne bacterial contamination assessments? A systematic review using narrative synthesis - 14/11/23

Doi : 10.1016/j.ajic.2023.05.004 
Frans Stålfelt, MSc a, , Karin Svensson Malchau, MD, PhD a, Camilla Björn, PhD b, Maziar Mohaddes, MD, PhD a, Annette Erichsen Andersson, RN, PhD c
a Department of Orthopedics, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden 
b RISE Research Institutes of Sweden, Division Materials and Production, Methodology, Textiles and Medical Technology, Gothenburg, Sweden 
c Institute of Health and Care Sciences, Sahlgrenska Academy, University of Gothenburg, Gothenburg, Sweden 

Address correspondence to Frans Stålfelt, MSc, Sahlgrenska Universitetssjukhuset Verksamhetsgemensamt Ortopedi, 431 80 Mölndal, Sweden.Sahlgrenska Universitetssjukhuset Verksamhetsgemensamt OrtopediMölndal431 80Sweden

Résumé

Background

Bacterial airborne contamination in the operating room during surgery indicates an increased risk for surgical site infection. The conventional surveillance method for bacteria in the air is by air sampling, plating, and counting of colony-forming units (CFU). Particle counting measures particles in the air, typically in sizes of 1-20 µm, and has been suggested as an alternative to CFU measurements. The primary aim was to investigate the correlation between the number of airborne CFU and particles during surgery. The secondary aim was to explore whether different ventilation settings influence the correlation between CFU and particles.

Methods

The databases Cochrane, Embase, and Medline were searched for relevant publications. Due to the heterogeneity of the data, meta-analysis was not possible and a narrative analysis was performed instead.

Results

The review included 11 studies. Two of the studies (n = 2) reported strong correlation between particles and CFU (Rp = 0.76 and Rc = 0.74). The remaining studies observed moderate correlation (n = 3), low correlation (n = 3), or no correlation (n = 3). Based on the primary results from this study, ventilation attribution to distinguish the correlation between particles and CFU had no or little contribution.

Conclusions

Due to the lack of convincing evidence of correlation and lack of high-quality studies performing measurements in a standardized way, the studies could not provide the necessary evidence that show that particle counting could be used as a substitution for conventional air bacterial assessment. Further studies are warranted to strengthen the conclusion.

Le texte complet de cet article est disponible en PDF.

Highlights

Particle counting has a low correlation with colony-forming units during surgery.
Microbial surveillance with particle counters should be used with caution.
Further research is needed to establish a strong evidence-based conclusion.

Le texte complet de cet article est disponible en PDF.

Keywords : Air sampling, Colony forming units, Microbial contamination, Operating room, Air quality


Plan


 Conflicts of interest: None to report.


© 2023  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 51 - N° 12

P. 1417-1424 - décembre 2023 Retour au numéro
Article précédent Article précédent
  • Paramedic insertion of peripheral intravenous catheters, unused catheter rates, and influencing factors: A retrospective review
  • Eleanor Golling, Nigel Barr, Thea van de Mortel, Peta-Anne Zimmerman
| Article suivant Article suivant
  • Efficacy of antimicrobial peripherally inserted central catheters in line-associated bloodstream infections: A systematic review and meta-analysis
  • Yanyan Wu, Yaqiong Liu, Bei Wang, Bilong Feng

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.