S'abonner

Modified Sling Midurethral Suspension + Hemolock Fixation Technique for Male Urinary Incontinence: A Pilot Study - 04/12/23

Doi : 10.1016/j.urology.2023.08.022 
Chen Yingxiu a, b, Song Xin a, Lv Tingting a, Huang Jin a, Cai Zhikang a, Lv Jianwei a,
a Department of Urology, Gongli Hospital of Shanghai Pudong New Area, Shanghai, China 
b Department of Urology, Hainan Western Central Hospital, Danzhou, Hainan, China 

Address correspondence to: Lv Jianwei, PhD, Department of Urology, Gongli Hospital of Shanghai Pudong Area , Pudong New Area, Miaopu Rd 219, Shanghai 200135, China.Department of Urology, Gongli Hospital of Shanghai Pudong AreaPudong New Area, Miaopu Rd 219Shanghai200135China

Résumé

Objective

To demonstrate the feasibility of a modified midurethral sling+hemolock fixation technique for treating male urinary incontinence. This study aims to provide a preliminary assessment of the short-term clinical efficacy of this technique.

Methods

We collected the clinical data of patients treated with modified sling midurethral suspension+ hemolock fixation technique. The primary evaluation criteria were surgery-related indicators and daily urinal pad usage by patients before and after treatment, and the secondary evaluation criteria were the corresponding incontinence scores and the results of surgery-related questionnaires.

Results

Follow-up 1-7months, eight patients achieved a clinical cure. Follow-up 1month after surgery showed that two patients (25.0%) used one pad daily and six patients (75.0%) did not need pads. The incontinence quality of life questionnaire (I-QOL) scores were (86.0 ± 7.0) and (89.0 ± 3.0) at three postoperative days and one postoperative month, respectively, which were significantly higher than the preoperative scores (26.0 ± 6.0) (P <.05). The scores of the International Continence Control Association Incontinence Questionnaire Short Form (ICI-Q-SF) at three postoperative days and one postoperative month were (4.0 ± 2.0) and (4.0 ± 1.0), respectively, which were significantly lower than the preoperative scores of (18.0 ± 1.0) (P <.05). Besides, the results of the surgery-related questionnaires were positive.

Conclusion

The short-term efficacy of the modified sling midurethral suspension+ hemolock fixation technique for the treatment of male urinary incontinence patients is safe, effective, minimally invasive, and has few complications. However, further validation in large samples, randomized, comparative, and longer-term follow-up studies is still needed.

Le texte complet de cet article est disponible en PDF.

Plan


 Funding Support: This study was sponsored by the Top-level Clinical Discipline Project of Shanghai Pudong (No. PWYgf 2021-06); Key Medical Specialties of Shanghai Health and Health System (ZK2019A09).
 Chen Yingxiu and Song Xin contributed equally to this work.


© 2023  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 182

P. 196-203 - décembre 2023 Retour au numéro
Article précédent Article précédent
  • The Impact of Laser Energy on Functional Outcome Following Holmium Laser Enucleation of the Prostate
  • Thilo Westhofen, Alexander Buchner, Lennert Eismann, Severin Rodler, Patrick Keller, Michael Atzler, Friedrich Jokisch, Raphaela Waidelich, Armin Becker, Christian G. Stief, Philipp Weinhold
| Article suivant Article suivant
  • Is Holmium Laser Enucleation of the Prostate Truly Size-Independent? A Critical Evaluation at the Extreme Ends of the Spectrum
  • Joao G. Porto, Ruben Blachman-Braun, Carlos Delgado, Mohamadhusni Zarli, Ryan Chen, Tarek Ajami, Robert Marcovich, Hemendra N. Shah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.