S'abonner

Deep Learning Estimation of 10-2 Visual Field Map Based on Macular Optical Coherence Tomography Angiography Measurements - 08/12/23

Doi : 10.1016/j.ajo.2023.09.014 
Golnoush Mahmoudinezhad 1, #, Sasan Moghimi 1, #, Jiacheng Cheng 2, Liyang Ru 2, Dongchen Yang 3, Kushagra Agrawal 2, Rajeev Dixit 2, Siavash Beheshtaein 4, Kelvin H. Du 1, Kareem Latif 1, Gopikasree Gunasegaran 1, Eleonora Micheletti 1, Takashi Nishida 1, Alireza Kamalipour 1, Evan Walker 1, Mark Christopher 1, Linda Zangwill 1, Nuno Vasconcelos 2, Robert N. Weinreb 1,
1 From the Hamilton Glaucoma Center (G.M., S.M., K.H.D., K.L., G.G., E.M., T.N., A.K., E.W., M.C., L.Z., R.N.W.), Shiley Eye Institute, Viterbi Family Department of Ophthalmology, UC San Diego, La Jolla, California 
2 Department of Electrical and Computer Engineering (J.C., L.R., K.A., R.D., N.V.), University of California San Diego, La Jolla, California 
3 Department of Computer Science and Engineering (D.Y.), University of California San Diego, La Jolla, California 
4 L3Harris Technologies (S.B.), Torrance, California, USA 

Inquiries to Robert N. Weinreb, Shiley Eye Institute, University of California, San Diego, 9500 Gilman Dr, La Jolla, CA 92093-0946, USAShiley Eye Institute, University of CaliforniaSan Diego, 9500 Gilman DrLa JollaCA92093-0946USA

Highlights

Deep learning models enable the estimation of visual field loss from optical coherence tomography angiography images with high accuracy.
Applying deep learning to the optical coherence tomography angiography images may enhance clinical decision making.
It may improve risk stratification of patients at risk for central visual field damage.

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

To develop deep learning (DL) models estimating the central visual field (VF) from optical coherence tomography angiography (OCTA) vessel density (VD) measurements.

Design

Development and validation of a deep learning model.

Methods

A total of 1051 10-2 VF OCTA pairs from healthy, glaucoma suspects, and glaucoma eyes were included. DL models were trained on en face macula VD images from OCTA to estimate 10-2 mean deviation (MD), pattern standard deviation (PSD), 68 total deviation (TD) and pattern deviation (PD) values and compared with a linear regression (LR) model with the same input. Accuracy of the models was evaluated by calculating the average mean absolute error (MAE) and the R2 (squared Pearson correlation coefficients) of the estimated and actual VF values.

Results

DL models predicting 10-2 MD achieved R2 of 0.85 (95% confidence interval [CI], 74-0.92) for 10-2 MD and MAEs of 1.76 dB (95% CI, 1.39-2.17 dB) for MD. This was significantly better than mean linear estimates for 10-2 MD. The DL model outperformed the LR model for the estimation of pointwise TD values with an average MAE of 2.48 dB (95% CI, 1.99-3.02) and R2 of 0.69 (95% CI, 0.57-0.76) over all test points. The DL model outperformed the LR model for the estimation of all sectors.

Conclusions

DL models enable the estimation of VF loss from OCTA images with high accuracy. Applying DL to the OCTA images may enhance clinical decision making. It also may improve individualized patient care and risk stratification of patients who are at risk for central VF damage.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.
Meeting Presentation: Presented at the Association for Research in Vision and Ophthalmology Annual Conference 2023.


© 2023  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 257

P. 187-200 - janvier 2024 Retour au numéro
Article précédent Article précédent
  • Network Meta-analysis of Intraocular Lens Power Calculation Formula Accuracy in 1016 Eyes With Long Axial Length
  • Yiyuan Ma, Ruilin Xiong, Zhenzhen Liu, Charlotte Aimee Young, Yue Wu, Danying Zheng, Xinyu Zhang, Guangming Jin
| Article suivant Article suivant
  • Comorbidity of Ocular and Facial Demodicosis
  • Wei-Lun Huang, Chang-Ming Huang, Chia-Yu Chu, Fung-Rong Hu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.