Abstract

Introduction

Innovative technologies from other fields of science are constantly being introduced in medicine. Research works on animals strongly confirm the belief in better results following ultrasound and laser surgery. The main conclusions are based on observations from different animal species, whose biological characteristics differ from those of humans. This requires scientific experiments to be performed and confirmed in humans.

Material & methods

Human mandible specimens harvested in vivo by a conventional low-speed rotary device, an ultrasonic unit, or an Er: YAG laser were studied and analyzed to compare their effects on bone morphology and tissue response following surgery.

Results

The cutting surface of eighty biopsies was studied, as well the facial edema, pain levels, and jaw dysfunction were followed up in the same eighty patients from whom the slices were obtained. In the piezosurgery and drill groups, the borders exhibited irregular edges full of bone fragments and debris. Thermal alterations within the superficial surface in all bone samples were generally minimal. In all specimens, intact osteocytes were detectable away from the area of direct action of the bone-cutting device. It was established, that the reactive facial edema, pain levels, and jaw disfunction were with milder values following in vivo osteotomy by an ultrasonic unit and Er: YAG laser compared to the conventional drilling. Moreover, the recovery of the patients in these two groups was more pronounced. The observed tissue changes proved to affect the follow-up tissue reactions in the postoperative period (p ≤ 0.05).

Discussion

Based on the established effects on human bone by its in vivo cutting, it can be concluded that laser and ultrasonic bone surgery was a superior alternative osteotomy method in humans to conventional drilling.

Le texte complet de cet article est disponible en PDF.

Keywords : Histology, Osteotomy, Postoperative period


Plan


 The material described has not been under publication or consideration for publication elsewhere.
 All participants in the research signed an informed consent. The design of the study was approved by the Ethical Committee of the Medical University under Protocol № 3/30.04.2015.
 This research did not receive any specific grant from funding agencies in the public, commercial, or not-for-profit sectors.
 All participants in the research signed an informed consent. The design of the study was approved by the Ethical committee by the Medical University under Protocol № 3/30.04.2015.
 Supplementary elements: none


© 2023  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 125 - N° 5

Article 101750- octobre 2024 Retour au numéro
Article précédent Article précédent
  • Postoperative infections after sinus lifts and onlay grafts in penicillin allergic patients
  • Mehdi Boussaïd, Mickael Samama, Jean Philippe Foy, Alexandre Bleibtreu, Chloé Bertolus, Timothée Gellee
| Article suivant Article suivant
  • Submental island flap versus supraclavicular island flap in oral tongue cancer reconstruction: Perioperative and functional outcomes
  • Hanpon Klibngern, Tapanut Ariyanon, Donyarat Ruenmarkkaew, Sasipim Chaisawad, Pichit Sittitrai

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.