S'abonner

Reproductibilité intra et inter-évaluateur du Functional Movement Screen pour des rugbymen amateurs - 11/02/24

Intra-, inter-rater reproducibility of the Functional Movement Screen for amateur rugby players

Doi : 10.1016/j.kine.2024.01.015 
Guillaume Galliou a, b, , Bastien Agullo c
a Kiné Caen Sud, 41, avenue Père Charles de Foucauld, 14000 Caen, France 
b Centre de recherches sur la cognition et l’apprentissage, CNRS–université de Poitiers, Bât A5–TSA 21103, 5, rue Théodore-Lefebvre, 86073 Poitiers cedex 9, France 
c Cabinet de kinésithérapie, 1, bis Rte de Sainte-Marguerite, 27190 Conches-en-Ouche, France 

Auteur correspondant : Kiné Caen Sud, 41, avenue Père Charles de Foucauld, 14000 Caen, France.Kiné Caen Sud41, avenue Père Charles de FoucauldCaen14000France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Sunday 11 February 2024
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Résumé

Introduction

Le rugby est devenu au fil des ans un des sports les plus populaires ; en témoigne l’engouement autour de la dernière Coupe du monde en France. Il s’agit cependant d’un sport qui demande des efforts physiques intenses et peut occasionner des blessures. Repérer ces blessures chez le joueur amateur nécessite un outil de dépistage. Ceci peut être réalisé à l’aide du Functional Movement Screen (FMS). L’objectif principal de cette étude était de déterminer la reproductibilité intra- et inter-évaluateur de ce test chez les joueurs de rugby amateurs. L’objectif secondaire de l’étude était d’évaluer les aptitudes du test comme outil prédictif de dépistage des éventuelles blessures pendant une saison sportive.

Méthode

Des rugbymen amateurs (n=61) ont réalisé les sept mouvements nécessaires à l’établissement du score du Functional Movement Screen sous la surveillance de deux évaluateurs : la comparaison des scores servait à évaluer la reproductibilité inter-évaluateur. Quarante d’entre eux ont repassé le test une semaine plus tard pour évaluer la reproductibilité intra-évaluateur, en comparant les scores de chaque joueur à différents moments par le même évaluateur. Des coefficients intraclasses ont été utilisés pour déterminer les reproductibilités. Les blessures de chaque joueur étaient comptabilisées et mises en relation avec les scores du test via un coefficient de Spearman.

Résultats

La reproductibilité inter-évaluateur du score composite du test était de bonne qualité ; la reproductibilité intra-évaluateur était de bonne qualité. Du fait d’une trop faible survenue d’évènements « blessures », il n’a pas été possible d’évaluer le test comme outil de dépistage des blessures.

Conclusion

Le Functional Movement Screen est un instrument reproductible, facile d’utilisation. Il ne peut cependant pas être considéré actuellement comme un instrument de dépistage des blessures dans le rugby amateur.

Niveau de preuve

5.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

Over the years, rugby has become one of the most popular sports, as evidenced by the excitement surrounding the last World Cup in France. However, it is a sport requiring intense physical effort and can cause injuries. Identifying these injuries in amateur players requires a screening tool. This will be the Functional Movement Screen. The main objective was to determine the intra- and inter-rater reproducibility of the test in amateur rugby players. The study's secondary objective was to evaluate the capabilities of the test as a predictive tool for screening possible injuries during a sports season.

Method

Amateur rugby players (n=61) performed the seven movements necessary to establish the test score under supervision of two evaluators: the comparison of scores was used to assess inter-rater reproducibility. Fourty of them took the test again a week later to assess intra-rater reproducibility, by comparing each player's scores at different times by the same evaluator. Intraclass coefficients were used to determine reproducibility. The injuries of each player were counted and linked to the test scores via Spearman coefficient.

Results

The inter-rater reproducibility of the test composite score was good; the intra-rater reproducibility of the test composite score was good. With a low occurrence of “injury” events, evaluating the test in our study as an injury screening tool was not possible.

Conclusion

The Functional Movement Screen is a reproducible, easy-to-use instrument. However, it cannot currently be seen as an injury screening instrument in amateur rugby.

Level of evidence

5.

Le texte complet de cet article est disponible en PDF.

Mots clés : Dépistage des blessures, Functional movement screen, Reproductibilité inter-évaluateur, Reproductibilité intra-évaluateur, Rugby

Keywords : Injury screening tool, Functional movement screen, Inter-rater reproducibility, Intra-rater reproducibility, Rugby


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2024 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.