S'abonner

Electrocardiogram Parameters Associated With the Diagnosis of Pulmonary Hypertension in High-Altitude Tibetan Populations: A Retrospective Single-Centre Study - 08/03/24

Doi : 10.1016/j.hlc.2023.10.020 
Ruimin Dong, PhD a, , Yu’en Liang, BS b, Ma Ni, BS c, Dengdi Wang, BS c, Juan Zhang, BS d, Zhu Dun, BS e,
a Department of Cardiology, the Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China 
b Electrocardiogram Room, the Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, China 
c Electrocardiogram Room, Chaya County People's Hospital, Changdu, Tibet, China 
d Department of Internal Medicine, Chaya County People's Hospital, Changdu, Tibet, China 
e Department of Surgery, Chaya County People's Hospital, Changdu, Tibet, China 

Corresponding authors at: Department of Cardiology, the Third Affiliated Hospital of Sun Yat-sen University, Guangzhou, ChinaDepartment of Cardiologythe Third Affiliated Hospital of Sun Yat-sen UniversityGuangzhouChinaDepartment of Surgery, Chaya County People's Hospital, Chaya County, Changdu, Tibet, ChinaChaya County People's HospitalChaya CountyChangduTibetChina

Abstract

Background

Electrocardiogram (ECG) is a commonly used diagnostic method for pulmonary hypertension (PH) in Tibetan areas, but its sensitivity and specificity are not good enough. This study aimed to investigate the ECG parameters associated with the diagnosis of PH in Tibetan areas.

Methods

Ninety-four PH patients of Tibetan ethnicity who were treated at the hospital between March 2019 and October 2020, and 52 Tibetan individuals as controls, were included. The ECG parameters were compared between groups. Multivariate logistic analysis was performed to identify the ECG parameters that can be used for the diagnosis of PH. The univariate significances of ECG parameters were included in the multivariate analyses, whereas those exhibiting opposite trends between different PH subtypes were excluded.

Results

Two ECG parameters were significant in multivariate analysis. The final model included S wave amplitude in lead V3 (OR 5.81; 95% CI 2.79–12.11; p<0.001) and a negative T wave in leads V1–V3 (OR 0.05; 95% CI 0.01–0.41; p=0.005). The ROC curve analysis on the final model yielded an AUC of 0.830 (95% CI 0.766–0.894; p<0.001), indicating good diagnostic performance. A nomogram for diagnosis of PH was also established using S wave amplitude in lead V3 and a negative T wave in leads V1–V3.

Conclusion

The ECG parameters S wave amplitude in lead V3 and a negative T wave in leads V1–V3 were independent factors associated with the diagnosis of PH in high-altitude Tibetan populations.

Le texte complet de cet article est disponible en PDF.

Keywords : Pulmonary hypertension, Left heart disease, Electrocardiogram parameters, Diagnostic factors, Tibet


Plan


© 2023  Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 33 - N° 2

P. 240-250 - février 2024 Retour au numéro
Article précédent Article précédent
  • Aldehyde Dehydrogenase 2 (ALDH2) rs671 Polymorphism is a Predictor of Pulmonary Hypertension Due to Left Heart Disease
  • Chao Tang, Fei Shi, Yanjing Ji, Jing Zhu, Xiaosong Gu
| Article suivant Article suivant
  • Ultrasound-mediated HGF Gene Microbubbles Mitigate Hyperkinetic Pulmonary Arterial Hypertension in Rabbits
  • Chuanzhen Liu, Xin Lv, Xiangjin Kong, Lingwei Meng, Kaiming Wei, Ruyuan Wei, Mengmeng Tang, Jianhua Li, Guangqing Cao

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.