S'abonner

A strategy combining endoscopic hand-suturing with clips for closure of rectal defects after endoscopic submucosal dissection with or without myectomy (with video) - 18/03/24

Doi : 10.1016/j.gie.2023.11.015 
Shibo Song, MD, Lizhou Dou, MM, Yong Liu, MD, Yueming Zhang, MD, Shun He, MD , Guiqi Wang, MD
 Department of Endoscopy, National Cancer Center/National Clinical Research Center for Cancer/Cancer Hospital, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China 

Reprint requests: Guiqi Wang, MD.Shun He, MD.

Abstract

Background and Aims

Endoscopic hand-suturing (EHS) has been preliminarily demonstrated to be effective in closing defects after endoscopic submucosal dissection (ESD), but it is not easily performed. We proposed a strategy combining EHS with clips (EHS-Clips) and explored its effectiveness in closing rectal defects after ESD or ESD with myectomy (ESD-ME).

Methods

In this observational study, data from patients with rectal defects closed using EHS-Clips were reviewed. EHS-Clips refers to a strategy where defects are sutured as much as possible by EHS first, with clips being used to close the remaining parts of defects that cannot be completely sutured. The primary endpoints included complete closure rate, delayed bleeding (DB) rate, and sustained closure rate. Logistic regression analyses were performed to identify risk factors for the sustained closure.

Results

All 49 (100%) defects (42 ESD defects and 7 ESD-ME defects) were completely closed through the strategy of EHS-Clips, with 35 (71.4%) through EHS alone and 14 (28.6%) through EHS and additional clips. No patients experienced DB. Thirty-six (73.5%) defects remained sustained closure on postoperative days 3 to 5 (73.8% for ESD defects vs 71.4% for ESD-ME defects). The multivariate analyses identified a stitch margin of ≥5 mm (hazard ratio, 0.313; 95% confidence interval, 0.023-0.781; P = .009) as the only independent advantage factor for the sustained closure.

Conclusions

EHS-Clips can be used to effectively close the rectal defects after ESD or ESD-ME and prevent DB. Complete suture with a stitch margin of ≥5 mm may achieve more reliable sustained closure.

Le texte complet de cet article est disponible en PDF.

Abbreviations : AE, CI, DB, EHS, EHS-Clips, ESD, ESD-ME, HR, PECS, POD, SMT, VAS


Plan


 DIVERSITY, EQUITY, AND INCLUSION: We worked to ensure gender balance in the recruitment of human subjects. We worked to ensure ethnic or other types of diversity in the recruitment of human subjects. We worked to ensure that the language of the study questionnaires reflected inclusion. The author list of this paper includes contributors from the location where the research was conducted who participated in the data collection, design, analysis, and/or interpretation of the work.
 Drs Song, Dou, and Liu are co-first authors of this work. Drs Wang and He are co-corresponding authors of this work.


© 2024  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 99 - N° 4

P. 614 - avril 2024 Retour au numéro
Article précédent Article précédent
  • Colonic-enteric lumen-apposing metal stents: a promising and safe alternative for endoscopic management of small-bowel obstruction
  • Shuji Mitsuhashi, Faisal Kamal, Brianna J. Shinn, Divya Chalikonda, Amy Tyberg, Haroon Shahid, Avik Sarkar, Michel Kahaleh, Austin Chiang, Anand Kumar, Alex Schlachterman, David Loren, Thomas Kowalski
| Article suivant Article suivant
  • Top tips for endoscopic retrograde appendicitis therapy (with video)
  • Bing-Rong Liu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.