S'abonner

Differences Between Keratometry and Total Keratometry Measurements in a Large Dataset Obtained With a Modern Swept Source Optical Coherence Tomography Biometer - 28/03/24

Doi : 10.1016/j.ajo.2023.12.003 
Jascha A. Wendelstein 1, 2, 3, 4, , Peter C. Hoffmann 5, Kenneth J. Hoffer 6, 7, Achim Langenbucher 4, Oliver Findl 8, Manuel Ruiss 8, Matthias Bolz 2, 3, Kamran M. Riaz 9, Seth M. Pantanelli 10, Guillaume Debellemanière 11, Damien Gatinel 11, David L. Cooke 12, 13, Alice Galzignato 14, Tun Kuan Yeo 15, Theo G. Seiler 1, 16, 17, Martin Zinkernagel 16, Giacomo Savini 18
1 From the Institut für Refraktive und Ophthalmo-Chirurgie (IROC) (J.A.W., T.G.S.), Zurich, Switzerland 
2 Department for Ophthalmology and Optometry (J.A.W., M.B.), Kepler University Hospital GmbH, Linz, Austria 
3 Johannes Kepler University Linz (J.A.W., M.B.), Linz, Austria 
4 Institute of Experimental Ophthalmology (J.A.W., A.L.), Saarland University, Homburg, Germany 
5 Augen-und Laserklinik (P.C.H.), Castrop-Rauxel, Germany 
6 Stein Eye Institute (K.J.H.), University of California, Los Angeles, California, CA, USA 
7 St. Mary's Eye Center (K.J.H.), Santa Monica, California, CA, USA 
8 Department of Ophthalmology (O.F., M.R.), Hanusch Hospital, Vienna Institute for Research in Ocular Surgery (VIROS), Vienna, Austria 
9 Dean A. McGee Eye Institute, University of Oklahoma (K.M.R.), Oklahoma City, OK, USA 
10 Department of Ophthalmology (S.M.P.), Penn State College of Medicine, Hershey, PA, USA 
11 Rothschild Foundation Hospital (G.D., D.G.), Department of Ophthalmology, Paris, France 
12 Great Lakes Eye Care (D.L.C.), Saint Joseph, MI, USA 
13 Department of Neurology and Ophthalmology (D.L.C.), Michigan State University, College of Osteopathic Medicine, East Lansing, MI, USA 
14 Studio Oculistico d'Azeglio (A.G.), Bologna, Italy 
15 Tan Tock Seng Hospital (T.K.Y.), Department of Ophthalmology, Singapore, Singapore 
16 Inselspital Bern (T.G.S., M.Z.), Universitätsklinik für Augenheilkunde, Bern, Switzerland 
17 Klinik für Augenheilkunde (T.G.S.), Universitätsklinikum Düsseldorf, Duesseldorf, Germany 
18 IRCCS – Fondazione Bietti (G.S.), Rome, Italy 

Inquiries to Jascha Wendelstein, IROC – Institut für Refraktive- und Ophthalmo-Chirurgie Zürich, Stockerstrasse 37, CH-8002 Zürich, Switzerland; Department for Ophthalmology and Optometry, Kepler University Hospital GmbH, Krankenhausstrasse 9, 4020 Linz, Austria; Medical Faculty, Johannes Kepler University Linz, Altenberger Strasse 69, 4040 Linz, Austria; Tel.: +43 (0)5 7680 83 – 1048, Fax: +43 (0)5 7680 83 – 1822IROC – Institut für Refraktive- und Ophthalmo-Chirurgie Zürich, Stockerstrasse 37, CH-8002 Zürich, Switzerland; Department for Ophthalmology and Optometry, Kepler University Hospital GmbH, Krankenhausstrasse 9, 4020 Linz, AustriaMedical FacultyJohannes Kepler University LinzAltenberger Strasse 69Linz4040Austria

Résumé

Purpose

This study aimed to explore the concept of total keratometry (TK) by analyzing extensive international datasets representing diverse ethnic backgrounds. The primary objective was to quantify the disparities between traditional keratometry (K) and TK values in normal eyes and assess their impact on intraocular lens (IOL) power calculations using various formulas.

Design

Retrospective multicenter intra-instrument reliability analysis.

Methods

The study involved the analysis of biometry data collected from ten international centers across Europe, the United States, and Asia. Corneal power was expressed as equivalent power and astigmatic vector components for both K and TK values. The study assessed the influence of these differences on IOL power calculations using different formulas. The results were analyzed and plotted using Bland–Altman and double angle plots.

Results

The study encompassed a total of 116,982 measurements from 57,862 right eyes and 59,120 left eyes. The analysis revealed a high level of agreement between K and TK values, with 93.98% of eyes exhibiting an absolute difference of 0.25 D or less. Astigmatism vector differences exceeding 0.25 D and 0.50 D were observed in 39.43% and 1.08% of eyes, respectively.

Conclusions

This large-scale study underscores the similarity between mean K and TK values in healthy eyes, with rare clinical implications for IOL power calculation. Noteworthy differences were observed in astigmatism values between K and TK. Future investigations should delve into the practicality of TK values for astigmatism correction and their implications for surgical outcomes.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2023  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 260

P. 102-114 - avril 2024 Retour au numéro
Article précédent Article précédent
  • Retinoblastoma Outcomes in the Americas: A Prospective Analysis of 491 Children With Retinoblastoma From 23 American Countries
  • Jesse L. Berry, Sarah Pike, Archeta Rajagopalan, Mark W. Reid, Ido Didi Fabian, Global Retinoblastoma Study Group, Armin R. Afshar, Amanda Alejos, Ernesto Alemany-Rubio, Yvania Alfonso Carreras, Mattan Arazi, Nicholas J. Astbury, Covadonga Bascaran, Elaine Binkley, Sharon Blum, H. Culver Boldt, Maria Teresa B.C. Bonanomi, Richard Bowman, Rachel C. Brennan, Matthew J. Burton, Patricia Calderón-Sotelo, Doris A. Calle Jara, Miriam R. Cano, Luis Castillo, Isabel Cavieres, Doris Quiroz Cerna, Arthika Chandramohan, Guillermo L. Chantada, Timothy W. Corson, Kristin E. Cowan-Lyn, Jacquelyn M. Davanzo, Hakan Demirci, Rosdali Y. Diaz Coronado, Helen Dimaras, Carla R. Donato Macedo, Connor Ericksen, Adriana C. Fandiño, Delia D.P.G. Fernández, Allen Foster, Ligia D. Fu, Soad L. Fuentes-Alabi, Juan L. Garcia, Henry N. Garcia Pacheco, Ana V. Girón, Marco A. Goenz, Aaron S. Gold, Nir Gomel, Efren Gonzalez, Graciela Gonzalez Perez, Liudmira González-Rodríguez, Jaime Graells, Nathalia D.A.K. Grigorovski, Patrick Hamel, Eric D. Hansen, J. William Harbour, M. Elizabeth Hartnett, Muhammad Hassan, G. Baker Hubbard, Noa Kapelushnik, Jonathan W. Kim, Scott A. Larson, Kelly D. Laurenti, Amy A. Leverant, Cairui Li, Juan P. López, Sandra Luna-Fineman, George N. Magrath, Ashwin Mallipatna, Clarissa C.D.S. Mattosinho, Marilyn B. Mets, Audra Miller, Prithvi Mruthyunjaya, Timothy G. Murray, Scott C.N. Oliver, Joaquin Oporto, Miriam Ortega-Hernández, Diego Ossandon, Claudia R. Pascual Morales, Katherine E. Paton, David A. Plager, Rodrigo A. Polania, Jimena Ponce, D. Karina Quintero, Aparna Ramasubramanian, Marco A. Ramirez-Ortiz, Jasmeen K. Randhawa, Livia Romero, Beatriz Salas, Gissela L. Sánchez, Alma Janeth Sanchez Orozco, Mariana Sgroi, Ankoor S. Shah, Carol L. Shields, Arun D. Singh, Alison H. Skalet, Andrew W. Stacey, Erin D. Stahl, Caron Strahlendorf, Maria Estela Coleoni Suarez, Rosanne Superstein, Fanny F. Tarrillo Leiva, Luiz F. Teixeira, Ogul E. Uner, Jacqueline Karina Vasquez Anchaya, Leon O. Vaughan, Victor M. Villegas, Matthew W. Wilson, Antonio Yaghy, Roberto I. Yee, Arturo M. López, Marcia Zondervan
| Article suivant Article suivant
  • Comparison of Eye Tracking and Teller Acuity Cards for Visual Acuity Assessment in Pediatric Cortical/Cerebral Visual Impairment
  • Melinda Y. Chang, Mark S. Borchert

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.