S'abonner

Reproductibilité des systèmes de classifications de Mayo et Schatzker dans les fractures de l’extrémité proximale de l’ulna - 29/03/24

Reproducibility of the Mayo and Schatzker classification systems in proximal ulna fractures

Doi : 10.1016/j.rcot.2024.01.006 
Fabio Carminati , Laurent Obert, François Saade, Camille Bouteille, Edouard Woussen, Zouhair Aouzal, Michaël Bourgeois, Harrison Haight, Inès Regas-Guerzider, Séverin Rochet, Daniel Lepage, Patrick Garbuio, François Loisel
 Hôpital Jean-Minjoz, service de chirurgie orthopédique et traumatologique, chirurgie plastique, esthétique et reconstructrice, chirurgie de la main, Besançon, France 

Fabio Carminati, Hôpital Jean-Minjoz, service de chirurgie orthopédique et traumatologique, chirurgie plastique, esthétique et reconstructrice, chirurgie de la main, Besançon, France.Hôpital Jean-Minjoz, service de chirurgie orthopédique et traumatologique, chirurgie plastique, esthétique et reconstructrice, chirurgie de la mainBesançonFrance

Résumé

Introduction

La classification des fractures doit permettre une communication fiable et reproductible entre différents intervenants. Il doit s’agir d’un système logique et compréhensible ne conduisant pas à un trop grand nombre de catégories à maîtriser. L’objectif de cette étude est de déterminer la fiabilité intra- et inter-examinateur des classifications de Schatzker et Mayo dans l’analyse des fractures de l’ulna proximal.

Matériel et méthode

Nous avons réalisé une étude intra-observateur et inter-observateur sur 39 radiographies de coudes lésés tirés au sort parmi 74 cas utilisés dans une série pour l’analyse des facteurs prédictifs d’arthrose huméro-ulnaire dans les fractures de l’ulna proximal. Dix relecteurs ont réalisé chacun 2 lectures de ces examens espacées de trois mois. À chaque lecture, nous avons analysé le type lésionnel de la fracture selon les classifications de Schatzker et Mayo. Les fiabilités inter- et intra-observateur ont été mesurées à l’aide des coefficients Kappa de Cohen et Fleiss.

Résultats

La classification de Schatzker pour le premier temps d’évaluation possède une concordance inter-observateur passable (Schatzker T1, к Fleiss : 0,394), tout comme le deuxième temps d’évaluation (Schatzker T2, к Fleiss : 0,351). Le coefficient de concordance intra-observateur moyen entre les 10 évaluateurs pour la classification de Schatzker est évalué comme bon (0,61). La classification de Mayo pour le premier temps d’évaluation possède une concordance inter-observateur passable (Mayo T1, к Fleiss : 0,278), tout comme le deuxième temps d’évaluation (Mayo T2, к Fleiss : 0,292). Le coefficient de concordance intra-observateur moyen entre les 10 évaluateurs pour la classification de Mayo est évalué comme moyen (0,52).

Discussion

Les classifications des fractures de l’ulna proximal semblent être peu reproductibles entre différents observateurs puisqu’elles possèdent un coefficient de concordance inter-observateur peu élevé. Néanmoins, leur utilisation reste fiable puisque le coefficient intra-observateur mesuré est considéré comme bon.

Niveau de preuve

IV ; rétrospective.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

A fracture classification system should provide a reliable and reproducible means of communication between different parties. It should be logical and understandable, with few categories to memorize. The aim of this study was to determine the intra- and interobserver reliability of the Schatzker and Mayo classification systems for the assessment of proximal ulna fractures.

Materials and methods

Intra- and interobserver reliability studies were conducted on 39 X-rays of injured elbows drawn randomly from 74 cases previously used in a series on predictors of ulnohumeral osteoarthritis in proximal ulna fractures. Ten observers independently reviewed these X-rays on 2 separate occasions 3 months apart. The fracture type was assessed according to the Schatzker and Mayo classification systems during each reading session. Cohen's and Fleiss’ Kappa were used to measure the intra- and interobserver reliability.

Results

The Schatzker classification had a fair interobserver reliability for the first (Schatzker R1, Fleiss’ к: 0.394) and second (Schatzker R2, Fleiss’ к: 0.351) readings. The mean intraobserver reliability value between the 10 reviewers for the Schatzker classification was rated as substantial (0.61). The Mayo classification had a fair interobserver reliability for the first (Mayo R1, Fleiss’ к: 0.278) and second (Mayo R2, Fleiss’ к: 0.292) readings. The mean intraobserver reliability value between the 10 reviewers for the Mayo classification was rated as fair (0.52).

Discussion

The classification systems for proximal ulna fractures showed poor reproducibility between the different observers since they had low interobserver agreement values. Nevertheless, their use remained reliable since the measured intraobserver agreement value was deemed substantial.

Level of evidence

IV; retrospective.

Le texte complet de cet article est disponible en PDF.

Mots clés : Coude, Schatzker, Mayo, Classifications, Ulna proximal, Concordance

Keywords : Elbow, Schatzker, Mayo, Classifications, Proximal ulna, Reliability


Plan


 Ne pas utiliser, pour citation, la référence française de cet article, mais celle de l’article original paru dans Orthopaedics & Traumatology: Surgery & Research, en utilisant le DOI ci-dessus.


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 2

P. 327-335 - avril 2024 Retour au numéro
Article précédent Article précédent
  • Mesure de la force isométrique du triceps sural après réparation à ciel ouvert d’une rupture du tendon d’Achille par dispositif portatif : étude rétrospective à propos de 30 sportifs de loisir au recul minimal de 1 an
  • Marc Saab, Romain Derousseaux, Julien Beldame, Christophe Chantelot, Eric Laboute, Carlos Maynou
| Article suivant Article suivant
  • Épidémiologie des actes de traumatologie des membres en France : état des lieux et projections
  • Roger Erivan, Nicolas Carrie, Stéphane Descamps, Thomas Caputo, Stéphane Boisgard, Guillaume Villatte

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.