S'abonner

Predicted prosthesis–patient mismatch and long-term clinical outcomes after transcatheter aortic valve replacement: A SWEDEHEART study - 23/08/24

Doi : 10.1016/j.ahj.2024.07.009 
Emma Ellfors, MD a, b, ⁎ , Michael Dismorr, MD, PhD b, c, Andreas Rück, MD, PhD d, e, Magnus Settergren, MD, PhD d, e, Ulrik Sartipy, MD, PhD b, c, Natalie Glaser, MD, PhD a, b
a Department of Cardiology, Stockholm South General Hospital, Stockholm, Sweden 
b Department of Molecular Medicine and Surgery, Karolinska Institutet, Stockholm, Sweden 
c Department of Cardiothoracic Surgery, Karolinska University Hospital, Stockholm, Sweden 
d Department of Cardiology, Karolinska University Hospital, Stockholm, Sweden 
e Department of Medicine, Karolinska Institutet, Stockholm, Sweden 

⁎Reprint requests: Emma Ellfors, MD, Department of Molecular Medicine and Surgery, Karolinska Institutet, 171 77 Stockholm, Sweden.Department of Molecular Medicine and SurgeryKarolinska InstitutetStockholm171 77Sweden

ABSTRACT

Background

The impact of prosthesis–patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) is uncertain. This study was performed to investigate the risk of all-cause mortality, heart failure hospitalization, and aortic valve reintervention in patients with and without predicted PPM after TAVR.

Methods

This nationwide, population-based cohort study included all patients who underwent transfemoral primary TAVR in Sweden from 2008 to 2022 in the SWEDEHEART register. PPM was defined according to published effective orifice areas for each valve model and size. The patients were divided into those with and without PPM. Additional baseline characteristics and outcome data were obtained from other national health data registers. Regression standardization was used to adjust for intergroup differences.

Results

Of 8485 patients, 7879 (93%) had no PPM and 606 (7%) had PPM. The crude cumulative incidence of all-cause mortality at 1, 5, and 10 years in patients with versus without PPM was 7% versus 9%, 40% versus 44%, and 80% versus 85%, respectively. After regression standardization, there was no between-group difference in long-term mortality, and the absolute difference at 10 years was 1.5% (95% confidence interval, −2.9%-6.0%). The mean follow-up was 3.0 years (maximum, 14 years). There was no difference in the risk of heart failure hospitalization or aortic valve reintervention.

Conclusions

The risk of all-cause mortality, heart failure hospitalization, or aortic valve reintervention was not higher in patients with than without predicted PPM following TAVR. Furthermore, PPM was present in only 7% of patients, and severe PPM was almost nonexistent.

Le texte complet de cet article est disponible en PDF.

Graphical Abstract




Image, graphical abstract

Le texte complet de cet article est disponible en PDF.

Plan


 Short tweet: Results from the #SWEDEHEART registry: The risk of all-cause mortality, heart failure hospitalization, or aortic valve reintervention was not higher in patients with than without predicted prosthesis-patient mismatch following #TAVR. #PPM


© 2024  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 276

P. 70-82 - octobre 2024 Retour au numéro
Article précédent Article précédent
  • Sarcopenia and frailty in patients undergoing transcatheter aortic valve replacement
  • Ian Persits, Saeid Mirzai, Kunaal S. Sarnaik, Maximilian C. Volk, James Yun, Serge Harb, Rishi Puri, Samir Kapadia, Amar Krishnaswamy, Po-Hao Chen, Grant Reed, W. H. Wilson Tang
| Article suivant Article suivant
  • Cardiovascular event reduction among a US population eligible for semaglutide per the SELECT trial
  • Jay B. Lusk, LáShauntá Glover, Samir Soneji, Christopher B. Granger, Emily O'Brien, Neha Pagidipati

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.