S'abonner

Architectural interventions to mitigate the spread of SARS-CoV-2 in emergency departments - 28/08/24

Doi : 10.1016/j.jhin.2024.05.019 
G. Hernandez-Mejia a, , S. Scheithauer b, S. Blaschke c, N. Kucheryava b, K. Schwarz b, J. Moellmann d, D.V. Tomori a, A. Bartz a, V.K. Jaeger a, B. Lange e, A. Kuhlmann f, g, J. Holzhausen d, A. Karch a
a Institute of Epidemiology and Social Medicine, University of Münster, Münster, Germany 
b Institute of Infection Control and Infectious Diseases, University Medical Center Göttingen, University of Göttingen, Germany 
c Central Emergency Department, University Medical Center Göttingen, Göttingen, Germany 
d Institute of Construction Design, Industrial and Health Care Building, Technical University of Braunschweig, Braunschweig, Germany 
e Department of Epidemiology, Helmholtz Centre for Infection Research, Braunschweig, Germany 
f Faculty of Medicine, Martin Luther University Halle-Wittenberg, Halle (Saale), Germany 
g Biomedical Research in End-Stage and Obstructive Lung Disease Hannover (BREATH), German Center for Lung Research (DZL), Hanover, Germany 

Corresponding author. Address: Institute of Epidemiology and Social Medicine, University of Münster, Domagkstraße 3, 48149 Münster, Germany.Institute of Epidemiology and Social MedicineUniversity of MünsterDomagkstraße 3Münster48149Germany

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Summary

Introduction

Emergency departments (EDs) are a critical entry gate for infectious agents into hospitals. In this interdisciplinary study, we explore how infection prevention and control (IPC) architectural interventions mitigate the spread of emerging respiratory pathogens using the example of SARS-CoV-2 in a prototypical ED.

Methods

Using an agent-based approach, we integrated data on patients' and healthcare workers' (HCWs) routines and the architectural characteristics of key ED areas. We estimated the number of transmissions in the ED by modelling the interactions between and among patients and HCWs. Architectural interventions were guided towards the gradual separation of pathogen carriers, compliance with a minimum interpersonal distance, and deconcentrating airborne pathogens (higher air exchange rates (AERs)). Interventions were epidemiologically evaluated for their mitigation effects on diverse endpoints.

Results

Simulation results indicated that higher AERs in the ED (compared with baseline) may provide a moderate level of infection mitigation (incidence rate ratio (IRR) of 0.95 (95% confidence interval (CI) 0.93–0.98)) while the overall burden decreased more when rooms in examination areas were separated (IRR of 0.78 (95% CI 0.76–0.81)) or when the size of the ED base was increased (IRR of 0.79 (95% CI 0.78–0.81)). The reduction in SARS-CoV-2-associated nosocomial transmissions was largest when architectural interventions were combined (IRR of 0.61 (95% CI 0.59–0.63)).

Conclusions

These modelling results highlight the importance of IPC architectural interventions; they can be devised independently of profound knowledge of an emerging pathogen, focusing on technical, constructive, and functional components. These results may inform public health decision-makers and hospital architects on how IPC architectural interventions can be optimally used in healthcare premises.

Le texte complet de cet article est disponible en PDF.

Keywords : Architectural interventions, Infection prevention and control, Nosocomial infections, SARS-CoV-2, Agent-based modelling


Plan


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 151

P. 1-10 - septembre 2024 Retour au numéro
Article précédent Article précédent
  • Practices to prevent non-ventilator hospital-acquired pneumonia: a narrative review
  • A. Livesey, S. Quarton, H. Pittaway, A. Adiga, F. Grudzinska, D. Dosanjh, D. Parekh
| Article suivant Article suivant
  • Protracted transmission and persistence of ST80 vancomycin-resistant Enterococcus faecium clonal complex types CT2933, CT2932 and CT1916 in a large Irish hospital: a 39-month whole-genome sequencing study
  • N.L. Kavanagh, P.M. Kinnevey, S.A. Egan, B.A. McManus, B. O'Connell, G.I. Brennan, D.C. Coleman

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.