Frequency of Agreement Between Structural and Functional Glaucoma Testing: A Longitudinal Study of 3D OCT and Current Clinical Tests - 13/09/24

Doi : 10.1016/j.ajo.2024.05.018 
Dhruv Manik a, b, c, Kitiya Ratanawongphaibul b, c, d, Janice Kim b, c, Edem Tsikata b, c, Hang Lee c, e, Milica A. Margeta b, c, Courtney L. Ondeck b, c, f, Johannes F. De Boer g, h, Teresa C. Chen b, c,
a From the Boston University Chobanian & Avedisian School of Medicine (D.M.), Boston, Massachusetts, USA 
b Department of Ophthalmology, Glaucoma Service, Massachusetts Eye and Ear (D.M., K.R., J.K., E.T., M.A.M., C.L.O., T.C.C.), Boston, Massachusetts, USA 
c Harvard Medical School (D.M., K.R., J.K., E.T., H.L., M.A.M., C.L.O., T.C.C.), Boston, Massachusetts, USA 
d Center of Excellence in Glaucoma, Faculty of Medicine, Chulalongkorn University and King Chulalongkorn Memorial Hospital, Thai Red Cross Society (K.R.), Bangkok, Thailand 
e Massachusetts General Hospital Biostatistics Center, Department of Medicine, Massachusetts General Hospital (H.L.), Boston, Massachusetts, USA 
f Department of Ophthalmology, VA Boston Hospital (C.L.O.), Boston, Massachusetts, USA 
g LaserLaB Amsterdam, Department of Physics and Astronomy, Vrijie Universiteit (J.F.D.B.), Amsterdam, The Netherlands 
h Department of Ophthalmology, Vrijie Universiteit Medical Center (J.F.D.B.), Amsterdam, The Netherlands 

Inquiries to Teresa C. Chen, Massachusetts Eye and Ear, Department of Ophthalmology, Glaucoma Service, 243 Charles Street, Boston, MA, 02114, USAMassachusetts Eye and EarDepartment of OphthalmologyGlaucoma Service243 Charles StreetBostonMA02114USA

Highlights

Structural and functional tests of glaucoma often progress at different times.
Most of the time, glaucoma progression is only detected by one or two tests.
Physicians should use multiple testing methods to assess glaucoma progression.
Physicians may need to escalate treatment even if only one test progresses.

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

To evaluate how often tests of structure and function detect glaucoma progression at the same study visit. Tests include current glaucoma clinical tests and a new 3-dimensional (3D) optical coherence tomography (OCT) rim measurement.

Design

Prospective cohort study.

Methods

For 124 open-angle glaucoma patients at a single institution, one eye was randomly selected for each patient. Patients were included if they had open-angle glaucoma and if they had at least 4 yearly study visits. Study visits included a full dilated eye exam, disc photography (DP), Humphrey visual field (HVF 24–2) testing, 2D OCT retinal nerve fibre layer (RNFL) thickness measurements, and 3D OCT neuroretinal rim measurements (i.e., minimum distance band or MDB). For each test at each study visit, eyes were classified as progressors or non-progressors using event-based analysis. Agreement occurred if tests progressed in the same eye at the same study visit. Agreements between all compared tests were calculated as percentages of agreement.

Results

The study included 124 open-angle glaucoma eyes, which had an average follow-up period of 66.9 ± 16.4 months. Structural tests (i.e., DP, global RNFL thickness, and global MDB rim thickness) progressed at the same visit as the functional test (i.e., HVF testing) in only 5.0% (3/60) to 16.0% (13/81) of eyes. Global MDB thickness and global RNFL thickness showed similar agreement with functional HVF testing (i.e., 16.0% [13/81] and 8.3% [7/84], respectively), and global MDB thickness showed better structure-function agreement with HVF testing than between DP and HVF testing (i.e., 5.0% [3/60], P = 0.04). For all paired comparisons between testing methods, eyes with moderate glaucoma showed similar or better agreement than eyes with mild or severe glaucoma.

Conclusions

Clinical tests of structure and function do not usually progress at the same clinic visit. Most of the time, glaucoma progression is only detected by one or two tests.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.
 Meeting Presentations: World Ophthalmology Congress 2022, International Council of Ophthalmology.


© 2024  The Authors. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 266

P. 196-205 - octobre 2024 Retour au numéro
Article précédent Article précédent
  • Risk Factors for Retinal Detachment in Marfan Syndrome After Pediatric Lens Removal
  • Youssef Abdelmassih, Régis Lecoge, Mehdi El Hassani, Pascal Dureau, Georges Caputo, Florence Metge, Thibaut Chapron
| Article suivant Article suivant
  • Pan-viral Antibody Repertoire of Aqueous Humor in Cytomegalovirus Uveitis
  • Charles Kevin Tiu, Wan Ni Chia, Danielle E. Anderson, Soon-Phaik Chee, Lin-Fa Wang, Jay Siak

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.