Retinal thickness and macular microvascular changes seen on optical coherence tomography angiography (OCTA) in patients with sickle cell retinopathy in a tertiary care eye hospital - 24/09/24

Doi : 10.1016/j.jfop.2024.100138 
Olufemi Oderinlo , Oyekunle Idris, Lateefat Oshunkoya, Adekunle Hassan, Abiodun Olukotun
 Eye Foundation Hospital, 27 Isaac John Street, GRA Ikeja, Lagos, Nigeria 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Purpose

To report retinal thickness values and macular vascular flow characteristics identified by optical coherence tomography angiography (OCT-A) in patients with various sickle cell genotypes in a population from sub-Saharan Africa.

Design

Retrospective, observational study.

Methods

This is a single-institution case series of adult patients with various sickle cell genotypes who presented to the Eye Foundation Hospital Lagos between January 2022 and December 2023. Case files of patients were reviewed, and macular OCT and OCT-A images analyzed quantitatively for macular thickness, areas of flow loss, size of foveal avascular area, parafoveal flow, as well as vascular density in both the superficial and deep vascular plexi. The findings were compared by sickle cell genotype and comparisons made with age matched normal patients.

Results

A total of 38 eyes of 19 patients’ records were reviewed, and 35 eyes met the inclusion criteria; 16 eyes of 9 age and gender matched controls were included. The mean central foveal thickness (CFT) was 242.4 μm ± 33.3 μm among patients’ eyes, while a mean CFT of 236.1 μm ± 10.1 μm was measured among controls (p = 0.312). A smaller mean FAZ area of 0.270 mm2 ± 0.116 mm2 was seen among the control eyes compared to a mean of 0.314 mm2 ± 0.206 mm2 among patients’ eyes (p = 0.439). The mean flow area was larger among control eyes with 0.849 mm2 ± 0.647 mm2 compared to a mean flow of 0.822 mm2 ± 0.471 mm2 among patients’ eyes (0.868). The mean superficial foveal vessel density was greater among control eyes (19.30 ± 4.58) compared to patient eyes (18.77 ± 7.78) (p = 0.765). The mean deep foveal vessel density was greater among controls (35.30 ± 8.36) than among patients (34.06 ± 9.30) (p = 0.650). The difference between eyes of SC (53.37 ± 5.13) patients and SS (47.94 ± 8.44) patients in the deep temporal perifoveal VD was statistically significant (p = 0.035).

Conclusion

The retina in eyes with sickle retinopathy and that of controls tends to be thickest in the nasal quadrant, then the superior, then inferior, and then thinnest in the temporal quadrant. Macular vessel density in both the superficial and deep capillary plexi was thicker among controls compared to eyes with sickle cell retinopathy. Among patients’ eyes, the deep capillary vessel density in the temporal perifoveal quadrant was greater among SC patients compared to SS (p = 0.035).

Le texte complet de cet article est disponible en PDF.

Keywords : Sickle cell retinopathy, Sickle cell maculopathy, Macular vessel density, Foveal avascular zone, Macular blood flow


Plan


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 8

Article 100138- décembre 2024 Retour au numéro
Article précédent Article précédent
  • Assessing the awareness and knowledge of the adverse ocular side effects associated with oral contraceptives among women between the ages of 16 and 40 in Benin-city, Edo state, Nigeria
  • Obehi Suzan Idogen
| Article suivant Article suivant
  • Optical coherence tomography (OCT) and OCT Angiography in Stages 3 and 4 proliferative sickle cell retinopathy
  • Ogugua Ndubuisi Okonkwo, Adekunle Olubola Hassan, Oyekunle Idris, Arinze Anthony Onwuegbuna, Toyin Akanbi, Chineze Agweye, Utam Ashibel

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.