S'abonner

Optical Coherence Tomography Advanced Parameters in Patients With Multiple Sclerosis: Ophthalmological and Neurological Assessments - 14/10/24

Doi : 10.1016/j.ajo.2024.06.011 
MARIA CRISTINA SAVASTANO 1, 2, #, VIVIANA NOCITI 2, 3, #, FEDERICO GIANNUZZI 1, 2, , VALENTINA CESTRONE 1, 2, MATTEO MARIO CARLÀ 1, 2, CLAUDIA FOSSATARO 1, 2, ILARIA BIAGINI 2, 5, CLARA RIZZO 6, 7, RAPHAEL KILIAN 7, MARCO BISURGI 3, 4, PAOLO CALABRESI 4, MASSIMILIANO MIRABELLA 3, 4, , STANISLAO RIZZO 1, 2, 8,
1 From the Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS (M.C.S., F.G., V.C., M.M.C., C.F., S.R.), Rome, Italy 
2 Catholic University of the Sacred Heart (M.C.S., V.N., F.G., V.C., M.M.C., C.F., I.B., S.R.), Rome, Italy 
3 Centro di Ricerca Sclerosi Multipla (CERSM), Università Cattolica (V.N., M.B., M.M.), Rome, Italy 
4 UOC Neurologia, Dipartimento di Neuroscienze, Organi di Senso e Torace, Fondazione Policlinico Universitario Agostino Gemelli IRCCS (M.B., P.C., M.M.), Rome, Italy 
5 Department NEUROFARBA, University of Florence (I.B.), Florence, Italy 
6 Ophthalmology, Department of Surgical, Medical and Molecular Pathology and Critical Care Medicine, University of Pisa (C.R.), Pisa, Italy 
7 Ophthalmology Unit, University of Verona (C.R., R.K.), Verona, Italy 
8 Consiglio Nazionale delle Ricerche, Istituto di Neuroscienze (S.R.), Pisa, Italy 

Inquiries to Federico Giannuzzi, MD, FEBO, Ophthalmology Unit, Fondazione Policlinico Universitario A. Gemelli, IRCCS, Catholic University Sacro Cuore, Largo A. Gemelli, 8, Rome, ItalyOphthalmology UnitFondazione Policlinico Universitario A. GemelliIRCCS, Catholic University Sacro CuoreLargo A. Gemelli, 8RomeItaly

Résumé

Purpose

To evaluate ophthalmological, neurological, radiological, and laboratory data in patients with multiple sclerosis (MS) and to identify new ophthalmological factors that could be helpful as biomarkers of the disease, potentially leading to an earlier prediction of disease course and disability progression.

Design

Retrospective, cross-sectional-study.

Methods

Best-corrected visual acuity (BCVA), ophthalmological biomicroscopy of the anterior segment and fundus, structural optical coherence tomography (OCT) with retinal nerve fiber layer (RNFL) and ganglion cell complex (GCC), and OCT angiography (OCTA) with vascular density (VD) were performed. The following clinical and neuro-radiological features were assessed: MS phenotype, disease duration, clinical severity, type of treatment, and T2-weighted lesion and T1-weighted Gd+ enhancing lesion number on the brain and spinal cord MRI.

Results

One hundred and six patients (212 eyes) were analyzed. Sixty-six of them (62.2%) had MS and 40 (37.8%) were matched healthy controls (HCs). patients with MS showed lower RNFL, GCC, and VD in the radial peripapillary capillary plexus than controls in both eyes (P < .05). By Performing a logistic regression with a distinct MS outcome for both eyes, we were able to demonstrate that the value that was most predictive of MS was the average GCC thickness (P = .009). Regression analysis demonstrated that patients with a higher T2-weighted lesions showed a lower RNFL thickness value and reduced GCC and VD values than those with a low lesion load (P < .01 and P < .05, respectively). Similarly, relapsing MS patients showed lower RNFL values (P < .05).

Conclusions

Several OCT and OCTA-optic nerve parameters could be useful prognostic biomarkers for the MS disease course in clinical practice. However, it is necessary to do additional research with larger sample sizes in order to validate these findings.

Le texte complet de cet article est disponible en PDF.

Plan


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 267

P. 41-49 - novembre 2024 Retour au numéro
Article précédent Article précédent
  • Anesthesia Techniques for Vitreoretinal Surgery in the United States: A Report from the Multicenter Perioperative Outcomes Group Research Consortium
  • MUHAMMAD Z. CHAUHAN, MOHAMED K. SOLIMAN, NATHAN L. PACE, MICHAEL R. MATHIS, ROBERT B. SCHONBERGER, AHMED B. SALLAM, MPOG Investigator Group
| Article suivant Article suivant
  • Improvement of the Ocular Prognosis of Stevens-Johnson Syndrome and Toxic Epidermal Necrolysis: A National Survey in Japan
  • Miho Kojima, Hiroki Mieno, Mayumi Ueta, Mitsuko Nakata, Satoshi Teramukai, Yuma Sunaga, Hirotaka Ochiai, Masafumi Iijima, Akatsuki Kokaze, Hideaki Watanabe, Michiko Kurosawa, Hiroaki Azukizawa, Hideo Asada, Yuko Watanabe, Yukie Yamaguchi, Michiko Aihara, Zenro Ikezawa, Yoshiko Mizukawa, Manabu Ohyama, Tetsuo Shiohara, Natsumi Hama, Riichiro Abe, Hideo Hashizume, Saeko Nakajima, Takashi Nomura, Kenji Kabashima, Mikiko Tohyama, Koji Hashimoto, Hayato Takahashi, Hiroyuki Niihara, Eishin Morita, Hirohiko Sueki, Shigeru Kinoshita, Chie Sotozono

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.