Doi : 10.1016/j.otsr.2024.103981 
Roger Erivan a, , Antoine Urbain b, Tony Santorum c, Gérard Giordano d, Nicolas Reina e, François Bonnomet f, Jean Yves Jenny g, Henri Peuchot h, Nicolas Bonin i, Mehdi Hormi-Menard b, Bruno Miletic j, Julien Wegrzyn k, Fredson Razanabola l, Christophe Jardin m, Hervé Nieto n, François Loubignac o, Jean Matsoukis p, Jérémy Hardy q, Alain Duhamel b, Henri Migaud b,  SoFCOT r
a Université Clermont Auvergne, CHU Clermont-Ferrand, CNRS, SIGMA Clermont, ICCF, F-63000 Clermont–Ferrand, France 
b Université de Lille, Hôpital Salengro, CHU de Lille, Place de Verdun, 59037 Lille, France 
c Centre de Simulation PRESAGE, Université de Lille, Place de Verdun, 59037 Lille, France 
d Hôpital Joseph Ducuing, 15 Rue Varsovie, 31300 Toulouse, France 
e Hôpital Pierre Paul Riquet, CHU Toulouse, Place du Dr Baylac, 31300 Toulouse, France 
f Hôpital de Hautepierre, CHU Strasbourg, 1 Av. Molière, 67200 Strasbourg, France 
g Impulse Ortho, Clinique Sainte-Odile, 3 Rue de la Redoute, 67500 Haguenau, France 
h Hôpital d'Aix-en-Provence, Service Chirurgie, Avenue des Tamaris, 13100 Aix-en-Provence, Institute for Locomotion, Department of Orthopedic Surgery, Aix-Marseille University, Sainte-Marguerite Hospital, 270, Boulevard Sainte-Marguerite, 13009 Marseille, France 
i Lyon Ortho Clinic, 29 Av. des Sources, 69009 Lyon, France 
j Clinique de La Louvière, 69 rue de la Louvière, 59000 Lille, France 
k Department of Orthopedic Surgery, Lausanne University Hospital and University of Lausanne, 46 Rue du Bugnon, Lausanne, Switzerland 
l CHU Orléans, 14 Avenue de l'Hôpital, 45100 Orléans, France 
m Clinique des Ormeaux, 36 rue Marceau 76600 Le Havre, France 
n Centre Hospitalier de Niort 40 Avenue Charles de Gaulle 79021 Niort, France 
o CH Toulon 54 Rue Henri Sainte-Claire Deville, 83100 Toulon, France 
p CH du Havre, 29 Avenue Pierre Mendès France 76290 Montivilliers, France 
q CHU Dupuytren Limoges, 2 Av. Martin Luther King, 87000 Limoges, France 
r Société Française de Chirurgie Orthopédique et de Traumatologie (SoFCOT), 56 rue Boisssonade 75014 Paris, France 

Corresponding author.

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Introduction

The threshold of a Leg Length Discrepancy (LLD) by clinical examination on a sheet or centimeter paper (CP) is not known precisely whether or not it concerns limbs equipped with a hip prosthesis. We therefore conducted a prospective in silico study in order to: (1) determine the reproducibility and sensitivity of the clinical measurement of the LLD in different ideal and "degraded" clinical situations, (2) determine the threshold from which the human eye is capable of detecting a length inequality in clinic, (3) to determine whether the use of a graduated support (centimeter paper) improves the clinical measurement threshold.

Hypothesis

Our hypothesis was that clinical measurement on a centimeter support would improve clinical measurement accuracy.

Material and methods

This was an in silico study, the experiment was conducted on a mannequin. Different inequalities were created on a mannequin and photographed with a total of 30 inequalities from −22 to +22 mm on sheet or centimeter paper (CP). This was a multicenter study, with 40 different readers. We asked the readers to make a second measurement one month later. We evaluated the inter- and intra-observer reproducibility. The error rate at the threshold of 3 mm and 5 mm were calculated versus the gold standard. Finally, we determined at which thresholds respectively 75% and 95% of the measurements were correct.

Results

A total of 4140 measurements were performed and compared to the gold standard. With a threshold of 75% accurate measurement, the LLD detection threshold was 2.8 mm on centimeter paper and 4.5 mm on sheet. With a threshold of 95% accurate measurement, the LLD detection threshold was 3.4 mm on centimeter paper and 5.2 mm on sheet. Interobserver agreement (assessed overall on the 40 observers by Krippendorff's generalized Kappa) was 0.86 (95% confidence interval (CI95%) = 0.79 to 0.92) on CP and 0.71 (CI95% = 0.63 to 0.79) on sheet. Intra-observer agreement assessed by the intraclass correlation coefficient among observers who made 2 measurements had a median value (IQR) of 0.96 (0.94 to 0.99) on CP and 0.90 (0.83 to 0.94) on sheet.

Discussion

The clinical detection threshold on sheet at the patient's bed appears close to 5 mm. A more precise measurement is possible with graduated centimeter paper. A study in daily practice on patients in real situations would confirm our results.

Level of evidence

III; prospective diagnostic comparative in Silico study.

Le texte complet de cet article est disponible en PDF.

Keywords : Lower limb length inequality, In silico study, Clinical measurement


Plan


© 2024  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 110 - N° 8

Article 103981- décembre 2024 Retour au numéro
Article précédent Article précédent
  • Conversion of hip resurfacing to total hip arthroplasty: is the outcome closer to primary or revision total hip arthroplasty?
  • Marion Mutschler, Allegra Massazza, Alexander Antoniadis, Michele Palazzuolo, Julien Wegrzyn
| Article suivant Article suivant
  • Do the porous custom implants have a position consistent with the planning and allow anatomical reconstruction of hip center of rotation in complex acetabular revisions Paprosky III?
  • Constant Foissey, Sophie Putman, Adrien Zampieri, Henri Migaud, Julien Dartus

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.