S'abonner

Three-Dimensional Quantitative Analysis of Internal Limiting Membrane Peeling Related Structural Changes in Retinal Detachment Repair - 09/12/24

Doi : 10.1016/j.ajo.2024.08.022 
Tzu-Han Hsieh 1, Jia-Kang Wang 1, 2, 4, Fang-Ting Chen 1, 2, 3, Yun-Ju Chen 1, 2, 3, Ling-Uei Wang 1, Tzu-Lun Huang 1, 4, Pei-Yao Chang 1, 2, 3, Yung-Ray Hsu 1, 2, 3, 4,
1 From the Department of Ophthalmology (T-H.H., J-K.W., F-T.C., Y-J.C., L-U.W., T-L.H., P-Y.C., Y-R.H.), Far Eastern Memorial Hospital, New Taipei City, Taiwan 
2 Department of Ophthalmology (J-K.W., F-T.C., Y-J.C., P-Y.C., Y-R.H.), National Taiwan University Hospital, Taipei, Taiwan 
3 National Taiwan University College of Medicine (F-T.C., Y-J.C., P-Y.C., Y-R.H.), Taipei, Taiwan 
4 Department of Electrical Engineering (J-K.W., T-L.H., Y-R.H.), Yuan Ze University, Taoyuan, Taiwan 

Inquiries to: Yung-Ray Hsu, Department of Ophthalmology, Far Eastern Memorial Hospital, New Taipei City, TaiwanDepartment of OphthalmologyFar Eastern Memorial HospitalNew Taipei CityTaiwan

Résumé

Purpose

To assess macular microstructural changes associated with internal limiting membrane peeling (ILMP) using 3-dimensional optical coherence tomography (3D-OCT) in primary macula-off rhegmatogenous retinal detachment (RRD) repairs with vitrectomy and silicone oil (SO) tamponade.

Design

Retrospective, consecutive, interventional case series.

Methods

Setting: Institutional practice. Patient Population: Patients who received primary RRD repair by a single experienced surgeon between January 2017 and December 2021. Main Outcome Measures: In the qualitative comparative analysis, the presence of macular changes among patients who underwent primary RRD repair with (21 eyes) or without ILMP (20 eyes) were observed. Subsequently, a detailed quantitative analysis of ILMP-related microstructural changes in 56 eyes using both 3D and 2D-OCT images were performed.

Results

In the qualitative comparative analysis, macular microstructural changes were observed in 95% of ILMP eyes and 5% of non-ILMP eyes (p < .001). In the quantitative analysis, 4 major macular microstructural changes were detected: dimple (75%), dissociated nerve fiber layer (DONFL) (55%), ILM peeling edge thinning (IPET) (64%), and temporal macular groove (TMG) (23%). Dimples (n = 251, average 4.5 ± 5.8 per eye) could be further classified into type I (confined to the inner plexiform layer [IPL]; 73%) and type II (beyond IPL, 27%). The average depth of the deepest dimples was 58 ± 18 µm. The extent of IPET was 6.0 ± 3.7 clock hours. The average length of TMG was 1.8 ± 0.4 mm. Comparing to unoperated fellow eyes, the eyes after ILMP showed decreased inner temporal over nasal retinal thickness ratio (0.86 ± 0.07 versus 0.96 ± 0.03, p < .001), shorter disc-fovea distance (4.61 ± 0.32 µm versus 4.78 ± 0.37 µm, p = .041), and wider retinal vein trajectories (c’ = 2.48 ± 0.84 vs 3.39 ± 1.61, p = .002).

Conclusions

Macular microstructural changes are common after ILMP in RRD repair, encompassing both focal changes (dimples, DONFL) and zonal changes (IPET, TMG). DONFL and dimples may be part of a continuum of findings stemming from the same mechanism. IPET and TMG are the results of macular tissue shift due to contracture of the optic disc and neurovascular bundle.

Le texte complet de cet article est disponible en PDF.

Plan


 Supplemental Material available at AJO.com.


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 269

P. 94-104 - janvier 2025 Retour au numéro
Article précédent Article précédent
  • Sociodemographic Factors Associated With Emergent Eye-Related Emergency Department Visits: A Multicenter Analysis
  • Michael Quintero, Heba Mahjoub, Joseph Ssekasanvu, Yoshihiro Yonekawa, Grant A. Justin, Kara M. Cavuoto, Alice Lorch, Vrinda Madan, Ishu Sivakumar, Xiyu Zhao, Olivia Febles Simeon, Mirataollah Salabati, Connie M. Wu, Fasika A. Woreta
| Article suivant Article suivant
  • Incidence and Progression of Diabetic Retinopathy After Cataract Surgery: A Systematic Review and Meta-Analysis
  • SSU-HSIEN LEE, BOR-YUAN TSENG, MENG-CHIEN WU, JEN-HUNG WANG, CHENG-JEN CHIU

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.