S'abonner

Cornea Endothelial Cell Loss Before and After Explantation of Artisan and Artiflex Iris-Fixated Phakic Intraocular Lenses - 13/01/25

Doi : 10.1016/j.ajo.2024.10.010 
Hye yeon Yoon, MD. 2 , Yong-Soo Byun, MD., PhD. 1, Hyun Seung Kim, MD., PhD. 1, So-Hyang Chung, MD., PhD. 1,
1 From the Department of Ophthalmology and Visual Science (Y.S.B., H.S.K., S.H.C.), Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea 
2 Department of Ophthalmology and Visual Science (H.Y.Y.), Yeouido St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea 

Inquiries to So-Hyang Chung, Department of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Seocho-gu, Republic of KoreaDepartment of Ophthalmology and Visual ScienceSeoul St. Mary's Hospital, College of Medicine, The Catholic University of KoreaSeoulSeocho-guRepublic of Korea

Résumé

PURPOSE

To investigate the risk factors for corneal endothelial cell density (ECD) loss of 2 types of iris-fixated phakic intraocular lenses (pIOL) and indicate the cutoff values for preventing irreversible ECD loss after explantation.

DESIGN

The retrospective, comparative, clinical cohort study.

METHODS

Total 114 eyes of 61 patients were included in this study. Fifty-five eyes with Artisan pIOL and 59 eyes with Artiflex pIOL had undergone explantation of pIOLs due to continuous ECD loss. Correlation analysis was performed to assess the ocular parameters associated with ECD loss. Receiver operating characteristic (ROC) curve was performed to set cutoff values of ocular parameters to prevent ECD loss after explantation.

RESULTS

The mean ECD before explantation was 1637 cells/mm2 in Artisan group and 1769 cells/mm2 in Artiflex group. The distance of cornea endothelium to IOL center and edges were all significantly higher in Artisan group (P < .05). The risk factor of decreased ECD in Artisan group were small anterior chamber angle (ACA), and distance of nasal edge of IOL to endothelium and iris fixation to nasal limbus distance, and differences of fixation length. In Artiflex group, ACA, distance of nasal edge of IOL to endothelium, both limbus to IOL fixation length, fixation length, iris pigmentation grading were the risk factors. At 1 year after the pIOL removal, the population demonstrating ΔECD >10% were significantly higher in Artisan group than Artiflex group (P < .05). In ROC curve analysis, the cutoff value of preoperative ECD to prevent significant postexplantation ECD loss was 1683.5 cells/mm2 in Artisan group and 1648 cells/mm2 in Artiflex group.

CONCLUSIONS

This study examined the existing explantation guidelines for these lenses. In analyzing the longterm prognosis of cornea ECD with Iris-fixated phakic intraocular lens, it is important to identify the relevant anatomical factors. Small ACA, and short distances from IOL to endothelium and from limbus to iris fixation especially in the nasal region were significant risk factors to continuous ECD loss in both lenses. To minimize irreversible ECD loss after explantation, it is important to determine the optimal period of explantation by observing both ECD and structural changes.

Le texte complet de cet article est disponible en PDF.

Plan


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 270

P. 52-60 - février 2025 Retour au numéro
Article précédent Article précédent
  • Multimodal Imaging Characteristics and Correlation to Outcomes in Patients With Central Retinal Artery Occlusion Presenting to a Large Academic Center
  • Sandra Hoyek, Melissa Yuan, Romy Bejjani, David N. Zacks, Joan W. Miller, Demetrios G. Vavvas, Nimesh A. Patel
| Article suivant Article suivant
  • Associations Between Dry Eye Disease and Mental Health Conditions in the All of Us Research Program
  • AARON T. ZHAO, JOCELYN HE, YUQING LEI, YONG CHEN, GUI-SHUANG YING

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.