S'abonner

Refining computer-assisted SEEG planning with spatial priors – A novel comparison of implantation strategies across adult and paediatric centres - 14/01/25

Doi : 10.1016/j.neucli.2024.103038 
Debayan Dasgupta a, b, , Aswin Chari a, c, Mehdi Khan d, e, Friederike Moeller f, Zubair Tahir e, Andrew W McEvoy a, Anna Miserocchi a, John S Duncan b, Rachel E. Sparks g, Martin Tisdall c, e
a Victor Horsley Department of Neurosurgery, National Hospital for Neurology and Neurosurgery, Queen Square, London, WC1N 3BG, UK 
b Department of Clinical and Experimental Epilepsy, UCL Queen Square Institute of Neurology, University College London, London, WC1N 3BG, UK 
c Developmental Neurosciences, UCL Great Ormond Street Institute of Child Health, London, WC1N 1EH, UK 
d University College London Medical School, London, WC1E 6BT, UK 
e Department of Neurosurgery, Great Ormond Street Hospital for Children, London, WC1N 3JH, UK 
f Department of Neurophysiology, Great Ormond Street Hospital for Children, London, WC1N 3JH, UK 
g School of Biomedical Engineering & Imaging Sciences, King's College London, London, WC2R 2LS, UK 

Corresponding author.

Abstract

Objectives

Computer-assisted planning (CAP) allows faster SEEG planning and improves grey matter sampling, orthogonal drilling angles to the skull, reduces risk scores and minimises intracerebral electrode length. Incorporating prior SEEG trajectories enhances CAP planning, refining output with centre-specific practices. This study significantly expands on the previous work, compares priors libraries between two centres, and describes differences between SEEG in adults and children in these centres.

Methods

98 adults and 61 children who underwent SEEG implantation as part of epilepsy surgery investigations were included. Priors libraries were created for each population, clustered by target regions and subdivided by cortical approaches. The libraries were coregistered and quantitatively and qualitatively compared.

Results

The average number of implanted electrodes per patient was higher in paediatric patients than adults (13.6 vs 8.0). Paediatric implantations focused more on the insula than adult implantations (38.0 % vs 13.5 %), with similar proportions of electrodes implanted in the temporal and parietal lobes, and a higher proportion of adult electrodes in the frontal and orbitofrontal regions (40.6 % vs 24.0 %). Correspondence between the priors libraries was high. We present an example of a complex insular implantation planned with paediatric spatial priors and illustrate resultant SEEG recordings.

Discussion

The use of centre-specific spatial priors allows the incorporation of surgeon-specific and unit-specific preferences into automated planning. We compare implantation styles between a paediatric and an adult centre, discussing similarities and differences. This tool allows centres to compare practice and represents an effective way to analyse implantation strategies that is agnostic to method of implantation.

Le texte complet de cet article est disponible en PDF.

Keywords : Stereoelectroencephalography (SEEG), Computer-assisted planning, Spatial priors, Epilepsy surgery, Intracranial EEG, Surgical planning


Plan


© 2024  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 55 - N° 1

Article 103038- janvier 2025 Retour au numéro
Article précédent Article précédent
  • The development of Stereo-Electroencephalography (SEEG) in Southeast Asia and Oceania: Challenges to equity across the region.
  • Michael W.K. Fong, Kheng-Seang Lim, Si Lei Fong, Chien Chen, Shang-Yeong Kwan, Cheng-Chia Lee, Piradee Suwanpakdee, Charcrin Nagangchang, Minh-An Thuy Le, Yee-Mon Khine, Deepak Gill, Chong H. Wong
| Article suivant Article suivant
  • SEEG seizure onset patterns in mesial temporal lobe epilepsy: A cohort study with 76 patients
  • Du Cai, Xiu Wang, Wenhan Hu, Jiajie Mo, Baotian Zhao, Zhong Zheng, Lin Sang, Xiaoqiu Shao, Chao Zhang, Jianguo Zhang, Kai Zhang

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.