Accuracy of 7 Artificial Intelligence–Based Intraocular Lens Power Calculation Formulas in Extremely Long Caucasian Eyes - 13/02/25

Doi : 10.1016/j.ajo.2024.10.033 
Wiktor Stopyra 1, 2 , Oleksiy Voytsekhivskyy 3, Andrzej Grzybowski 4, 5,
1 From the MW-Med Eye Centre (W.S.), Krakow, Poland 
2 Department of Medicine (W.S.), University of Applied Sciences, Nowy Targ, Poland 
3 Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center (O.V.), Kyiv, Ukraine 
4 Institute for Research in Ophthalmology (A.G.), Foundation for Ophthalmology Development, Poznan, Poland 
5 Department of Ophthalmology (A.G.), University of Warmia and Mazury, Olsztyn, Poland 

Inquiries to Andrzej Grzybowski, Institute for Research in Ophthalmology, Foundation for Ophthalmology Development, Poznan, PolandInstitute for Research in OphthalmologyFoundation for Ophthalmology DevelopmentPoznanPoland

Résumé

Purpose

To compare 7 artificial intelligence (AI)–based intraocular lens (IOL) power calculation formulas in extremely long eyes.

Design

Retrospective accuracy and validity analysis.

Setting

Kyiv Clinical Ophthalmology Hospital Eye Microsurgery Center, Ukraine.

Study Population

Patients with highly myopic eyes, who underwent uneventful phacoemulsification.

Observation Procedures

IOL power was calculated before cataract surgery. The power of the implanted IOL was randomly selected from the outcomes of SRK/T, Holladay 2, or Barrett Universal II. Three months after phacoemulsification, refraction was measured. Postsurgery IOL power calculations were performed using the following formulas: Hill-RBF 3.0, Kane, PEARL-DGS, Ladas Super Formula AI (LSF AI), Hoffer QST, Karmona, and Zhu-Lu.

Main Outcome Measures

Root mean square absolute error (RMSAE), median absolute error (MedAE), and percentage of eyes with prediction error within ±0.50 D.

Results

Forty-eight eyes with axial length > 30.00 mm were studied. Hill-RBF 3.0 yielded the lowest RMSAE (0.788) with statistical superiority only over Karmona (0.956, P = .021). In terms of MedAE, outcomes obtained by Hoffer QST (0.442) and Hill-RBF (0.490) were statistically significant compared with LSF AI (0.800, P = .013 and P = .008, respectively). The highest percentage of eyes with prediction error within ±0.50 D was achieved by Hill-RBF 3.0, Kane, and Hoffer QST (54.17% each) statistically significant as follows: both Hill-RBF and Kane compared with LSF AI (27.08%) and Karmona (39.58%), and Hoffer QST compared with LSF AI.

Conclusion

All tested formulas demonstrated comparable trueness, with Hill-RBF 3.0 being more accurate than Karmona (RMSAE), and LSF AI being less accurate than Hoffer QST and Hill-RBF 3.0 (MedAE).

Le texte complet de cet article est disponible en PDF.

Plan


  Supplemental Material available at AJO.com .


© 2024  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 271

P. 337-346 - mars 2025 Retour au numéro
Article précédent Article précédent
  • Combining Paracentral Acute Middle Maculopathy and Peripapillary Fluid as Biomarkers in Anterior Ischemic Optic Neuropathy
  • Oliver Niels Klefter, Michael Stormly Hansen, Lea Lykkebirk, Yousif Subhi, Jane Maestri Brittain, Mads Radmer Jensen, Uffe Møller Døhn, Viktoria Fana, Anne Katrine Wiencke, Steffen Heegaard, Lene Terslev, Steffen Hamann
| Article suivant Article suivant
  • Repeatability of Microperimetry in Areas of Retinal Pigment Epithelium and Photoreceptor Loss in Geographic Atrophy Supported by Artificial Intelligence–Based Optical Coherence Tomography Biomarker Quantification
  • Leonard M. Coulibaly, Klaudia Birner, Azin Zarghami, Markus Gumpinger, Simon Schürer-Waldheim, Philipp Fuchs, Hrvoje Bogunović, Ursula Schmidt-Erfurth, Gregor S. Reiter

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.