Comparative Evaluation of the Corneal Sensitivity Thresholds between the Novel Non-Contact and Cochet-Bonnet Esthesiometers - 13/02/25

Doi : 10.1016/j.ajo.2024.12.013 
RAUL E. RUIZ-LOZANO 1, 2, MANUEL E. QUIROGA-GARZA 1, EUGENIA M. RAMOS-DÁVILA 2, JEZREEL PANTALEÓN-GARCÍA 3, ALI KHODOR 1, SEITARO KOMAI 1, LUIS A. RODRIGUEZ-GUTIERREZ 1, SYMON MA 1, HAZEM M. MOUSA 4, ROBBY MATTES 1, SANDRA S. STINNETT 5, ALFONSO L. SABATER 1, VICTOR L. PEREZ 1,
1 From the Bascom Palmer Eye Institute, University of Miami, Miami, Florida, USA 
2 Tecnologico de Monterrey, School of Medicine and Health Sciences, Institute of Ophthalmology and Visual Sciences, Monterrey, Mexico 
3 Department of Pulmonary Medicine, University of Texas MD Anderson Cancer Center, Houston, Texas, USA 
4 Department of Ophthalmology, Foster Center for Ocular Immunology at Duke Eye Center, Duke University School of Medicine, Durham, North Carolina, USA 
5 Associate Professor of Biostatistics and Bioinformatics, Duke University School of Medicine, Durham, North Carolina, USA 

Inquiries to Victor L. Perez, Professor of Ophthalmology, Director of Cornea Research Program, Bascom Palmer Eye Institute, University of Miami Miller School of Medicine, McKnight Vision Research Center, 900 NW 17th St, Miami, Florida, 33136, USA Professor of Ophthalmology Director of Cornea Research Program Bascom Palmer Eye Institute University of Miami Miller School of Medicine McKnight Vision Research Center 900 NW 17th St Miami Florida 33136 USA

HIGHLIGHTS

The new non-contact esthesiometer has an excellent intra-observer and inter-observer repeatability.
Corneal sensitivity threshold measurements obtained with the brill and cochet-bonnet esthesiometers are dissimilar.
The non-contact brill esthesiometer and the cochet-bonnet esthesiometer cannot be used interchangeably.

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

Primarily, to evaluate the repeatability and reproducibility of the new noncontact esthesiometer (NCE) in healthy subjects. Secondarily, the corneal sensitivity threshold measurements of the NCE were compared with those of the Cochet-Bonnet esthesiometer (CBE).

Design

Assessment reliability study.

Methods

Two examiners measured bilateral corneal sensitivity thresholds by NCE and CBE. Triple NCE measurements were performed per eye at all 5 levels, whereas single CBE measurements were performed per eye. When appropriate, NCE (mBar) and CBE (mm) measurements were converted to millinewtons (mN) for direct comparison between devices. The NCE measurement variations were calculated with the intra-class correlation coefficients (ICC) for the primary objective. For the secondary objective, Bland-Altman plots with 95% limits of agreement (95%-LoA) and Spearman's rank correlation coefficients were used to evaluate the level of agreement and linear relationship between the corneal sensitivity thresholds obtained with both devices. Generalized estimating equation models were used to account for the inter-eye correlation of the same study participant.

Results

Fifty subjects (100 eyes) aged 29 years (median) were included. There were no statistically significant differences in the pressure measured by both observers at each NCE level (all P > .05). There was a high intra-observer and inter-observer repeatability of the NCE measurements (ICC > 0.90) and a strong linear correlation (rho > 0.7) at each NCE level. The difference between the mean corneal sensitivity thresholds (mN) measured with the NCE (0.052 ± 0.021 mN) and CBE (0.046 ± 0.005 mN) was statistically significant ( P = .001). Bland-Altman analysis revealed a differential bias of +0.00578 mN (95%-LoA -0.03677 – +0.04833 mN) between threshold measurements.

Conclusions

The NCE provides reliable user-independent corneal sensitivity measurements. The NCE and CBE do not yield similar values. Thus, both devices cannot be used interchangeably.

Le texte complet de cet article est disponible en PDF.

Plan


  Supplemental Material available at AJO.com .


© 2024  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 271

P. 407-416 - mars 2025 Retour au numéro
Article précédent Article précédent
  • Clinical Characterization, Natural History, and Detailed Phenotyping of NMNAT1-Associated Leber Congenital Amaurosis
  • YOO JIN LEE, HYUN CHUL JEONG, JEONG HUN KIM, DONG HYUN JO
| Article suivant Article suivant
  • Favorable Outcomes of Patients With High-Risk Uveal Melanoma Treated With a Novel Linear Accelerator-Based Frameless Fractionated Stereotactic Radiosurgery
  • Louis Cappelli, Mehak M. Khan, Carol L. Shields, Sara E. Lally, Muhammad Sharif, Haisong Liu, Yingxuan Chen, Jade Park, Tingting Zhan, Wenyin Shi

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.