Comparing an Advanced Monofocal With a Non-diffractive Extended Depth of Focus Intraocular Lens Using a Mini-Monovision Approach - 13/02/25

Highlights |
• | This article investigated interindividual comparison of an advanced monofocal intraocular lens RAO200E and a nondiffractive extended depth of focus intraocular lens DFT015 in a mini-monovision approach. |
• | No significant difference in binocular visual acuity for far, intermediate, and near distance could be shown. |
• | Both intraocular lenses are good choices for a mini-monovision approach if spectacle independence is desired. |
Résumé |
PURPOSE |
To compare interindividual differences in visual performance of an advanced monofocal with a nondiffractive extended depth of focus intraocular lens (IOL) using a mini-monovision approach.
DESIGN |
Single-center, randomized, controlled, double-masked study.
METHODS |
In total, 48 patients (96 eyes) with bilateral age-related cataract were enrolled. One group received an advanced monofocal IOL RAO200E (RayOne EMV; Rayner) and the other group a non-diffractive extended depth of focus IOL DFT015 (Acrysof IQ Vivity; Alcon) in both eyes. Target refraction for both groups was mini-monovision. After 3 months, monocular and binocular distance corrected and uncorrected distance (CDVA/UDVA), intermediate (DCIVA/UIVA), and near visual acuity (DCNVA/UNVA); contrast sensitivity; binocular defocus curves; halometry; and Quality of Vision questionnaire scores were compared.
RESULTS |
Binocular mean CDVA, DCIVA at 66 cm, and DCNVA at 40 cm were –0.10±0.10, 0.15±0.11, and 0.32±0.16 logMAR for the RAO200E and –0.10±0.10, 0.12±0.10, and 0.27±0.16 logMAR for the DFT015, respectively, with no significant difference. A significant difference could be shown for the dominant eye in monocular DCIVA and DCNVA and for the dominant and nondominant eye in monocular UNVA, with 0.28±0.14, 0.48±0.22, 0.46±0.21, and 0.41±0.20 logMAR for the RAO200E and 0.14±0.10 ( P = .023), 0.35±0.16 ( P = .008), 0.30±0.14 ( P = .001), and 0.21±0.10 ( P = .003) logMAR for the DFT015, respectively. Significantly smaller halo size in the RAO200E group and significantly better distance-corrected defocus curve at –2.5 ( P = .031), –2.0 ( P = .03), and –1 diopters ( P = .03) of defocus in the DFT015 group could be shown.
CONCLUSIONS |
Distance corrected or uncorrected binocular visual acuity for far, intermediate, and near distance between the advanced monofocal IOL RAO200E and the non-diffractive extended depth of focus IOL DFT015, when compared in a mini-monovision setting, showed no significant differences.
Le texte complet de cet article est disponible en PDF.Plan
| Supplemental Material available at AJO.com . |
|
| Meeting Presentation: The preliminary results of this study have been presented at the ESCRS congress in Vienna in September 2023. |
Vol 271
P. 86-95 - mars 2025 Retour au numéroBienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.
Déjà abonné à cette revue ?
