S'abonner

Interventions implemented to remediate mold identified in Neonatal Intensive Care Unit (NICU) incubators, 2022 to 2023 - 24/02/25

Doi : 10.1016/j.ajic.2024.10.032 
Lacey Kovar, MPH, CIC a, , Courtney McPherson, MSN, RNC-NIC b, Jennifer Ware, RN-NIC b, Lacye Hurst, MSN, RN c, Chris Gould, MBA d, Amanda Martinez, MT (ASCP) e, Prakash Shrestha, MD f, John E. Sparks, MD b
a Infection Prevention Covenant Children’s Hospital, Lubbock, TX 
b Neonatal Intensive Care Unit Covenant Children's Hospital, Lubbock, TX 
c Risk Management Covenant Children’s Hospital, Lubbock, TX 
d Environment of Care Facilities Engineering Covenant Health, Lubbock, TX 
e Microbiology Covenant Medical Center, Lubbock, TX 
f Infection Prevention Covenant Health, Lubbock, TX 

Address correspondence to Lacey Kovar, MPH, CIC, 4002 24th St, Lubbock, TX 79410.4002 24th StLubbockTX79410

Résumé

Background

Neonatal Intensive Care Units utilize incubators to sustain core temperatures associated with transepidermal water loss. High relative humidity in incubators provides an environment for fungi to grow. In August 2022, mold was identified growing in 11 (85%) Neonatal Intensive Care Unit incubators.

Methods

A team assembled to address mold in incubators. The environment was addressed as a possible source of contamination by consulting an environmental specialist. The air handler, ducts, and environment were terminally cleaned. Specimens were collected from the contaminated incubators and the manufacturer reviewed cleaning practices. Experimental trials were conducted using the incubators to replicate mold growth after interventions.

Results

The environmental consultant approved when the space could be reoccupied. Incubators introduced to the clean environment did not grow mold. Various fungi or yeast were identified in the contaminated incubators. Opportunities to improve cleaning and replacement of parts were identified by the manufacturer. September 2022 to February 2023, 7 experimental trials were completed after cleaning the incubators. Four (36%) of the 11 contaminated incubators were placed back in use due to no fungal growth. No patient illnesses occurred.

Conclusions

The interventions implemented stopped ongoing contamination of incubators and use of previously contaminated incubators.

Le texte complet de cet article est disponible en PDF.

Highlights

Neonatal Intensive Care Unit incubators growing multiple fungal organisms.
Elimination of unknown source of fungal organisms through enviornmental remediation.
Incubator cleaning and replacement of older parts may prevent or remediate fungus.

Le texte complet de cet article est disponible en PDF.

Key Words : Fungi, Yeast


Plan


 Conflicts of interest: None to report.


© 2024  Association for Professionals in Infection Control and Epidemiology, Inc.. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 53 - N° 3

P. 387-393 - mars 2025 Retour au numéro
Article précédent Article précédent
  • Identifying high-risk central lines in critically ill children: A novel nurse-driven screening and mitigation intervention to reduce CLABSI
  • Stephanie Morgenstern, Katie Thompson, Stephanie Panton, Vivian Donnelly, Sara Pau, Kat Nelson, Lauren Booth, Taylor McIlquham, Jessica Kitlas, Christina Schumacher, Aaron M. Milstone, Meghan Bernier, Anna C. Sick-Samuels
| Article suivant Article suivant
  • Infection prevention and control recommendations for emergent congregate settings: A case of refugee settlement to “safe haven”
  • Nicole Mueller, Aimee Mikesch, Allison O’Rourke

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.