Prospective, multicenter, self-controlled clinical trial on the effectiveness and safety of a cable-transmission magnetically controlled capsule endoscopy system for the examination of upper GI diseases (with video) - 04/04/25

Doi : 10.1016/j.gie.2024.07.028 
Yuan Tian, MD 1, Shiyu Du, MD 2, Hong Liu, MD 3, Hang Yu, MD 1, Ruxue Bai, MD 2, Hui Su, MD 3, Xinyue Guo, BS 1, Yan He, BS 1, Zhenmei Song, MD 2, Yanming Chen, BS 2, Qian Li, MD 3, Jing Wang, MD 3, Wenming Huang, BS 4, Long Rong, MD 1,
1 Department of Endoscopy Center, Peking University First Hospital, Beijing, China 
2 Gastroenterology Department, China-Japan Friendship Hospital, Beijing, China 
3 Gastroenterology Department, Capital Medical University affiliated Beijing Shijitan Hospital, Beijing, China 
4 Hygea Medical Technology Co, Beijing, China 

Reprint requests: Long Rong, MD, Department of Endoscopy Center, Peking University First Hospital, No. 8 Xishiku St, Beijing 100034, China.Department of Endoscopy CenterPeking University First HospitalNo. 8 Xishiku StBeijing100034China

Abstract

Background and Aims

Many GI disorders and precancerous conditions often present asymptomatically, leading to delayed patient diagnoses and treatment interventions. In this study, we developed a novel cable-transmission magnetically controlled capsule endoscopy (CT-MCCE) system for detecting GI diseases and assessed its safety and feasibility through clinical trials.

Methods

This prospective, multicenter trial compared CT-MCCE with conventional gastroscopy in patients aged 18 to 75 years with upper GI tract diseases between October 2022 and July 2023. The primary endpoints were the evaluation of sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) in the detection of focal lesions within the esophagus, stomach, and duodenal bulb using CT-MCCE.

Results

One hundred eighty individuals (mean age, 43.1 years; 52.22% women) were recruited from 3 hospitals in China. CT-MCCE detected lesions in the esophagus with a sensitivity of 97.22%, specificity of 100%, PPV of 100%, NPV of 98.18%, and accuracy of 98.89%; detected gastric focal lesions in the entire stomach with a sensitivity of 96.81%, specificity of 98.84%, PPV of 98.91%, NPV of 96.59%, and accuracy of 97.78%; and detected lesions in the duodenal bulb with a sensitivity of 100%, specificity of 100%, PPV of 100%, NPV of 100%, and accuracy of 100%. There were no significant differences between CT-MCCE and EGD regarding the cleanliness of the upper GI tract and visibility of the upper GI mucosa. However, CT-MCCE was associated with a lower incidence of discomfort than EGD (P < .001).

Conclusions

The diagnostic performance of CT-MCCE is comparable with that of EGD in the completion of upper GI tract examinations and lesion detection. Furthermore, the improved tolerance of CT-MCCE in detecting upper GI diseases was noted without any observed adverse events. (Clinical trial registration number: ChiCTR2200063630.)

Le texte complet de cet article est disponible en PDF.

Graphical abstract




Le texte complet de cet article est disponible en PDF.

Abbreviations : CI, CT-MCCE, MCCE, NPV, PPV


Plan


© 2025  American Society for Gastrointestinal Endoscopy. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 101 - N° 4

P. 804 - avril 2025 Retour au numéro
Article précédent Article précédent
  • Evaluating the efficacy of a novel hemostatic powder compared with traditional treatments in nonvariceal upper GI bleeding: a multicenter, randomized, noninferiority study
  • Da Hyun Jung, Jun Chul Park, Joon Sung Kim, Moon Won Lee, Hyuk Lee, Gwang Ha Kim
| Article suivant Article suivant
  • Automatic endoscopic gastroplasty for the treatment of obesity: results from a prospective multicenter study (with video)
  • Ivo Boskoski, Gontrand Lopez-Nava, Asokkumar Ravishankar, Vincenzo Bove, Maria Valeria Matteo, Martina De Siena, Valerio Pontecorvi, Giulia Giannetti, Amerigo Iaconelli, Cristiano Spada, Steven E. Shamah

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.