S'abonner

Comparative evaluation of novel framework-supported 3-dimensional facial scanning using smartphone device with freehand facial scanning in patients seeking orthodontic treatment: A cross-sectional study - 26/04/25

Doi : 10.1016/j.ortho.2025.101012 
Aditya Talwar 1, , Isha Duggal 2, Harpreet Grewal 3, Neha Bhutiani 3, Navneet Singh 3, Saurabh Kaushik 3
1 Orthodontics & Dentofacial Orthopaedics, Manav Rachna Dental College, Faridabad, India 
2 AIIMS-CAPFIMS, New Delhi, India 
3 Unit of Orthodontics & Dentofacial Orthopedics, University College of Medical Sciences, New Delhi, India 

Aditya Talwar, Department of Orthodontics & Dentofacial Orthopaedics, Manav Rachna Dental College, Faridabad 121004, India.Department of Orthodontics & Dentofacial Orthopaedics, Manav Rachna Dental CollegeFaridabad121004India

Summary

Introduction

Surface anthropometric assessment of soft tissues is an ideal approach for measuring 3D facial changes with smartphone/tablet-based applications revolutionizing 3D facial acquisition. However, the scans obtained are prone to distortion and have limited repeatability due to the freehand recording of the scans in continuous image capture mode, thus also reducing their reliability. The aim was to introduce the design and operation of an innovative apparatus for acquiring 3D facial scans in a standardised, repeatable, and convenient way for young children and adults.

Material and methods

The apparatus presents a framework with a straight and scissor arm with the recommended dimension of 68×60×34cm with a 360-degree rotatory joint similar to wall-mounted X-ray systems used in dental offices. Facial scans of 15 patients aged between 19–25 years (mean age=23.13 years) were recorded using the two techniques (framework-supported [SF] and freehand [SWF]) Scandy Pro app in Apple iPad Pro. The scans were exported in .stl format and analysed using Meshlab and Viewbox 4 software for surface comparison, scan time, and mean absolute distance (MAD) between facial soft tissue landmarks.

Results

Scans using the framework (SF) showed fewer aberrations, especially in the nasolabial and periorbital areas. Zygoma R and L (0.608±1.605 and 0.503±1.191 respectively) displayed the most difference, while Point A (0.323±1.381), Pogonion (0.364±1.344), and infraorbital region R and L (0.307±0.785 and 0.362±1.089 respectively) displayed the least. With no scan interruptions, the average scan time decreased threefold to 10.14seconds for SF compared to 27.81seconds for SWF, with 12 instances of tracking loss. Superimposition analysis of SF scans shows ICC values from 0.574 to 0.882, indicating good agreement.

Conclusion

The proposed framework provides a reliable, accurate, and cost-effective alternative for 3D facial imaging using smartphone devices. It demonstrates high reproducibility and significant reductions in scan time and tracking loss. This apparatus could facilitate the routine clinical use of 3D facial scanning in orthodontics, offering portable and non-invasive solutions.

Le texte complet de cet article est disponible en PDF.

Keywords : 3D facial imaging, Orthodontics, Digital imaging, Accuracy, Reliability, Reproducibility


Plan


© 2025  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 3

Article 101012- septembre 2025 Retour au numéro
Article précédent Article précédent
  • Performance assessment of artificial intelligence chatbots (ChatGPT-4 and Copilot) for sharing insights on 3D-printed orthodontic appliances: A cross-sectional study
  • Asma Muhammad Yousuf, Fizzah Ikram, Munnal Gulzar, Rashna Hoshang Sukhia, Mubassar Fida
| Article suivant Article suivant
  • Does operator experience affect the accuracy of guided palatal miniscrew insertion via surgical guide? An in-vitro study
  • Amedeo Salomone, Mario Palone, Francesca Cremonini, Giuliano Maino, Emanuele Paoletto, Marta Cappelletti, Luca Lombardo

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.