Knoop microhardness, surface roughness, and cytotoxicity analysis of arginine-modified experimental orthodontic resins: An in vitro study - 09/05/25

Doi : 10.1016/j.ortho.2025.101014 
Pérola Costa Bitencourt Santos 1, Analia Gabriella Borges Ferraz Facury 2, Lenita Marangoni Lopes 1, Mário Alexandre Coelho Sinhoreti 2, Daniel Navarro da Rocha 3, Lourenço Correr-Sobrinho 2, Ana Rosa Costa 1, 2, José Guilherme Neves 2,
1 Herminio Ometto Foundation, Araras Dental School, Araras, SP, Brazil 
2 Department of Restorative Dentistry, Dental Materials Area, Piracicaba Dental School, State University of Campinas, FOP – UNICAMP, Piracicaba, SP, Brazil 
3 Department of Materials Engineering-SE/8, Military Institute of Engineering, Rio de Janeiro, Brazil 

José Guilherme Neves, Department of Restorative Dentistry, Dental Materials Area, Piracicaba Dental School, State University of Campinas, FOP – UNICAMP, Piracicaba, SP, BrazilDepartment of Restorative Dentistry, Dental Materials Area, Piracicaba Dental School, State University of Campinas, FOP – UNICAMPPiracicabaSPBrazil

Summary

Aim

The study aimed to evaluate the impact of incorporating 2.5%, 5%, and 7% arginine on the hardness, roughness, and cytotoxicity of 3M™ Transbond™ XT.

Material and methods

A total of 48 samples were divided into four groups (n=12): G1 – commercial resin 3M™ Transbond™ XT (TXT); G2 – TXT+2.5% arginine; G3 – TXT+5% arginine; and G4 – TXT+7% arginine. The hardness analysis was performed by a microhardness tester. The measurements of roughness were performed by a surface roughness measuring instrument. The surface morphology analysis was analyzed by digital images obtained with a scanning electron microscope (SEM). For the in vitro cytotoxicity test, dental pulp mesenchymal cells underwent a cell viability reduction assay. For statistical analysis, ANOVA (one-way/two-way) was used, followed by Tukey's test post hoc (P<0.05).

Results

There was a reduction in the hardness of experimental resins compared to 3M™ Transbond™ XT commercial resin (P < 0.05). There was no difference between concentrations of 2.5% and 5%, but there was the largest reduction in resin with 7% arginine (P < 0.05). Surface roughness analysis showed there was no statistical difference between the samples (P ≥ 0.05). SEM also did not demonstrate changes in the surface roughness of the resins. All groups exhibited good cell viability at each timepoint. After 48h, an increase was observed for groups contaning arginine (P < 0.05).Conclusion: Surface hardness was modified with when arginine incorporation - to the Transbond™ XT resin formulation. No differences were observed for surface roughness. Due to the initial cytotoxicity of the resins, precautions regarding satisfactory photopolymerization and the distance of application in relation to the gingival tissues must be adopted.

Le texte complet de cet article est disponible en PDF.

Keywords : Orthodontics, Arginine, Dental bonding, Hardness, Surface properties, Cell tracking


Plan


© 2025  CEO. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 23 - N° 4

Article 101014- décembre 2025 Retour au numéro

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.