S'abonner

Photon-counting CT-derived extracellular volume in acute myocarditis: Comparison with cardiac MRI - 02/07/25

Doi : 10.1016/j.diii.2025.03.001 
Christos Gkizas a, , Benjamin Longere a, b, Olga Sliwicka a, Aimee Rodriguez Musso a, Gilles Lemesle b, c, Cedric Croisille d, Mehdi Haidar a, Francois Pontana a, b
a Department of Cardiovascular Imaging, Heart and Lung Institute, University Hospital of Lille, 59000 Lille, France 
b INSERM UMR 1011, Institute Pasteur of Lille, EGID (European Genomic Institute for Diabetes), FR3508; Univ Lille, 59000, Lille, France 
c Cardiac Intensive Care Unit and Hemodynamic Center, Heart and Lung Institute, University Hospital of Lille, 59000, Lille, France 
d Siemens Healthineers, 33600, Bordeaux, France 

Corresponding author.

Highlights

Extracellular volume calculation using iodine maps from late enhancement by cardiac dual-source photon-counting detector computed tomography is feasible.
Excellent correlation is found between photon-counting detector computed tomography and magnetic resonance imaging for the estimation of extracellular volume in patients with myocarditis.
A two-acquisition protocol with a 5-minute delay late enhancement acquisition could accurately assess myocarditis.

Le texte complet de cet article est disponible en PDF.

Abstract

Purpose

The purpose of this study was to evaluate the feasibility and the accuracy of myocardial late iodine enhancement for extracellular volume (ECV) quantification using dual-source photon-counting detector computed tomography (PCD-CT) in patients with suspected acute myocarditis by comparison with cardiac MRI.

Materials and methods

Patients with clinical suspicion of myocarditis who were referred for coronary CT angiography (CCTA) to exclude coronary artery disease were included in this retrospective study. All patients underwent CCTA examination using a first-generation PCD-CT, which included slate iodine enhancement images. ECV was calculated from the iodine ratio of the myocardium to the blood pool on late iodine enhancement PCD-CT images. A comprehensive cardiac MRI protocol was used as the reference method to confirm myocarditis according to the Lake Louise 2018 criteria. All subjects underwent CCTA using PCD-CT and cardiac MRI within 24 h. The mean dose-length product of late enhancement PCD-CT scanning was calculated. Correlations between ECV PCD-CT (endocardial, epicardial, midcardial, and global), cardiac MRI-LGE, and right and left ventricular ejection fractions were assessed using Pearson correlation test. ECV values derived from PCD-CT and those from cardiac MRI were compared using Bland Altman plots and linear regression analysis. Areas under the receiver operating characteristic curves (AUCs) were used to determine the optimal thresholds of ECV-PCD-CT and ECV-MRI for differentiating patients with myocarditis from those not meeting the Lake Louise criteria.

Results

Thirty-two patients were included. There were 19 men and 13 women with a mean age of 35.9 ± 15.0 (standard deviation [SD]) years; age range: 21–51). The mean dose-length product of late enhancement PCD-CT scanning was 96 ± 32 (SD) mGy.cm. No significant differences in mean global ECV were found between ECV calculated with the PCD-CT (29.4 ± 4.5 [SD] %) and that calculated with cardiac MRI (30.0 ± 4.1 [SD] %) (P = 0.69). ECV-CT was greater in patients with cardiac MRI-confirmed myocarditis (31.65 ± 3.6 [SD] %) by comparison with those with normal findings (25.6 ± 3.2 [SD] %) (P < 0.01). ECV-CT strongly correlated with LGE mass (r = 0.82) and showed strong segmental correlation with ECV-MRI (basal: r = 0.95; mid-ventricular: r = 0.91). An ECV-CT threshold of 26.9 % yielded an AUC of 0.95 (95 % CI: 0.84–1.00) for the diagnosis of myocarditis.

Conclusion

Calculation of ECV using iodine maps derived from late iodine enhancement cardiac PCD-CT images is both feasible and accurate at low radiation doses. PCD-CT appears as a promising non-invasive imaging modality for the diagnostic and prognostic assessment of acute myocarditis in the setting of chest pain.

Le texte complet de cet article est disponible en PDF.

Keywords : Coronary artery disease, Computed tomography, Dual-source photon counting, Extracellular volume, Myocarditis

Abbreviation : AUC, DLP, CAD, CAD-RADS, CT, CCTA, ECG, ECV, EF, ICC, LGE, LIE, LV, LVEF, MRI, PCD, PPV, SD


Plan


© 2025  Société française de radiologie. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 106 - N° 7-8

P. 255-263 - juillet 2025 Retour au numéro
Article précédent Article précédent
  • Cardiac magnetic resonance imaging in the follow-up of patients with Fabry cardiomyopathy
  • Jules Senlis, Fabien Labombarda, Julien Burel, Arthur Flouriot, Sébastien Normant, Matthieu Demeyere, Olivier Lairez, Soraya El Ghannudi, Alexis Jacquier, Olivier Ghekiere, Farah Cadour, Jean-Nicolas Dacher
| Article suivant Article suivant
  • Generative T2*-weighted images as a substitute for true T2*-weighted images on brain MRI in patients with acute stroke
  • Antoine Pelcat, Alice Le Berre, Wagih Ben Hassen, Clement Debacker, Sylvain Charron, Bertrand Thirion, Laurence Legrand, Guillaume Turc, Catherine Oppenheim, Joseph Benzakoun

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.