S'abonner

Spirometry and impulse oscillometry in the diagnosis of cough variant asthma in children - 22/07/25

Doi : 10.1016/j.rmed.2025.108255 
Chunyu Tian a , Shiqiu Xiong b , Xin Song a , Shuo Li a , Yantao Zhang a , Xinmei Jiang a , Xinyue Hou a , Yifan Zhang a , Chuanhe Liu a,
a Capital Center for Children's Health, Capital Medical University, Beijing, China 
b Xi'an Children's Hospital, Shanxi, China 

Corresponding author. No.2 Yabao Road, Chaoyang District, Beijing, 100020, China.No.2 Yabao RoadChaoyang DistrictBeijing100020China

Abstract

Objective

This study aimed to assess the diagnostic utility of spirometry and impulse oscillometry, focusing on their correlation and diagnostic advantages, in children with cough variant asthma (CVA).

Methods

This study included children aged 5–12 years with a diagnosis of CVA who underwent sequential IOS and spirometry pulmonary function with bronchodilation (BD) tests. A control group of healthy children was matched. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was calculated to assess the discriminatory potential of these spirometry and IOS parameters for CVA. The correlation and diagnostic consistency between spirometry and IOS parameters were compared.

Results

A total of 177 patients with CVA and 45 control subjects were included. The ROC curve results for pre-BD parameters and the improvement rate showed that the combinations of “pre-MMEF(%pred) and MMEF” and “pre-Z5 (%pred) and -Z5 (%)” achieved the highest AUC value of 0.892 and 0.836, with threshold probabilities of 0.868, 0.786, respectively. The AUC values of these combined parameters surpassed those of individual ones. The correlation between spirometry and IOS parameters showed that pre-FEF25 (%pred) has a moderately negative correlation with pre-Z5 (%pred) and pre-R5 (%pred) (r = −0.415, −0.404; P < 0.001), FEF75 % has a weak positive correlation with -Z5 %, -R5 %(r = 0.154, 0.155; P < 0.05). The comparison of diagnostic consistency between pre-BD spirometry and pre-BD IOS parameters showed a weak correlation(kappa = 0.150, P = 0.007).

Conclusions

The changes in spirometry and IOS parameters during the BD test provided valuable diagnostic information for CVA and can help pediatricians accurately identify CVA in children.

Le texte complet de cet article est disponible en PDF.

Highlights

CVA has been one of the most common causes of chronic cough worldwide.
The diagnosis of CVA in children remains challenging.
In our study, the changes and correlations of spirometry and IOS during BD tests provide valuable diagnostic information for CVA in children.

Le texte complet de cet article est disponible en PDF.

Keywords : Children, Cough variant asthma, Diagnosis, spirometry, Impulse oscillometry

Abbreviations : AUC, AX, BD, HR, BPT, Fres, FeNO, FEV1, FVC, FEF25, FEF50, FEF75, GINA, ICS, IOS, MMEF, PEF, R5, R20, ROC, (SAD), X5, Z5


Plan


© 2025  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 246

Article 108255- septembre 2025 Retour au numéro
Article précédent Article précédent
  • Sensitivity and specificity of various lung function parameters recommended for phenotyping COPD in clinical practice
  • Roberto Walter Dal Negro, Paola Turco, Massimiliano Povero
| Article suivant Article suivant
  • Natural history and burden of refractory Mycobacterium avium complex pulmonary disease: Insights from the US Bronchiectasis and Nontuberculous Mycobacterial Research Registry
  • Timothy R. Aksamit, Radmila Choate, David M. Mannino, Amanda E. Brunton, Ping Wang, Mariam Hassan

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.