S'abonner

Reference ranges for liver function tests in pregnancy controlling for maternal characteristics - 31/07/25

Doi : 10.1016/j.ajog.2025.06.056 
Hannah R. Judah, MD a, Robert A. Rigby, PhD b, Mikis D. Stasinopoulos, PhD b, Konstantinos Pateras, PhD c, Mussarat N. Rahim, MD d, Michael A. Heneghan, MD d, Kypros H. Nicolaides, MD a, Nikos A. Kametas, MD a,
a Fetal Medicine Research Institute, King’s College Hospital, London, United Kingdom 
b School of Computing and Mathematical Sciences, University of Greenwich, London, United Kingdom 
c Laboratory of Epidemiology, Applied Artificial Intelligence and Biostatistics, Faculty of Public and One Health, University of Thessaly, Thessaly, Greece 
d Institute of Liver Studies, King’s College Hospital, London, United Kingdom 

Corresponding author: Nikos A. Kametas, MD.
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Thursday 31 July 2025
Cet article a été publié dans un numéro de la revue, cliquez ici pour y accéder

Abstract

Background

Liver dysfunction complicates 3% of pregnancies, and prompt diagnosis reduces severe maternal and perinatal morbidity and mortality. Recognition of liver dysfunction relies on the creation of reference ranges. Outside pregnancy, factors such as age and sex have been shown to affect liver biomarkers. However, despite recommendations for age- and sex-adjusted reference ranges for liver function tests, these have not been widely adopted clinically. In pregnancy, only a few studies have examined changes of liver function tests with gestation, and none of them have controlled for maternal demographic characteristics.

Objective

This study aimed to (1) provide reference ranges for liver function tests in a large population of uncomplicated pregnancies after adjusting for the effect of gestational age and maternal demographic characteristics on the median and measures of dispersion and shape (skewness and kurtosis) of the distribution of these variables, and (2) create an online calculator of z-scores of maternal liver function tests using the above-mentioned methodology.

Study Design

This was a cross-sectional study of healthy women undergoing routine antenatal ultrasound scans at 11+0 to 13+6 weeks’ gestation (visit 1), 19+0 to 24+6 weeks (visit 2), 30+0 to 34+6 weeks (visit 3), and 35+0 to 37+6 weeks (visit 4). Women with a history of liver dysfunction or adverse pregnancy outcomes were excluded from the analysis. We measured the following variables: ALP (alkaline phosphatase), ALT (alanine aminotransferase), AST (aspartate aminotransferase), GGT (gamma-glutamyl transferase), total bilirubin, and ALB (albumin). The assessment of the distribution of liver function tests across gestational age (controlling for maternal characteristics) was performed using the generalized additive model for location, scale, and shape, with the gamlss R package, which allows the implementation of distributions other than the normal distribution.

Results

There were 3451 women who agreed to participate in the study and had uncomplicated pregnancies. Women participated only once in the study, with 805, 860, 886, and 900 women attending visits 1, 2, 3, and 4, respectively. The location parameter of the distribution of the liver function test variables is independently predicted by gestational age and ethnicity for all variables, by maternal body mass index for all variables except ALB, by maternal age for all variables except ALT-AST ratio and GGT, by maternal parity for all variables except total bilirubin and ALP, by maternal smoking for total bilirubin and ALB, and by maternal weight for ALP. The scale parameter of the distribution is also independently predicted by gestational age for all variables except ALP, maternal body mass index for ALT, AST, GGT, and ALP, maternal age and ethnicity for GGT, and maternal parity for ALT and AST. In contrast, the skewness and kurtosis of liver function tests are influenced nonuniformly by gestational age, maternal ethnicity, body mass index, age, and parity. An online calculator of z-scores for the above-mentioned variables is given at life/.

Conclusion

Assessing whether a pregnant woman’s liver function tests deviate from the expected normal values necessitates adjusting for gestational age and maternal demographic characteristics, both for the median and measures of dispersion and shape of the distribution.

Le texte complet de cet article est disponible en PDF.

Video


(36.82 Mo)

Le texte complet de cet article est disponible en PDF.

Key words : alanine aminotransferase, albumin, alkaline phosphatase, aspartate aminotransferase, dispersion and shape of the distribution, gamma-glutamyl transferase, generalized additive model for location, scale, and shape, liver function tests, maternal characteristics, pregnancy, reference ranges, total bilirubin


Plan


 H.R.J. and R.A.R. share first authorship.
 The authors report no conflict of interest.
 The study was supported by a grant from the Fetal Medicine Foundation (U.K. Charity No: 1037116).
 Data availability statement: Research data are not shared.
 Cite this article as: Judah HR, Rigby RA, Stasinopoulos MD, et al. Reference ranges for liver function tests in pregnancy controlling for maternal characteristics. Am J Obstet Gynecol 2025;XX:x.ex–x.ex.


© 2025  Publié par Elsevier Masson SAS.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.