S'abonner

Vancouver B2 Periprosthetic femoral fractures around cemented polished taper-slip stems – how should we treat these? A systematic scoping review and algorithm for management - 29/08/25

Doi : 10.1016/j.otsr.2024.104110 
Benjamin Schapira , Suroosh Madanipour, Padmanabhan Subramanian
 Trauma and Orthopaedics, Royal Free NHS Foundation Trust, Pond Street, London, NW3 2QG, United Kingdom 

Corresponding author.

Abstract

Background

Periprosthetic femoral fractures (PFF) are a challenging complication of hip arthroplasty surgery, posing a high risk of morbidity, mortality and reoperation. The Vancouver Classification describes a B2 PFF around a loose stem with sufficient bone stock. In recent years, the number of B2 PFFs and cementation of femoral stems have increased substantially.

Hypothesis

This systematic scoping review aimed to review the options available to surgeons in managing Vancouver B2 PFFs around cemented polished taper-slip (PTS) stems and establish an algorithm of management to treat varying fracture presentations.

Patients and methods

This study reviewed articles reporting on Vancouver B2 PFFs around cemented femoral stems between 2012 and 2022. Data extracted included: patient demographics, index prosthesis, surgical intervention and decision for treatment, operation time, transfusion requirement, length of hospital stay, post-operative rehabilitation protocol, mobility outcomes, radiological outcomes, complications, reoperations, mortality rates and follow-up.

Results

In total, fourteen studies met all inclusion criteria including 552 cases. Mean patient age was 76.8 years with a male:female ratio 1:1.83 and median follow-up 49.2 months. Treatment options included open reduction and internal fixation (ORIF), revision arthroplasty using cementless modular and monoblock long-stems ± distal locking, cement-in-cement revision and cemented long-stem revision ± impaction bone grafting.

Conclusions

Management of B2 PFFs around cemented PTS stems is complex and aims to obtain stable fracture and stem fixation. Options include ORIF, cement-in-cement and cementless revision. The optimal choice depends on a combination of patient, fracture and surgeon factors. This review has proposed an algorithm to aid in decision making.

Level of evidence

III; systematic scoping review.

Le texte complet de cet article est disponible en PDF.

Keywords : B2 periprosthetic femoral fracture, Vancouver B2, Cement, Polished taper-slip stem


Plan


Crown Copyright © 2024  Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 111 - N° 5

Article 104110- septembre 2025 Retour au numéro
Article précédent Article précédent
  • Double-approach synovectomy (anterior and posterior) for diffuse pigmented villonodular synovitis of the knee: Adjuvant treatment, functional and radiographic outcomes
  • Florian Triscos, Dinah Bronstein, Julien Berhouet, Louis-Romée Le Nail, Ramy Samargandi
| Article suivant Article suivant
  • NCB-PP® locking plates outcomes in the treatment of periprosthetic femoral fractures. Analysis of a retrospective cohort of 89 patients
  • Batiste Santoni, Marie Le Baron, Pascal Maman, Richard Volpi, Xavier Flecher

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2025 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.