High flow nasal cannula and low level continuous positive airway pressure have different physiological effects during de novo acute hypoxemic respiratory failure - 08/01/26

Doi : 10.1186/s13613-024-01408-w 
Samuel Tuffet 1, 2, 3 , Mohamed Ahmed Boujelben 2, 3, 4, Anne-Fleur Haudebourg 2, 3, 4, Tommaso Maraffi 2, 3, 5, François Perier 6, Pascale Labedade 2, 4, Elsa Moncomble 2, 3, 4, Ségolène Gendreau 2, 3, 4, Matthieu Lacheny 4, Emmanuel Vivier 1, 2, Armand Mekontso-Dessap 2, 3, 4, Guillaume Carteaux 2, 3, 4
1 Hôpital Saint Joseph Saint Luc, Médecine Intensive Réanimation, 20 quai Claude Bernard, Lyon, France 
2 Groupe de Recherche Clinique CARMAS, Faculté de Santé, Université Paris Est-Créteil, 94010, Créteil Cedex, France 
3 INSERM U955, Institut Mondor de Recherche Biomédicale, 94010, Créteil Cedex, France 
4 CHU Henri Mondor-Albert Chenevier, Service de Médecine Intensive Réanimation, Assistance Publique- Hôpitaux de Paris, 51, Avenue du Maréchal de Lattre de Tassigny, 94010, Créteil Cedex, France 
5 Service de Médecine Intensive-Réanimation, Centre Hospitalier Intercommunal de Créteil, Créteil, France 
6 Service de réanimation, Centre Hospitalier de La Rochelle, La Rochelle, France 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Large tidal volumes during de novo acute hypoxemic respiratory failure (AHRF) may promote patient self-inflicted lung injury. Tidal volume assessment under high flow nasal cannula (HFNC) is not routinely feasible at the bedside. Our objective was to determine whether tidal volume during low-level continuous positive airway pressure (CPAP) could predict tidal volume during HFNC and to compare the physiological effects of HFNC and low-level CPAP.

Methods

Prospective, single-center study including 29 de novo AHRF patients treated with HFNC (50 to 60 L.min − 1 ). Patients were monitored using electrical impedance tomography during HFNC then CPAP at 4 cmH 2 O. Tidal volume during HFNC was calculated based on tidal impedance variation. The ability of tidal volume under low-level CPAP to predict tidal volume under HFNC was explored using Bland-Altman analysis. CPAP and HFNC were compared in terms of tidal volume, minute ventilation, respiratory comfort, dyspnea, oxygenation, ventilation distribution, end-expiratory lung volume, thoraco-abdominal asynchrony and recruitment.

Results

Under HFNC, patients had a tidal volume of 6.6 (5.9–8.7) mL.kg − 1 PBW. 20 (69%) patients exhibited a tidal volume between 4 and 8 mL.kg − 1 PBW, while in 5 (17%) patients it exceeded 9 mL.kg − 1 PBW. Tidal volume under CPAP was higher (9.4 (8.3–11) mL.kg − 1 PBW, p   <  0.001). Tidal volumes under CPAP and under HFNC were modestly correlated (Spearman r  = 0.50, p  = 0.005). Bland-Altman analysis showed a bias of 2.4 mL.kg − 1 , with limits of agreement ranging from − 1.1 mL.kg − 1 to 5.9 mL.kg − 1 . Nevertheless, a larger ( >  11.5 mL.kg − 1 PBW) tidal volume under low-level CPAP predicted a larger ( >  9 mL.kg − 1 PBW) tidal volume under HFNC with 80% sensitivity and 96% specificity. Low-level CPAP was associated with increased minute ventilation, end-expiratory lung volume, and oxygenation as compared to HFNC. It decreased signs of respiratory distress in the most severe patients but was associated with lower comfort compared to HFNC.

Conclusion

Among ICU patients with de novo AHRF, tidal volume under HFNC was mostly protective. Tidal volume during CPAP at 4 cmH 2 O did not predict tidal volume during HFNC. Such low-level CPAP was associated with increased tidal volume, minute ventilation, end-expiratory volume, and oxygenation.

Trial registration

ClinicalTrials.gov ID NCT03919331. Registration date: 2019-03-26.

Le texte complet de cet article est disponible en PDF.

Keywords : Acute hypoxemic respiratory failure, High flow nasal cannula, Continuous positive airway pressure, Noninvasive ventilation, Respiratory support


Plan


© 2024  The Author(s) 2024. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 14 - N° 1

Article 171- 2024 Retour au numéro
Article précédent Article précédent
  • Early reduction in gut microbiota diversity in critically ill patients is associated with mortality
  • Hannah Wozniak, Nadia Gaïa, Vladimir Lazarevic, Christophe Le Terrier, Tal Sarah Beckmann, Eleonora Balzani, Martin Urner, Jérôme Pugin, Jacques Schrenzel, Claudia-Paula Heidegger, Gut Microbiota working group, Lorin Fröhlich, Tommaso Rochat Negro, Tania Soccorsi, Noémie Suh, Aurélie Perret, Chiraz Chaabane

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.