Passive leg raise testing effectively reduces fluid administration in septic shock after correction of non-compliance to test results - 08/01/26

Doi : 10.1186/s13613-016-0225-6 
Arjanne Rameau 1 , Eldert de With 1 , Evert Christiaan Boerma 1
1 Department of Intensive Care, Medical Centre Leeuwarden, Henrie Dunantweg 2, 8934 AD, Leeuwarden, The Netherlands 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Fluid resuscitation is considered a cornerstone of shock treatment, but recent data have underlined the potential hazards of fluid overload. The passive leg raise (PLR) test has been introduced as one of many strategies to predict ‘fluid responsiveness.’ The use of PLR testing is applicable to a wide range of clinical situations and has the potential to reduce fluid administration, since PLR testing is based upon (reversible) autotransfusion. Despite these theoretical advantages, data on the net effect on fluid balance as a result of PLR testing remain scarce.

Methods

We performed a prospective single-center multi-step interventional study in patients with septic shock to evaluate the effect of implementation of PLR testing on the fluid balance (FB) 48 hours after ICU admission. All patients were equipped with a PiCCO® device for pulse contour analysis to guide fluid administration. An increase in stroke volume (SV) ≥ 10% was considered a positive test result.

Results

Before introduction of PLR testing, 21 patients were prospectively included in period 1 with a median FB of 4.8 [3.3–7.8]L. After an extensive training program, PLR testing was introduced and 20 patients were included in period 2. Median FB was 4.4 [3.3–7.5]L and did not differ from period 1 ( p = 0.72). Further analysis revealed that non-compliance to the PLR test result was 44%. These findings were discussed with all ICU doctors and nurses. By consensus, non-compliance to the PLR test result was identified as the main reason for unsuccessful implementation of PLR testing. After this evaluation, 19 patients were included in period 3 under equal conditions as in period 2. In this period, median FB was 3.1 [1.5–4.9]L and significantly reduced in comparison with periods 1 and 2 ( p = 0.016 and p = 0.023, respectively). Non-compliance was 9% and significantly lower than in period 2 ( p = 0.009).

Conclusion

Implementation of PLR testing in patients with septic shock reduced fluid administration in the first 48 hours of ICU admission significantly and substantially. To achieve this endpoint, substantial non-compliance of ICU team members had to be addressed. Fluid administration despite a negative PLR test was the most common form of non-compliance.

Le texte complet de cet article est disponible en PDF.

Keywords : Sepsis, Fluid administration, Passive leg raise test, Knowledge-to-care gap, Non-compliance, Implementation


Plan


© 2017  The Author(s) 2017. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 7 - N° 1

Article 2- 2017 Retour au numéro
Article précédent Article précédent
  • A hypoperfusion context may aid to interpret hyperlactatemia in sepsis-3 septic shock patients: a proof-of-concept study
  • Leyla Alegría, Magdalena Vera, Jorge Dreyse, Ricardo Castro, David Carpio, Carolina Henriquez, Daniela Gajardo, Sebastian Bravo, Felipe Araneda, Eduardo Kattan, Pedro Torres, Gustavo Ospina-Tascón, Jean-Louis Teboul, Jan Bakker, Glenn Hernández
| Article suivant Article suivant
  • Invasive fungal tracheobronchitis in mechanically ventilated critically ill patients: underlying conditions, diagnosis, and outcomes
  • Chun-Yu Lin, Wei-Lun Liu, Che-Chia Chang, Hou-Tai Chang, Han-Chung Hu, Kuo-chin Kao, Ning-Hung Chen, Ying-Jen Chen, Cheng-Ta Yang, Chung-Chi Huang, George Dimopoulos

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.