Early prediction of noninvasive ventilation failure in COPD patients: derivation, internal validation, and external validation of a simple risk score - 08/01/26

Doi : 10.1186/s13613-019-0585-9 
Jun Duan 1 , Shengyu Wang 2, Ping Liu 3, Xiaoli Han 1, Yao Tian 2, Fan Gao 2, Jing Zhou 2, Junhuan Mou 3, Qian Qin 3, Jingrong Yu 3, Linfu Bai 1, Lintong Zhou 1, Rui Zhang 1
1 Department of Respiratory and Critical Care Medicine, The First Affiliated Hospital of Chongqing Medical University, Youyi Road 1, Yuzhong District, 400016, Chongqing, People’s Republic of China 
2 Department of Pulmonary and Critical Care Medicine, The First Affiliated Hospital of Xi’an Medical University, 710077, Xi’an, People’s Republic of China 
3 Department of Respiratory and Critical Care Medicine, The People’s Hospital of Changshou, 401220, Chongqing, People’s Republic of China 

Bienvenue sur EM-consulte, la référence des professionnels de santé.
Article gratuit.

Connectez-vous pour en bénéficier!

Abstract

Background

Early identification of noninvasive ventilation (NIV) failure is a promising strategy for reducing mortality in chronic obstructive pulmonary disease (COPD) patients. However, a risk-scoring system is lacking.

Methods

To develop a scale to predict NIV failure, 500 COPD patients were enrolled in a derivation cohort. Heart rate, acidosis (assessed by pH), consciousness (assessed by Glasgow coma score), oxygenation, and respiratory rate (HACOR) were entered into the scoring system. Another two groups of 323 and 395 patients were enrolled to internally and externally validate the scale, respectively. NIV failure was defined as intubation or death during NIV.

Results

Using HACOR score collected at 1–2 h of NIV to predict NIV failure, the area under the receiver operating characteristic curves (AUC) was 0.90, 0.89, and 0.71 for the derivation, internal-validation, and external-validation cohorts, respectively. For the prediction of early NIV failure in these three cohorts, the AUC was 0.91, 0.96, and 0.83, respectively. In all patients with HACOR score > 5, the NIV failure rate was 50.2%. In these patients, early intubation (<  48 h) was associated with decreased hospital mortality (unadjusted odds ratio = 0.15, 95% confidence interval 0.05–0.39, p   <  0.01).

Conclusions

HACOR scores exhibited good predictive power for NIV failure in COPD patients, particularly for the prediction of early NIV failure (< 48 h). In high-risk patients, early intubation was associated with decreased hospital mortality.

Le texte complet de cet article est disponible en PDF.

Keywords : COPD exacerbations, Noninvasive ventilation, Critical care

Keywords : Medical and Health Sciences, Cardiorespiratory Medicine and Haematology


Plan


 Jun Duan, Shengyu Wang and Ping Liu contributed equally to the study


© 2019  The Author(s) 2019. Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 9 - N° 1

Article 108- 2019 Retour au numéro
Article précédent Article précédent
  • Serum sodium and intracranial pressure changes after desmopressin therapy in severe traumatic brain injury patients: a multi-centre cohort study
  • A. Harrois, J.R. Anstey, F.S. Taccone, A.A. Udy, G. Citerio, J. Duranteau, C. Ichai, R. Badenes, J.R. Prowle, A. Ercole, M. Oddo, A. Schneider, M. van der Jagt, S. Wolf, R. Helbok, D.W. Nelson, M.B. Skrifvars, D.J. Cooper, R. Bellomo, The TBI Collaborative
| Article suivant Article suivant
  • Growth differentiation factor 15 and early prognosis after out-of-hospital cardiac arrest
  • Ferran Rueda, Germán Cediel, Cosme García-García, Júlia Aranyó, Marta González-Lopera, M. Cruz Aranda Nevado, Judith Serra Gregori, Teresa Oliveras, Carlos Labata, Marc Ferrer, Nabil El Ouaddi, Antoni Bayés-Genís

Bienvenue sur EM-consulte, la référence des professionnels de santé.

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.