S'abonner

Virtual surgical planning and 3D custom-made implants in the management of orbital floor fractures: A case control study - 25/01/26

Doi : 10.1016/j.jormas.2026.102718 
Stefania Troise a, Federica Calabria a, , Raffaele Spinelli a, Silvia De Masi a, Sara Tramontano a, Vincenzo Abbate a, Paola Bonavolontà a, Giovanni Salzano a, Gianluca Renato De Fazio a, Antonio Romano a, Luigi Angelo Vaira b, Giuseppe Consorti c, Carlos Navarro Cuellar d, Giovanni Dell'Aversana Orabona a
a Maxillofacial Surgery Unit, Department of Neurosciences, Reproductive and Odontostomatological Sciences, University Federico II of Naples, Naples, Italy 
b Maxillofacial Surgery Unit, University Hospital of Sassari, Sassari, Italy 
c Maxillo-Facial Surgery Unit, Azienda Ospedaliera Universitaria "Ospedali Riuniti di Ancona," Umberto I, Ancona, Italy 
d Department of Oral and Maxillofacial Surgery, Hospital General Universitario Gregorio Marañón, 28007 Madrid, Spain 

Corresponding author at: Department of Neurosciences, Maxillofacial Surgery Unit, Reproductive and Odontostomatological Sciences, University of Naples Federico II, Naples 33100, Italy. Department of Neurosciences, Maxillofacial Surgery Unit, Reproductive and Odontostomatological Sciences University of Naples Federico II Naples 33100 Italy

Abstract

Background

Orbital floor fractures are among the most frequent facial injuries, and precise reconstruction is essential to prevent both functional and aesthetic complications. Virtual Surgical Planning (VSP) combined with pre-shaped titanium mesh has transformed orbital reconstruction. This study aimed to evaluate whether VSP-assisted surgery with pre-modeled mesh provides greater accuracy and reduced operative times compared with conventional intraoperative mesh shaping.

Methods

A case–control study was performed on 52 patients treated at the “Federico II” University Hospital of Naples for large pure orbital floor fractures. Twenty-four patients (Group A) underwent VSP-assisted reconstruction using a preformed titanium mesh, while twenty-eight patients (Group B) received conventional intraoperative mesh modeling. Operative time, postoperative diplopia, infraorbital sensory disturbance, mesh malposition, screw loosening, and infection were compared in the two groups. Clinical and radiological follow-up was conducted at 12 months.

Results

Median operative time was significantly shorter in Group A compared with Group B (55 min [IQR 50–65] vs. 110 min [IQR 98–125]; p < 0.001). Persistent diplopia occurred in 4 % of patients in Group A and 28.6 % in Group B ( p = 0.028). Implant malposition was observed exclusively in Group B (25 % vs. 0 %; p = 0.011). Other postoperative complications, including infraorbital nerve alterations, eyelid malposition, wound dehiscence, screw loss, and infection, were more frequent in Group B but did not reach statistical significance. No cases of postoperative ocular motility limitation or iatrogenic fracture were observed in either group.

Conclusions

VSP with pre-modeled titanium mesh significantly reduces operative time and postoperative complications, enhancing reconstructive precision and outcomes in orbital floor fracture management. This virtual protocol is useful for reducing the costs and waiting times of custom-made implants, manufactured by external companies.

Le texte complet de cet article est disponible en PDF.

Keywords : Orbital floor fractures, Virtual surgical planning, 3D printing, Digital workflow, Patient-specific-implants, Case-control study


Plan


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 127 - N° 3

Article 102718- juin 2026 Retour au numéro
Article précédent Article précédent
  • AI-assisted translation in oral and maxillofacial surgery: A comparative evaluation
  • Murillo Martins Pinto, Erick Elienai Reis Araújo, Zacharie Rahhal, Dani Stanbouly, Ricardo Grillo
| Article suivant Article suivant
  • Orthognathic surgery in instability of the TMJ using surgical guides and customized plates: 3 case reports
  • Kiatanant Boonsiriseth, Nutnicha Naknual, Chedtha Puncreobutr, Sukkarn Themkumkwun

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.