S'abonner

The match 2 study: Robotic assisted bronchoscopy with integrated imaging with assessment of digital tomosynthesis (DT) and augmented fluoroscopy (AF): Three-Dimensional accuracy as confirmed by cone beam computed tomography (CBCT) - 23/02/26

Doi : 10.1016/j.rmed.2026.108693 
Amit K. Mahajan a, , Duy K. Duong a , Johanna Cortes b , Krish Bhadra b
a Inova Interventional Pulmonology and Thoracic Surgery, Department of Surgery, Inova Schar Cancer Institute, Inova Fairfax Hospital, Falls Church, VA, USA 
b CHI Memorial Rees Skillern Cancer Institute, CHI Memorial Hospital, Chattanooga, TN, USA 

Corresponding author.

Abstract

Purpose

Robotic-assisted bronchoscopy (RAB) with embedded digital tomosynthesis (DT) provides real-time, intraoperative nodule localization. This study examines the performance of RAB with embedded DT and integrated AF to achieve tool-in-lesion (TIL) confirmation via cone beam computer tomography (CBCT).

Methods

This was a prospective, bicentric, single-arm, non-randomized observational trial. Thirty-one patients with peripheral pulmonary nodules underwent RAB with embedded DT. Navigation was guided by DT and augmented fluoroscopy (AF). Primary endpoints were successful navigation to target lesions and successful TIL as confirmed by CBCT. Secondary endpoints included diagnostic yield based on the strict Delphi consensus definition of diagnostic yield along with serious device or procedure-related adverse events.

Results

Thirty-one patients were enrolled across two sites. Thirty-one lung nodules were successfully biopsied. The mean lesion size measured by longest cross-sectional diameter was 16 mm (±6.7 mm). DT demonstrated TIL in 30 of 31 nodules (96.7 %), with one case resulting in tool-touching-lesion (TTL). Of the 30 nodules demonstrating TIL by DT, TIL was confirmed in 29 nodules by CBCT (concordance rate of 96.7 %). Overall TIL confirmed by CBCT was 29 of 31 nodules (93.5 %). A diagnosis was obtained in 30 of 31, resulting in a 96.7 % diagnostic yield by strict definition. Pneumothorax occurred in 1 of 31 cases (3 %).

Conclusions

RAB with embedded DT demonstrated a high rate of TIL confirmed by CBCT. The strong concordance between the DT with AF and CBCT demonstrates the reliability of DT and AF for real-time intraprocedural guidance.

Le texte complet de cet article est disponible en PDF.

Highlights

Thirty-one patients with pulmonary nodules underwent robotic assisted bronchoscopy (RAB) with embedded digital tomosynthesis (DT).
Overall TIL confirmed by cone beam computer tomography (CBCT) was 29 of 31 nodules (93.5 %).
A diagnosis was obtained in 30 of 31, resulting in a 96.7 % diagnostic yield by strict definition.
Pneumothorax occurred in 1 of 31 cases (3 %).
The strong concordance between the DT with AF and CBCT demonstrates the reliability of DT and AF for real-time intraprocedural guidance.

Le texte complet de cet article est disponible en PDF.

Keywords : Digital lung tomosynthesis, Cone beam computed tomography, Tool-in-lesion, Bronchoscopy


Plan


© 2026  Elsevier Ltd. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 253

Article 108693- mars 2026 Retour au numéro
Article précédent Article précédent
  • Dynamic ultrasound evaluation of inferior vena cava and lung B-lines predicts intradialytic hypotension in critically ill AKI patients
  • Débora Soares, Conrado Lysandro, José Hermógenes Rocco Suassuna, Renata de Souza Mendes
| Article suivant Article suivant
  • Side versus adverse effects of elexacaftor/tezacaftor/ivacaftor therapy in people with CF
  • J.B.A. Gorgels, J. Koopman, E.C. van der Hout, R.W. Hofland, H.G.M. Heijerman, I. Bronsveld

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.