S'abonner

Developing a Multivariable Prediction Model to Identify a High-Volume Patent Ductus Arteriosus in Neonates Born Extremely Preterm - 08/04/26

Doi : 10.1016/j.jpeds.2025.114965 
Amy A. Hobson, DO 1, Daniel Dagle, BS 1, Craig G. Rusin, PhD 2, Christopher J. Rhee, MD, MS 3, Sebastian I. Acosta, PhD 2, Patrick J. McNamara, MB, BCH 1, 4, Danielle R. Rios, MD, MS 1, ⁎
1 Division of Neonatology, Department of Pediatrics, University of Iowa, Iowa City, IA 
2 Division of Cardiology, Department of Pediatrics, Baylor College of Medicine, Houston, TX 
3 Division of Neonatology, Department of Pediatrics, Baylor College of Medicine, Houston, TX 
4 Department of Internal Medicine, University of Iowa, Iowa City, IA 

∗ Reprint requests: Danielle R Rios, MD, MS, University of Iowa, 200 Hawkins Dr, 8805 JPP, Iowa City, IA 52242. University of Iowa 200 Hawkins Dr 8805 JPP Iowa City IA 52242

Abstract

Objective

To create a clinical model to predict presence of a high-volume, hemodynamically significant patent ductus arteriosus (PDA) in premature infants.

Study design

A single-center retrospective cohort analysis was conducted in infants < 27 weeks gestational age who received targeted neonatal echocardiography (TNE) screening for hemodynamically significant PDA. TNEs were categorized as high-volume shunt (score ≥ 9) or no PDA/low-volume shunt (score ≤ 2) using the modified Iowa PDA score. Continuous vital sign data were evaluated in 5-minute increments for the hour preceding each TNE. A Fourier transform of the arterial blood pressure waveform was used to extract features quantifying the waveform shape. Predictor variables were used to create a logistic regression model to classify each 5-minute window as high-volume PDA or no PDA/low-volume shunt.

Results

The model included 173 TNEs (37 high-volume shunt, 136 no PDA/low-volume shunt) from 90 patients. Mean airway pressure was higher in the high-volume shunt group ( P < .01), but other variables were similar. Once the best model was identified, further training 1000 times resulted in a mean testing area under the curve of 0.8891 (95% CI 0.8858, 0.8924).

Conclusions

Identification of a high-volume PDA shunt is possible with high accuracy using logistic regression modeling. Further work should focus on identification of moderate-volume shunts and correlation with clinical outcomes.

Le texte complet de cet article est disponible en PDF.

Keywords : neonatal hemodynamics, shunt volume, targeted neonatal echocardiography

Abbreviations : AI, AUC, BP, BPD, DBP, GA, HR, hsPDA, MBP, PDA, RCT, SBP, TNE


Plan


© 2025  Elsevier Inc. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 291

Article 114965- avril 2026 Retour au numéro
Article précédent Article précédent
  • General Movement Optimality Score-Revised (GMOS-R) with General Population-Based Percentile Ranks
  • Natasha Amery, Caroline F. Alexander, Alison T. Salt, Sarah E. Hall, Catherine Elliott, Catherine Morgan, Alicia J. Spittle, Jane Valentine
| Article suivant Article suivant
  • Increase in Necrotizing Enterocolitis with Cessation of Bifidobacterium longum ssp. infantis Administration in Very Low Birthweight Infants: A Single Center Retrospective Cohort Study
  • Leigh Selesner, Madeline Hedges, Rachel Pung, Cortnie Vaughn, Adam Burns, Molly Aloia, Justin Henson, Joseph Tobias, Amy Olyaei, Samantha Nizich, Kevin Swift, Amirali Veshagh, Sarah F. Andres, Elizabeth Fialkowski, Brian K. Jordan, Brian Scottoline

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.