S'abonner

Comparing the Vitreous Floaters Functional Questionnaire to the VFQ-25 in Vision Degrading Myodesopsia from Vitreous Floaters - 05/05/26

Doi : 10.1016/j.ajo.2026.02.027 
J. Sebag 1, 2, , Justin H. Nguyen 1, Kenneth M.P. Yee 1, Ashley Burchfield 1, Fei Yu 3, Alfredo A. Sadun 4
1 From VMR Consulting (J.S., J.H.N., K.M.P.Y., A.B.), Huntington Beach, California, USA 
2 Doheny Eye Institute (J.S.), UCLA, Pasadena, California, USA 
3 Center for Community Outreach and Policy (F.Y.), Department of Ophthalmology, Stein and Doheny Eye Institutes, California, USA 
4 David Geffen School of Medicine (A.A.S.), UCLA, Los Angeles, California, USA 

Inquiries to J. Sebag, VMR Consulting, Inc. Huntington Beach, California 92647, USA. VMR Consulting Inc. Huntington Beach California 92647 USA

HIGHLIGHTS

The Vitreous Floaters Functional Questionnaire (VFFQ) is a validated PRO that quantifies the impact of vision degrading myodesopsia from vitreous floaters on visual quality-of-life.
The VFFQ correlates strongly with vitreous density, measured by quantitative ultrasonography, and contrast sensitivity.
193 subjects with floaters completed both the VFFQ and the NEI VFQ-25.
The dynamic range (potential = 0 to 100) of the VFFQ was 22 to 92, which was greater than the VFQ-25 (64 to 100).
Patients who chose observation had considerably higher VFFQ composite scores than those who chose limited refractive vitrectomy (73.0 ± 9.9 vs. 53.9 ± 11.4; p < .0001), but the VFQ-25 composite scores were similar in both groups (79.1 ± 6.0 vs. 77.3 ± 5.1; P = .053).
VFFQ had a better predictive value than VFQ-25 in identifying patients who elected limited refractive vitrectomy as well as those electing observation.
After limited refractive vitrectomy, the VFFQ improved 72.2 ± 3.2% ( P < .001), while VFQ-25 only improved 7.4% ± 1.8% (average of post-op months 6, 12, 24, and 36).

Le texte complet de cet article est disponible en PDF.

Résumé

Purpose

To compare the Vitreous Floater Functional Questionnaire (VFFQ-23) to the NEI Visual Function Questionnaire (VFQ-25) in patients with vision degrading myodesopsia (VDM) from vitreous floaters. Composite scores for each questionnaire were compared in asymptomatic controls, patients who chose observation (OBS), and those electing vitrectomy. The impact of limited refractive vitrectomy (LRV) on the composite scores of each questionnaire was determined.

Design

A retrospective study comparing questionnaire correlations with management choice (OBS or LRV), and a prospective, non-randomized, interventional case series.

Subjects

74 subjects were asymptomatic controls; 193 subjects had bilateral floaters: 139 chose OBS, 54 elected LRV surgery.

Methods

Patients complaining of bilateral “ floaters ” completed the VFFQ-23 and VFQ-25 questionnaires and composite scores were correlated with visual acuity (VA), contrast sensitivity (CS), quantitative ultrasonography (QUS), and management choice (OBS or LRV). LRV was performed in 54 patients, and all tests were repeated at 6, 12, 24, and 36 months post-operatively.

Main Outcome Measures

VFFQ-23 (0 to 100), NEI VFQ-25 (0 to 100), VA (Snellen), CS (Freiburg Acuity Contrast Test), QUS (AU), predictive value, Receiver Operator Characteristic areas under the curve (AUC), decision curve analysis (DCA).

Results

VFFQ-23 correlated with CS ( R = −.619; P < .0001) and QUS ( R = −.632; P < .0001). VFFQ-23 correctly identified 89% of patients who chose LRV with a positive predictive value of 73.8% for LRV and 95.3% for OBS, while VFQ-25 had a positive predictive value of only 60%; VFFQ-23 AUC = 0.923, VFQ-25 AUC = 0.570. DCA demonstrated a higher net benefit for VFFQ-23 than both “Treat All” and “Treat None” strategies. After LRV, VFFQ-23 improved 72.2% ± 3.2% ( P < .001), while VFQ-25 only improved 7.4% ± 1.8%, ( P < .001). The difference-in-differences before and after surgery between VFFQ-23 and VFQ-25 was 31.9 ± 12.0 ( P < .001).

Conclusions

In patients with vitreous floaters, the VFFQ-23 correlated with CS and QUS. VFFQ-23 was a better predictor of patient management choice (OBS or LRV) and was more sensitive to post-operative improvement than VFQ-25. VFFQ-23 superiority to VFQ-25 was confirmed by DCA. Thus, VFFQ-23 may be more useful in assessing the subjective impact of floaters on visual quality-of-life, in screening/triage, and as an outcome measure of current and future therapies for VDM.

Le texte complet de cet article est disponible en PDF.

Plan


  Supplemental Material available at AJO.com .
 Presented in part at the annual meeting of the Association for Research in Vision and Ophthalmology, New Orleans, Louisiana, April 2023


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 286

P. 81-89 - juin 2026 Retour au numéro
Article précédent Article précédent
  • Progression in X-Linked Retinoschisis: A Longitudinal Study Defining Quantitative Biomarkers and Their Implications for Gene Therapy
  • Xing Wei, Hui Li, Wuyi Li, Yunyu Zhou, Yamei Li, Yue Liu, Dingding Zhang, Ruifang Sui
| Article suivant Article suivant
  • Defocus Incorporated Multiple Segments (DIMS) Spectacle Lenses Versus Single-Vision Lenses for Pediatric Myopia: A Systematic Review and Meta-Analysis
  • YOUSEF MESAED AL-SHAMMARI, SAUD ABDULLAH ALKANDARI, REEM MESAED AL-SHAMMARI, MOHAMMED AL-MAHDI  AL-KURDI, FAISAL ALJASSAR

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.