S'abonner

Reduced-Dose Computed Tomography vs Multiview Radiographs in Pediatric Foreign Body Aspiration - 22/05/26

Doi : 10.1016/j.jpeds.2026.115030 
Ruoying Li, BS 1, , Jan Niec, MD 2, Shilin Zhao, PhD 3, Jared Grice, DMP 2, Katharyn D. Cassella, DO 2, Lindsey Johnstone, MD 4, Michele Walsh, MD 5, Marta Schulman, MD 4, Harold N. Lovvorn, MD 6
1 Vanderbilt University School of Medicine, Nashville, TN 
2 Department of Radiology, Vanderbilt University Medical Center, Nashville, TN 
3 Department of Biostatistics, Vanderbilt University Medical Center, Nashville, TN 
4 Department of Pediatric Radiology, Monroe Carell Jr. Children's Hospital at Vanderbilt, Nashville, TN 
5 Division of Pediatric Emergency Medicine, Monroe Carell Jr. Children's Hospital at Vanderbilt, Nashville, TN 
6 Department of Pediatric Surgery, Monroe Carell Jr. Children's Hospital at Vanderbilt, Nashville, TN 

Reprint requests: Ruoying Li, BS, Vanderbilt University School of Medicine, 2209 Garland Avenue, Nashville, TN 37212. Vanderbilt University School of Medicine 2209 Garland Avenue Nashville TN 37212

Abstract

Objective

To compare the overall safety, efficacy, and resource utilization of ultra-low-dose computed tomography (ULDCT) with multiview chest x-ray (CXR) in children presenting with suspected foreign body aspiration (FBA).

Study design

A single-center, retrospective chart review was conducted for patients ≤17 years of age with concern for FBA and presenting between January 1, 2018, and July 31, 2024. Computed tomography (CT) studies were categorized as standard, low, and ultra-low dose, based on reported CT dose index volume. Measures of diagnostic performance, estimated effective doses, and total variable costs per patient encounter were compared between imaging modalities.

Results

Three hundred thirty patients were evaluated for FBA with CXR only (n = 171), CT only (n = 47), or both modalities (n = 112). One hundred thirty-two patients underwent bronchoscopy with 107 foreign bodies discovered. Negative bronchoscopy rates ranged from 11% (n = 1) in patients evaluated with CT only to 21% (n = 18) in patients evaluated with CXR only. Seven patients evaluated with CXR only were later found to have missed airway foreign bodies. The sensitivity and specificity of ULDCT for tracheobronchial foreign bodies were 100%, respectively. Sensitivity and specificity were 74% and 83% for two-view CXR and 82% and 67% for four-view CXR. Mean effective dose of ULDCT was 0.18 mSv higher than four-view CXR ( P < .001). Median total variable costs were similar among patients initially evaluated with CXR and CT ( P = .21).

Conclusions

Reduced-dose CT showed greater sensitivity and specificity than CXR to diagnose FBA and can be delivered without a clinically significant increase in radiation exposure or hospital expenditure.

Le texte complet de cet article est disponible en PDF.

Abbreviation : CT, CXR, ED, FBA, LDCT, SDCT, ULDCT


Plan


© 2026  The Author(s). Publié par Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Vol 293

Article 115030- juin 2026 Retour au numéro
Article précédent Article précédent
  • Preventing Postvaccination Presyncope and Syncope in Adolescents: A Randomized Controlled Trial of a Clinic-Based Intervention
  • Michael J. Smith, Theresa A. Harrington, Richard J. Chung, Wes Rountree, Marek S. Poniewierski, Rachel L. Spreng, Karen R. Broder, Andrew Kroger, Michael M. McNeil, Paige Marquez, Emmanuel B. Walter
| Article suivant Article suivant
  • Effects of Extracorporeal Life Support Volume on Neonatal Mortality in Congenital Diaphragmatic Hernia: A Retrospective Cohort Study
  • Yigit S. Guner, Alice Martino, Andreina Giron, Zoe Flyer, Karna Murthy, Matteo Di Nardo, John Schomberg, Theresa R. Grover, J.D. Hammond, Peter T. Yu, Laura F. Goodman, Sharada H. Gowda, Matthew T. Harting, Tim Jancelewicz, Danh V. Nguyen

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.