S'abonner

Urétéroscope flexible à usage unique 6,3 Fr : vers la fin du pré-stenting ? - 14/06/26

6.3 Fr flexible ureteroscope: A step toward eliminating the need for pre-stenting?

Doi : 10.1016/j.fpurol.2026.04.005 
M. Corrales a, , e, h , M. Chicaud b, f, S. Kutchukian c, f, F. Panthier d, e, f, g, h
a Service d’urologie, CHU Gabriel-Montpied, 58, rue Montalembert, 63000 Clermont-Ferrand, France 
b Department of Urology, Limoges University Hospital, 2, avenue Martin Luther King, 87000 Limoges, France 
c Department of Urology, CHU de Nîmes, 4, rue du Professeur-Robert-Debré, 30900 Nîmes, France 
d Department of Urology, hôpital Tenon, Assistance publique–Hôpitaux de Paris, Sorbonne université, 4, rue de la Chine, 75020 Paris, France 
e Progressive Endourological Association for Research and Leading Solutions (PEARLS group), Paris, France 
f PIMM, UMR 8006 CNRS-Arts et Métiers ParisTech, 151, boulevard de l’Hôpital, 75013 Paris, France 
g  PIMM Lab Arts et Métiers ParisTech, Endolase Lab, GRC n o  20-Sorbonne université, 75020 Paris, France  
h Endourology Technology Section of European Association of Urology (EAU), Arnhem, Pays-Bas 

Auteur correspondant : Service d’urologie, CHU Gabriel-Montpied, 58, rue Montalembert, 63000 Clermont-Ferrand, France. Service d’urologie, CHU Gabriel-Montpied 58, rue Montalembert Clermont-Ferrand 63000 France
Sous presse. Épreuves corrigées par l'auteur. Disponible en ligne depuis le Sunday 14 June 2026

Résumé

Introduction

L’évolution des urétéroscope flexible à usage unique (fURS) vers des modèles de petit calibre, notamment le 6,3 Fr, permet la réalisation d’une urétéroscopie première sans pré-stenting, avec une diminution du nombre d’interventions, des complications et des coûts. Cette étude évaluait la faisabilité et la sécurité d’utilisation du 6,3 Fr avec comme critères de jugement l’intubation urétérale, le temps opératoire, le taux de sans fragment résiduel (SFR) et les complications.

Méthodes

Une recherche systématique de la littérature a été effectuée dans les bases de données MEDLINE, Scopus et Mary Ann Liebert jusqu’en février 2026, afin d’identifier les essais cliniques, séries de cas et résumés utilisant des fURS 6,3 Fr. Les études utilisant des urétéroscopes de plus grand calibre ou des procédures non endoscopiques ont été exclues. Les données ont été synthétisées de manière narrative conformément aux recommandations PRISMA.

Résultats

Cinq études ont été incluses, dont quatre comparatives avec des fURS de 7,5 Fr. Le taux de succès d’intubation première de l’orifice urétéral variait de 95 à 100 %, atteignant 100 % avec les fURS de 6,3 Fr également chez les patients sans pré-stenting. Les temps opératoires étaient comparables entre les études, sauf dans un essai où le fURS de 6,3 Fr présentait des temps significativement plus courts (50,5 vs 60,5 min) sans utilisation de gaine d’accès urétérale. Le taux de SFR dépassait 80 % dans toutes les études, l’une d’entre elles rapportant des taux significativement plus élevés pour le fURS de 6,3 Fr. Aucune complication majeure n’a été observée ; la plupart étaient de grade I–II selon la classification Clavien-Dindo.

Conclusions

Le fURS de 6,3 Fr permet une urétéroscopie sûre et efficace, avec un taux de succès de près de 100 % d’accès urétéral premier sans pré-stenting, une absence de plaie urétérale et un taux de SFR de plus de 80 %.

Le texte complet de cet article est disponible en PDF.

Summary

Introduction

An ideal flexible ureteroscope (FURS) should match the ureter's anatomy. Advances in ultra-thin, single-use FURS, including the 6.3 Fr models, allow primary ureteroscopy without pre-stenting, potentially reducing interventions, complications, and healthcare costs. This study evaluates the feasibility and safety of the 6.3 Fr FURS, focusing on ureteral access, operative time, stone-free rate (SFR), and complications.

Methods

A systematic literature search of MEDLINE, Scopus, and Mary Ann Liebert databases was performed up to February 2026, identifying clinical trials, case series, and abstracts using 6.3 Fr FURS. Studies using larger ureteroscopes or non-endoscopic procedures were excluded. Data were synthesized narratively following PRISMA guidelines.

Results

Five studies were included, four of which were comparative with 7.5 Fr FURS. Primary ureteral orifice intubation success ranged from 95–100%, achieving 100% with 6.3 Fr FURS even without pre-stenting. Operative times were similar across studies, except in one trial where the 6.3 Fr FURS had significantly shorter times (50.5 vs. 60.5 min) with no ureteral access sheath use. SFR exceeded 80% in all studies, with one reporting significantly higher rates for 6.3 Fr FURS. No major complications were observed; most were Clavien-Dindo grade I–II.

Conclusions

The 6.3 Fr FURS enables safe, effective primary ureteroscopy without pre-stenting, offering high ureteral access success, efficient irrigation, minimal mechanical trauma, and excellent SFR.

Le texte complet de cet article est disponible en PDF.

Mots clés : Urétéroscope, 6,3 Fr, Calculs, Stent, Double J

Keywords : Ureteroscopy, 6.3 Fr, Stones, Stent, Double J


Plan


© 2026  Elsevier Masson SAS. Tous droits réservés.
Ajouter à ma bibliothèque Retirer de ma bibliothèque Imprimer
Export

    Export citations

  • Fichier

  • Contenu

Bienvenue sur EM-consulte, la référence des professionnels de santé.
L’accès au texte intégral de cet article nécessite un abonnement.

Déjà abonné à cette revue ?

Elsevier s'engage à rendre ses eBooks accessibles et à se conformer aux lois applicables. Compte tenu de notre vaste bibliothèque de titres, il existe des cas où rendre un livre électronique entièrement accessible présente des défis uniques et l'inclusion de fonctionnalités complètes pourrait transformer sa nature au point de ne plus servir son objectif principal ou d'entraîner un fardeau disproportionné pour l'éditeur. Par conséquent, l'accessibilité de cet eBook peut être limitée. Voir plus

Mon compte


Plateformes Elsevier Masson

Déclaration CNIL

EM-CONSULTE.COM est déclaré à la CNIL, déclaration n° 1286925.

En application de la loi nº78-17 du 6 janvier 1978 relative à l'informatique, aux fichiers et aux libertés, vous disposez des droits d'opposition (art.26 de la loi), d'accès (art.34 à 38 de la loi), et de rectification (art.36 de la loi) des données vous concernant. Ainsi, vous pouvez exiger que soient rectifiées, complétées, clarifiées, mises à jour ou effacées les informations vous concernant qui sont inexactes, incomplètes, équivoques, périmées ou dont la collecte ou l'utilisation ou la conservation est interdite.
Les informations personnelles concernant les visiteurs de notre site, y compris leur identité, sont confidentielles.
Le responsable du site s'engage sur l'honneur à respecter les conditions légales de confidentialité applicables en France et à ne pas divulguer ces informations à des tiers.


Tout le contenu de ce site: Copyright © 2026 Elsevier, ses concédants de licence et ses contributeurs. Tout les droits sont réservés, y compris ceux relatifs à l'exploration de textes et de données, a la formation en IA et aux technologies similaires. Pour tout contenu en libre accès, les conditions de licence Creative Commons s'appliquent.